Tender For Supply, Delivery And Installation Of 20 Kva Servo Motor Operated Copper Wound Line Voltage Stabilizer At Ph-3, Zone-Ii Of Gosaba (Rajapur) Water Supply Scheme Under Gosaba Block Under Smd, Phe Dte.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Aug 2026
0 days left
EMD
6800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Delivery And Installation Of 20 Kva Servo Motor Operated Copper Wound Line Voltage Stabilizer At Ph-3, Zone-Ii Of Gosaba (Rajapur) Water Supply Scheme Under Gosaba Block Under Smd, Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Charges for dismentaling the foundation of existing damaged voltage stabiliser after disconnection of power supply as per direction of EIC |
| 2 | Supply and delivery at site of 20 KVA 3 phase, Oil cooled type servo motor operated copper wound line voltage corrector conforming to IS-9815 (Pt-)- 1994 suitable for unbalanced input voltage with following specification including first filling of oil as per IS-335 where applicable. [Make: Approved make of P.H.E. Dte.] [Rate is inclusive of Riverrine Charge @ 5%] |
| 3 | a) Input voltage:- 3 phase main supply may or may not be balanced with respect phase to phase 200V-500V phase to neutral 115V-289V b) Output voltage: 3 phase balanced output voltage. Phase to Phase 400V 0r 415V ± 1% Phase to Neutral 230V or 240V ± 1% [provision should be made to adjust the variation of output voltage per phase by a variable pot well within ± 5% of output] c) Line Regulation: Output voltage should remain well within ± 1% of set voltage [from min to max i.e. either 400V or 415V supply variation] d) Load Regulation: Output voltage should remain neutral well ± 1% of set voltage be (from no load to full load] i.e. either 400V or 415V supply variation) e) Correction speed: Better than 35 Volts second f) Efficiency: Better than 95% on full load g) Cut off limit for [minimum & maximum] by limit switch with audio & visual. h) Metering indication: By selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available. |
| 4 | i) Lamp indication: For input and output should be provided [ 3 lamp per side] j) MCCB protection: For input side. k) Load protection: HRC fuse on each output phase should be available. l) Output over shoot: Beyond 210V to 255 volt/phase in case of \\"MANUAL MODE\\" and voltage protection \\"AUTO MODE\\" operation. m) VISUAL indication for under voltage over voltage of output. n) Manual mode: Up & Down correction with O/P voltage over shoot protection beyond 210V-255Volts per phase o) Nature of cooling: Oil cooled system p) Electric current over load protection q) Circuit for delay outputr) Input high voltage cut off above 470 volt s) Mode of Operation: AUTO/ MANUAL with a provision to restore the normal working of the unit \\" STANDBY OPERATION\\" should be available in case of any Electronic failure in auto mode t) Auto Mode: Normal / Standby. (Manufacturing test certificate should be provided at the time of delivery). |
| 5 | Supply and delivery of following materials: |
| 6 | 63 Amps 4 pole on load change over switch [Make: Approved make of P.H.E. Dte.] |
| 7 | 63 Amps Rewirable type TPN main switch [Make: Approved make of P.H.E. Dte.] |
| 8 | 63 Amps 4 way Copper busbar chamber box by 16 SWG Sheet steel enclosure including poecelain chair etc. with painting complete as per direction of the EIC [Make: Approved make of P.H.E. Dte.] |
| 9 | 25 sq. mm. 3.5 core 1.1 KV grade XLPE insulated Al. Ar. Cable as per IS:7098 (Part-II) 1988 with latest amendments [Make: Approved make of P.H.E. Dte.] |
| 10 | Making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by (4:1) cement mortar including down foundation bolts (if required) and plaster with neat cement finish as per direction of EIC. |
| 11 | Fitting fixing and connection of above supplied changeover switch, busbar and main switch as in item No. 2.01 to 2.03 on the wall by supplying all necessary materilas to complete the job. |
| 12 | Installation of the above voltage stabilizer of item No. 1 on the foundation including connection complete as per direction of EIC. |
| 13 | Drawing and connection of cable on wall as in item No.2.04 and all connection complete with all equipments as per requirement and as per direction. |
| 14 | Making joints of the cable by supplying compression type gland thimple, socket etc. as per requirement and as per direction. |
| 15 | Earthing Arrangement- |
| 16 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: |
| 17 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 18 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode. |
| 19 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 20 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. Length of Busbar is 0.5 Mtr. |
| 21 | Add GST @ 18% |
| 22 | Add Cess @ 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender