Bids Are invited for Custom Bid For Services - Electrical Rewiring Of Quarters And Block Wiring And Street Lighting Fitting Of High Mast Tower Of Different Colonies And Feeder Pillar Work And Transformer Cable Jointing Kit Termination Kit Work Etc Of
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - Electrical Rewiring Of Quarters And Block Wiring And Street Lighting Fitting Of High Mast Tower Of Different Colonies And Feeder Pillar Work And Transformer Cable Jointing Kit Termination Kit Work Etc Of Majri Area Under M.. - Dismantling The Existing Light, Fan, Bell, Clock, Independent Plug Point, Wiring Including Circuit Mains Of All Types Along With Accessories Etc. Complete As Per Specification No. Wg-Dm/Pw ,Sor 1-8-1 , Point Wiring For Light/Bell/Exhaust Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw ,Sor 1-7-18 , Point Wiring For Light/Bell/Exhaust Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw (Extra 50% For Stair Case Wiring) ,Sor 1-7-18 , Wiring For Plug On Board With Switch Socket Surface/Concealed Type, Copper Wiring And Earthing And With Modular Accessories As Per Specification No. Wg-Pw/Cw ,Sor 1-7-25 , Point Wiring For Ceiling Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw ,Sor 1-7-19 , Point Wiring For Independent Plug In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw ,Sor 1-7-20 , Supplying And Erecting Modular Type (Two Module) Electronic Dimmer 600/650W On Provided Plate And Box With Wiring Connections Complete. ,Sor 1-6-21 , Supplying And Erecting Modular Type Switch 6A/10A On Provided Plate And Box With Wiring Connections Complete. ,Sor 1-6-1 , Supplying And Erecting Modular Type 3 Pin 6A Multi Socket With Safety Shutter On Provided Plate And Box With Wiring Connections Complete. ,Sor 1-6-10 , Supplying And Erecting Modular Type Switch 16A On Provided Plate And Box With Wiring Connections Complete. ,Sor 1-6-2 , Supplying And Erecting Modular Type 3 Pin 6/16A Multi Socket With Safety Shutter On Provided Plate And Box With Wiring Connections Complete. ,Sor 1-6-11 , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 2 Module Complete. ,Sor 1-6-27 , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Module Complete. ,Sor 1-6-28 , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module Complete. ,Sor 1-6-32 , Supplying And Erecting Modular Type Buzzer 220/250V On Provided Plate And Box With Wiring Connections Complete. ,Sor 1-6-19 , Supplying & Erecting Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw ,Sor 1-3-1 , Supplying & Erecting Mains With 3X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw ,Sor 1-3-6 , Supplying & Erecting Mains With 3X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw ,Sor 1-3-7 , Supplying & Erecting Mains With 3X6 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw ,Sor 1-3-8 , Supplying And Erecting Pvc Trunking (Pvc Casing-N-Capping) Of Size 32Mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. ,Sor 1-2-8 , Supplying, Erecting & Marking Fp Mcb 63A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb ,Sor 5-3-13 , Supplying, Erecting & Marking Dp Mcb 63A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb ,Sor 5-3-9 , Supplying, Erecting & Commissioning 2 Pole Rccb 63A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb. ,Sor 5-6-3 , Supplying, Erecting & Marking Sp Mcb 16A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb ,Sor 5-3-3 , Supplying, Erecting & Marking Sp Mcb 25A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb ,Sor 5-3-3 , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Spmcb Of 8 Ways/Phase (24 Poles), With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame (Horizontal Busbar Type) As Per Specification No. Sw-Mcbdb. ,Sor 5-4-2 , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Spmcb Of 4 Ways/Phase (12 Poles), With Door, 1.2Mm Thickness, Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame (Horizontal Busbar Type) As Per Specification No. Sw-Mcbdb. ,Sor 5-4-1 , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 2 Ways (2 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame As Per Specification No. Sw-Mcbdb ,Sor 5-4-7 , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 4 Ways (4 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame As Per Specification No. Sw-Mcbdb ,Sor 5-4-8 , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 6 Ways (6 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame As Per Specification No. Sw-Mcbdb ,Sor 5-4-9 , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable, 1100 V 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al ,Sor 7-1-29 , Supplying, Installing And Testing Earthing With Galvanised Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Accessories Of Gi Materials & Recording The Results As Per Specification No. Ea-Ep ,Sor 9-1-1 , Supplying And Erecting Gi Earth Conductor Of Required Sizes Used For Earthing Or Any Other Purposes On Wall With Necessary Gi Cl S Fixed On Wall/Cable/ Conduit With Screws Complete. ,Sor 9-2-5 , Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. ,Sor 2-10-2 , Supplying, Erecting & Marking Sp Mcb 32A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb ,Sor 5-3-3 , Supplying, Erecting & Commissioning 2 Pole Rccb 40A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb. ,Sor 5-6-2 , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable, 1100 V 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al ,Sor 7-1-28 , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, Complete. ,Sor 7-6-9 , Ac Mcb Box 25 A With 25A 3 Pin Top (Non Sor) ,Sor Non Sor , Providing & Erecting 4Pole Mccb, 415V, 200A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (20% Extra For 4 Pole) ,Sor 5-5-3 , Supplying And Erecting Din Type Hrc Fuse Cartridge 440V, 200A ,Sor 5-10-29 , Flood Light;Led,200W (Code 4600031483) (Maintenance Of High Mast Towers Of Colony) Warranty 3 Year Specifications As Per Is (As Per Gem Contract) ,Sor Non Sor , Flood Light;Led,400W (Code 4600016329) (Maintenance Of High Mast Towers Of Colony) Warranty 3 Year Specifications As Per Is (As Per Sap Rate) ,Sor Non Sor , Flood Light;Led,300W (Code 4600016330) (Maintenance Of High Mast Towers Of Colony) Warranty 3 Year Specifications As Per Is (As Per Sap Rate) ,Sor Non Sor , Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K,Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Odf/Sl. (As Per Sap Rate) (Code 4600016631) ,Sor Non Sor , Supplying And Erecting Integrated Led Street Light Fitting 100-110W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver Complete With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Sl. (As Per Sap Rate) (Code 4600016647) ,Sor Non Sor , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable, 1100 V 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al ,Sor 7-1-28 , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable, 1100 V 3½ Core 95 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/A ,Sor 7-1-19 , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 75 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, Complete. ,Sor 7-6-10 , Supplying , Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable , 11 Kv(E), 3 X 70 Sq. Mm. Aluminium Conductor Laid In Provided Trench / Pipe As Per Specification No. Cb-Ht ,Sor 7-3-1 , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable, 1100 V 3½ Core 120 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/A ,Sor 7-1-20 , Supplying , Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 11 Kv(E), 3 X 95 Sq. Mm. Aluminium Conductor Laid In Provided Trench / Pipe As Per Specification No. Cb-Ht ,Sor 7-3-2 , Supplying&Erecting Crimping Type Aluminium Lugs For Cable 95 Sqmm Complete As Per Specification No. Cb-Cl/Al ,Sor 7-10-6 , Supplying&Erecting Crimping Type Aluminium Lugs For Cable 70 Sqmm Complete As Per Specification No. Cb-Cl/Al ,Sor 7-10-5 , Supplying & Erecting Crimping Type Aluminium Lugs For Cable 120 Sq Mm Complete As Per Specification No. Cb-Cl/Al ,Sor 7-10-7 , Supplying & Erecting Crimping Type Copper Lugs For Cable 70 Sq Mm Completeas Per Specification No. Cb-Cl/Cu ,Sor 7-9-5 , Supplying & Erecting Crimping Type Copper Lugs For Cable 95 Sq Mm Complete As Per Specification No. Cb-Cl/Cu ,Sor 7-9-6 , Supplying & Erecting Single Compression Type Brass Cable Glands For 3½ Core 120 Sq Mm Cable As Per Specification No. Cb-Gl ,Sor 7-7-8 , Supplying & Erecting Single Compression Type Brass Cable Glands For 3½ Core 70 Sq Mm Cable As Per Specification No. Cb-Gl ,Sor 7-7-6 , Supplying & Erecting Single Compression Type Brass Cable Glands For 3½ Core 95 Sq Mm Cable As Per Specification No. Cb-Gl ,Sor 7-7-7 , Providing And Erecting Heat Shrinkable Outdoor Termination Kit For 11 Kv (E)Xlpe Ht Cable 3 X Up To 70 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt/Ht ,Sor 7-5-5 , Providing And Erecting Heat Shrinkable Outdoor Termination Kit For 11 Kv (E)Xlpe Ht Cable 3 X Up To 50 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt/Ht ,Sor 7-5-5 , Providing & Erecting Floor/Wall Mounting, Mccb Panel Board, With Door, Suitable For 4 Pole Incoming 400A, 8 Ways 4 Pole Outgoing, Up To 100A Mccbs On Iron Frame, As Per Specification No. Sw-Mccbpb. (Excluding Mccbs) ,Sor 5-7-9 , Providing & Erecting Floor/Wall Mounting, Mccb Panel Board, With Door, Suitable For 4 Pole Incoming 400 A, 6 Ways 4 Pole Outgoing, Up To 100A Mccbs On Iron Frame, As Per Specification No. Sw-Mccbpb. (Excluding Mccbs) ,Sor 5-7-8 , Providing & Erecting Floor/Wall Mounting, Mccb Panel Board, With Door, Suitable For 4 Pole Incoming 250A, 12 Ways 4 Pole Outgoing, Up To 100A Mccbs On Iron Frame, As Per Specification No. Sw-Mccbpb. (Excluding Mccbs) ,Sor 5-7-5 , Providing And Erecting Heat Shrinkable Outdoor Termination Kit For 11 Kv (E)Xlpe Ht Cable 3 X Up To 95 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt/Ht ,Sor 7-5-5 , Providing & Erecting 4 Pole Mccb 415V, 630A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (As Per Note For Use Of 4 Pole Mccb Add 20% In Rate) ,Sor 5-5-7 , Providing & Erecting 4 Pole Mccb 415V, 400A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/ Uv/ Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure /Panel As Per Specification No. Sw-Mccb (As Per Note For Use Of 4 Pole Mccb Add 20% In Rate) ,Sor 5-5-6 , Providing & Erecting 4 Pole Mccb 415V, 250A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu) Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (As Per Note For Use Of 4 Pole Mccb Add 20% In Rate) ,Sor 5-5-4 , Providing & Erecting 4 Pole Mccb, 415V, 160A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (As Per Note For Use Of 4 Pole Mccb Add 20% In Rate) ,Sor 5-5-2 , Supplying And Erecting Panel Mounting Type Digital Ammeter Having Three And Half Digit Led Display, External Ct Operated, Calibrated For Suitable To Operate On 500V, 0 To 1000A Having Accuracy Class Of 0.5, Ac Supply With Necessary Pvc Wire Leads And Lugs And Mounting Hardware On Provided Panel Complete With Calibration Certificate From Manufacturer. ,Sor 6-5-7 , Supplying And Erecting Panel Mounting Type Digital Voltmeter Having Three And Half Digit Led Display, Calibrated For 0 To 750V Ac Suitable To Operate On 500V Having Accuracy Class Of 0.5, Ac Supply With Necessary Pvc Wire Leads And Lugs And Mounting Hardware On Provided Panel Complete With Calibration Certificate From Manufacturer. ,Sor 6-5-8 , Supplying, Erecting, Testing & Commisioning Lt Current Transformer With Bar Primary 50/5 To 1000/5 Ratio With 15 Va Burden Erected In Provided Crca Box Duly Secured With Insulating Materials Connected To The Meter With Test Certificates. ,Sor 6-7-2 , Supplying And Erecting Selector Switch Suitable For Voltmeter/Ammeter For 3 Phase Ac Supply 500V, 50Hz, On Provided Box/Panel And Duly Connecting With Necessary Pvc Wire Leads And Lugs. ,Sor 6-7-1 , Supplying And Erecting Fuse Base For Din Type Hrc Fuse Cartridge 500V, 200A ,Sor 5-10-35 , Supplying And Erecting Fuse Base For Din Type Hrc Fuse Cartridge 500V, 250A ,Sor 5-10-35 , Supplying And Erecting Din Type Hrc Fuse Cartridge 500V, 250A ,Sor 5-10-30 , Supplying And Erecting Fuse Base For Din Type Hrc Fuse Cartridge 500V, 300A ,Sor 5-10-36 , Supplying And Erecting Din Type Hrc Fuse Cartridge 500V, 315A ,Sor 5-10-31 , Supplying & Erecting Led Type Indicating Pilot L With Led Colours Red / Yellow / Green, 230 / 250V On Provided Box / Panel With Necessary Material, Wiring & Connections Etc. ,Sor 6-7-5 , Providing & Erecting Incoming And Outgoing Cable Alleys Suitable For Mccb Panel Board With Door, 250A Incoming And 12 Way Outgoing Or 400A Incoming And 6/8 Way Outgoing Made From Crca Sheet 1.6 Mm Thick Duly Powder Coated And Having Vertical Insulated Partition For Shielding Between The Shared Face Of Cableway And Db Complete. ,Sor 5-7-15 , Providing & Erecting Incoming And Outgoing Cable Alleys Suitable For Mccb Panel Board With Door, 400A Incoming And 12 Way Outgoing Made From Crca Sheet 1.6 Mm Thick Duly Powder Coated And Having Vertical Insulated Partition For Shielding Between The Shared Face Of Cableway And Db Complete. ,Sor 5-7-16 , Providing & Erecting Epoxy Straight Through Joint Outdoor/Indoor For Lt Xlpe Armoured Cable 70 To 95 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt/Lt ,Sor 7-4-3
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW ,SOR 1-8-1 | Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW ,SOR 1-8-1 |
| 2 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW ,SOR 1-7-18 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW ,SOR 1-7-18 |
| 3 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW (Extra 50% for Stair case wiring) ,SOR 1-7-18 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW (Extra 50% for Stair case wiring) ,SOR 1-7-18 |
| 4 | Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WG-PW/CW ,SOR 1-7-25 | Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WG-PW/CW ,SOR 1-7-25 |
| 5 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW ,SOR 1-7-19 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW ,SOR 1-7-19 |
| 6 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW ,SOR 1-7-20 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW ,SOR 1-7-20 |
| 7 | Supplying and erecting modular type (two module) electronic dimmer 600/650W on provided plate and box with wiring connections complete. ,SOR 1-6-21 | Supplying and erecting modular type (two module) electronic dimmer 600/650W on provided plate and box with wiring connections complete. ,SOR 1-6-21 |
| 8 | Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete. ,SOR 1-6-1 | Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete. ,SOR 1-6-1 |
| 9 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete. ,SOR 1-6-10 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete. ,SOR 1-6-10 |
| 10 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete. ,SOR 1-6-2 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete. ,SOR 1-6-2 |
| 11 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. ,SOR 1-6-11 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. ,SOR 1-6-11 |
| 12 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete. ,SOR 1-6-27 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete. ,SOR 1-6-27 |
| 13 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module complete. ,SOR 1-6-28 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module complete. ,SOR 1-6-28 |
| 14 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module complete. ,SOR 1-6-32 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module complete. ,SOR 1-6-32 |
| 15 | Supplying and erecting modular type buzzer 220/250V on provided plate and box with wiring connections complete. ,SOR 1-6-19 | Supplying and erecting modular type buzzer 220/250V on provided plate and box with wiring connections complete. ,SOR 1-6-19 |
| 16 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-1 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-1 |
| 17 | Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-6 | Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-6 |
| 18 | Supplying & erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-7 | Supplying & erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-7 |
| 19 | Supplying & erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-8 | Supplying & erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW ,SOR 1-3-8 |
| 20 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification no. WG-MA/CON. ,SOR 1-2-8 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification no. WG-MA/CON. ,SOR 1-2-8 |
| 21 | Supplying, erecting & marking FP MCB 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-13 | Supplying, erecting & marking FP MCB 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-13 |
| 22 | Supplying, erecting & marking DP MCB 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-9 | Supplying, erecting & marking DP MCB 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-9 |
| 23 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. ,SOR 5-6-3 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. ,SOR 5-6-3 |
| 24 | Supplying, erecting & marking SP MCB 16A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-3 | Supplying, erecting & marking SP MCB 16A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-3 |
| 25 | Supplying, erecting & marking SP MCB 25A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-3 | Supplying, erecting & marking SP MCB 25A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-3 |
| 26 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways/phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. ,SOR 5-4-2 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways/phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. ,SOR 5-4-2 |
| 27 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. ,SOR 5-4-1 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. ,SOR 5-4-1 |
| 28 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB ,SOR 5-4-7 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB ,SOR 5-4-7 |
| 29 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 4 ways (4 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB ,SOR 5-4-8 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 4 ways (4 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB ,SOR 5-4-8 |
| 30 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB ,SOR 5-4-9 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB ,SOR 5-4-9 |
| 31 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ,SOR 7-1-29 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ,SOR 7-1-29 |
| 32 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP ,SOR 9-1-1 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP ,SOR 9-1-1 |
| 33 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. ,SOR 9-2-5 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. ,SOR 9-2-5 |
| 34 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. ,SOR 2-10-2 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. ,SOR 2-10-2 |
| 35 | Supplying, erecting & marking SP MCB 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-3 | Supplying, erecting & marking SP MCB 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB ,SOR 5-3-3 |
| 36 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. ,SOR 5-6-2 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. ,SOR 5-6-2 |
| 37 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ,SOR 7-1-28 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ,SOR 7-1-28 |
| 38 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. ,SOR 7-6-9 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. ,SOR 7-6-9 |
| 39 | AC MCB box 25 A with 25A 3 pin top (non SOR) ,SOR NON SOR | AC MCB box 25 A with 25A 3 pin top (non SOR) ,SOR NON SOR |
| 40 | Providing & erecting 4Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (20% extra for 4 pole) ,SOR 5-5-3 | Providing & erecting 4Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (20% extra for 4 pole) ,SOR 5-5-3 |
| 41 | Supplying and erecting DIN Type HRC Fuse cartridge 440V, 200A ,SOR 5-10-29 | Supplying and erecting DIN Type HRC Fuse cartridge 440V, 200A ,SOR 5-10-29 |
| 42 | Flood Light;LED,200W (code 4600031483) (maintenance of High Mast towers of colony) Warranty 3 Year specifications as per IS (As per GEM contract) ,SOR NON SOR | Flood Light;LED,200W (code 4600031483) (maintenance of High Mast towers of colony) Warranty 3 Year specifications as per IS (As per GEM contract) ,SOR NON SOR |
| 43 | Flood Light;LED,400W (code 4600016329) (maintenance of High Mast towers of colony) Warranty 3 Year specifications as per IS (As per SAP rate) ,SOR NON SOR | Flood Light;LED,400W (code 4600016329) (maintenance of High Mast towers of colony) Warranty 3 Year specifications as per IS (As per SAP rate) ,SOR NON SOR |
| 44 | Flood Light;LED,300W (code 4600016330) (maintenance of High Mast towers of colony) Warranty 3 Year specifications as per IS (As per SAP rate) ,SOR NON SOR | Flood Light;LED,300W (code 4600016330) (maintenance of High Mast towers of colony) Warranty 3 Year specifications as per IS (As per SAP rate) ,SOR NON SOR |
| 45 | Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. (As per SAP rate) (code 4600016631) ,SOR NON SOR | Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. (As per SAP rate) (code 4600016631) ,SOR NON SOR |
| 46 | Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG ODF/SL. (As per SAP rate) (code 4600016647) ,SOR NON SOR | Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG ODF/SL. (As per SAP rate) (code 4600016647) ,SOR NON SOR |
| 47 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ,SOR 7-1-28 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ,SOR 7-1-28 |
| 48 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/A ,SOR 7-1-19 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/A ,SOR 7-1-19 |
| 49 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. ,SOR 7-6-10 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. ,SOR 7-6-10 |
| 50 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable , 11 kV(E), 3 x 70 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT ,SOR 7-3-1 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable , 11 kV(E), 3 x 70 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT ,SOR 7-3-1 |
| 51 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/A ,SOR 7-1-20 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/A ,SOR 7-1-20 |
| 52 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT ,SOR 7-3-2 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT ,SOR 7-3-2 |
| 53 | Supplying&erecting crimping type aluminium lugs for cable 95 sqmm complete as per specification No. CB-CL/AL ,SOR 7-10-6 | Supplying&erecting crimping type aluminium lugs for cable 95 sqmm complete as per specification No. CB-CL/AL ,SOR 7-10-6 |
| 54 | Supplying&erecting crimping type aluminium lugs for cable 70 sqmm complete as per specification No. CB-CL/AL ,SOR 7-10-5 | Supplying&erecting crimping type aluminium lugs for cable 70 sqmm complete as per specification No. CB-CL/AL ,SOR 7-10-5 |
| 55 | Supplying & erecting crimping type aluminium lugs for cable 120 sq mm complete as per specification No. CB-CL/AL ,SOR 7-10-7 | Supplying & erecting crimping type aluminium lugs for cable 120 sq mm complete as per specification No. CB-CL/AL ,SOR 7-10-7 |
| 56 | Supplying & erecting crimping type copper lugs for cable 70 sq mm completeas per specification No. CB-CL/CU ,SOR 7-9-5 | Supplying & erecting crimping type copper lugs for cable 70 sq mm completeas per specification No. CB-CL/CU ,SOR 7-9-5 |
| 57 | Supplying & erecting crimping type copper lugs for cable 95 sq mm complete as per specification No. CB-CL/CU ,SOR 7-9-6 | Supplying & erecting crimping type copper lugs for cable 95 sq mm complete as per specification No. CB-CL/CU ,SOR 7-9-6 |
| 58 | Supplying & erecting single compression type brass cable glands for 3½ core 120 sq mm cable as per specification No. CB-GL ,SOR 7-7-8 | Supplying & erecting single compression type brass cable glands for 3½ core 120 sq mm cable as per specification No. CB-GL ,SOR 7-7-8 |
| 59 | Supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm cable as per specification No. CB-GL ,SOR 7-7-6 | Supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm cable as per specification No. CB-GL ,SOR 7-7-6 |
| 60 | Supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm cable as per specification No. CB-GL ,SOR 7-7-7 | Supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm cable as per specification No. CB-GL ,SOR 7-7-7 |
| 61 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E)XLPE HT cable 3 x up to 70 sq. mm. with necessary material as per specification No. CB-JT/HT ,SOR 7-5-5 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E)XLPE HT cable 3 x up to 70 sq. mm. with necessary material as per specification No. CB-JT/HT ,SOR 7-5-5 |
| 62 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E)XLPE HT cable 3 x up to 50 sq. mm. with necessary material as per specification No. CB-JT/HT ,SOR 7-5-5 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E)XLPE HT cable 3 x up to 50 sq. mm. with necessary material as per specification No. CB-JT/HT ,SOR 7-5-5 |
| 63 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 400A, 8 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no. SW-MCCBPB. (Excluding MCCBs) ,SOR 5-7-9 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 400A, 8 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no. SW-MCCBPB. (Excluding MCCBs) ,SOR 5-7-9 |
| 64 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 400 A, 6 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no. SW-MCCBPB. (Excluding MCCBs) ,SOR 5-7-8 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 400 A, 6 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no. SW-MCCBPB. (Excluding MCCBs) ,SOR 5-7-8 |
| 65 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 250A, 12 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no. SW-MCCBPB. (Excluding MCCBs) ,SOR 5-7-5 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 250A, 12 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no. SW-MCCBPB. (Excluding MCCBs) ,SOR 5-7-5 |
| 66 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E)XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT ,SOR 7-5-5 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E)XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT ,SOR 7-5-5 |
| 67 | Providing & erecting 4 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-7 | Providing & erecting 4 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-7 |
| 68 | Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-6 | Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-6 |
| 69 | Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-4 | Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-4 |
| 70 | Providing & erecting 4 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line load bias in provided enclosure/panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-2 | Providing & erecting 4 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line load bias in provided enclosure/panel as per specification no. SW-MCCB (As per note\\" For use of 4 pole MCCB add 20% in rate) ,SOR 5-5-2 |
| 71 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. ,SOR 6-5-7 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. ,SOR 6-5-7 |
| 72 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. ,SOR 6-5-8 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. ,SOR 6-5-8 |
| 73 | Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. ,SOR 6-7-2 | Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. ,SOR 6-7-2 |
| 74 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs. ,SOR 6-7-1 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs. ,SOR 6-7-1 |
| 75 | Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, 200A ,SOR 5-10-35 | Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, 200A ,SOR 5-10-35 |
| 76 | Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, 250A ,SOR 5-10-35 | Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, 250A ,SOR 5-10-35 |
| 77 | Supplying and erecting DIN Type HRC Fuse cartridge 500V, 250A ,SOR 5-10-30 | Supplying and erecting DIN Type HRC Fuse cartridge 500V, 250A ,SOR 5-10-30 |
| 78 | Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, 300A ,SOR 5-10-36 | Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, 300A ,SOR 5-10-36 |
| 79 | Supplying and erecting DIN Type HRC Fuse cartridge 500V, 315A ,SOR 5-10-31 | Supplying and erecting DIN Type HRC Fuse cartridge 500V, 315A ,SOR 5-10-31 |
| 80 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. ,SOR 6-7-5 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. ,SOR 6-7-5 |
| 81 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete. ,SOR 5-7-15 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete. ,SOR 5-7-15 |
| 82 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete. ,SOR 5-7-16 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete. ,SOR 5-7-16 |
| 83 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification No. CB-JT/LT ,SOR 7-4-3 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification No. CB-JT/LT ,SOR 7-4-3 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender