Housing Urban and Rular Development Government Departments Closing in 16 days TDR #56853635

Tender For Electrical Repair, Replacement Of Fittings, Installation Of 4 Nos Street Lights, Timer Repair/Replacement And Lightning/Surge Protection At G+3 Storied Hostel Building Of Promotees Training School, Jagatberh, Purba Bardhaman.

Issued by Government Departments · Purba Bardhaman, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Aug 2026
16 days left
EMD
34000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Purba Bardhaman → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Repair, Replacement Of Fittings, Installation Of 4 Nos Street Lights, Timer Repair/Replacement And Lightning/Surge Protection At G+3 Storied Hostel Building Of Promotees Training School, Jagatberh, Purba Bardhaman.

BOQ

Name of Work:- Electrical Repair, Replacement of Fittings, Installation of 4 nos Street Lights, Timer Repair/Replacement and Lightning/Surge Protection at G+3 Storied Hostel Building of Promotees Training School, Jagatberh, Purba Bardhaman.
Sl. No. Item Description
1Dismantling the existing wiring ,switch boards ,BDB,PBDB, light fittings and fixtures by Co's own tools, tackles & man power and mending good the damages & deposit the same to the Authority as per direction of EIC Office premises .
2Supplying and fixing 415V, 63 A TPN SFU with sheet steel enclosure front handel operated on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos.63 A DIN type HRC fuse .(L&T / Havells / Siemens ) (D-3/4a)
3Supplying and fixing double door 4 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with 80 MCB Isolator & 1 nos 32 A TP MCB , 2 nos 40 A and 3 nos (6-32A) MCB (upto 160A) [D-11/15] Make: LEGRAND, ABB - Itus, SIEMENS
4Supplying and fixing (4way) double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with 40A FP Isolator as incomer & 12 nos 6-32 SPMCB’s (C series) as outgoing. (Make : ABB ITUS / Schneider / Siemens) [D- 10 / 14]
5Supplying and fixing (6way) double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with 40A FP Isolator as incomer & 18 nos 6-32 SPMCB’s (C series) as outgoing. (Make : ABB ITUS / Schneider / Siemens) [D- 10 / 14]
6Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachmen. ( 6 way HTPN/ 4 way HTPN)(D-12/16)
7S & F 240V, 2 + 12 way, 6-32A per way SPN MCB BDB with SS encloser double-door with 40A DP Isolator as incomer & 12 nos 6-32A SPMCB’s (C series) as outgoing, concealed in wall & necy. inter connection of suitable size of copper wire with earthing attachment & neutral link ((Make : ABB ITUS / Schneider / Siemens)) ( D-9 / 13, D-5/6, D-6/7)
8Supply & Drawing 1.1KV Gr. 4 core 25 sq.mm. PVC/Al/Ar cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (Polycab / Gloster / Havell's / RR Kabel)
9Supply & Drawing 1.1KV Gr.2 core 10 sq.mm. PVC/Al/Ar cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (Polycab / Gloster / Havell's / RR Kabel)
10S/F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry & S/F socketing with finishing the end of XLPE/PVC armoured cables as below :-(F-4/7.a & F-5/8b)a) for 4 core 25 sqmm
11S/F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry & S/F socketing with finishing the end of XLPE/PVC armoured cables as below :-(F-4/7.a & F-5/8b)a) for 2 core 10 sqmm
12Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per metre, includingfilling the space between the brick & cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed (F2/1a)
13Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages andpainting. (F-1/2b)
14Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Mk. Havell's / KEI / Polycab / RR Kabel) in 19 mm dia 3 mm thick polythene pipe embeded in wall with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (all Mk. Anchor Roma / Legrand Myrius / Cabtree / Schneider) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish )PVC rigid conduit on ceiling portion and remaining portion is concealed.l (Avg Run 8 mtr).(E-25/4 )
15(Avg Run 10 mtr).(E-25/4
16Do do On Board(E-20/3i)
17Supply & Fixing 240 V, 2 nos 6 A, 3 pin Modular type plug socket (all Mk. Anchor Roma / Legrand Myrius / Cabtree / Schneider) with 2nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. inter connections (incl.socketing) with PVC Cu wire and earth continuity wire etc. [E-17 /1b + E-17 /4a, + E-17 /3a)
18Supply & Fixing 240 V, 1 no. 16 A, 1 no. 6A, 3 pin Modular type plug socket (all Mk. Anchor Roma / Legrand Myrius / Cabtree / Schneider) with 16A & 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. inter connections (incl.socketing) with PVC Cu wire and earth continuity wire etc. [E-17/1b, 3(a & b) & 4(a&b)]
19Supply & Fixing 240 V, 3 nos. 6 A 3 pin, 1 no 16 A 5 pin Modular type plug socket with 3 nos. 6A and one no 16 A Modular type switch (all Mk. Anchor Roma / Legrand Myrius / Cabtree / Schneider), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. inter connections (incl.socketing) with PVC Cu wire and earth continuity wire incl. socketing etc. etc.(Computer point) [E-17 /1f, E-17 /4, & E-17 /3] .
20Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (all Mk. Anchor Roma / Legrand Myrius / Crabtree / Schneider) without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (AC point) [E-17/5a]
21Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(AC Starter) As per GS. [E-19 /17 ]
22Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Mk. Havell's / KEI / Polycab / RR Kabel) of the following sizes in prelaid polythene pipe / PVC rigid pipe making necy. connection as required.(E-9/1)2x 1.5 sq mm+ 1X1.5 sq mm . (For 6 Amp Plug point)
232x 2.5 sq mm+ 1X1.5sq.(Power plug & computer)
242x 4 sq mm+ 1X2.5 sq mm.( for AC Point)
252x 6 sq mm+ 1X4 sq mm.(HTPN to SPN)
264 x 84/0.3 (6 sqmm) + 2x 4 sq mm( VTPN to starter)
274 x 80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC (Main Swich To 4way TPN) [E-9/1b1]
284x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC(Main Swich To 6way TPN) [E-9/1b1]
294x(25 sqmm) + 2x (16 sqmm) as ECC(Main Swich To VPN)
30Supplying and fixing PVC rigid conduit [Precision Make Medium] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E-16/7)a. 20 mm dia
31b.25 mm dia
32Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works.a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire (E-2/b 3 a)
33b.25 mm dia
34Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes (F-5/9)2x 1.5 sq mm+ 1X1.5sq mm
352x 2.5 sq mm+ 1X1.5sq mm
362x 4 sq mm+ 1X2.5sq mm
372x 6 sq mm+ 1X4 sq mm
384x 6 sq mm + 2 x 4 sq mm
394x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC. (F-5/9)
404x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
414x(25 sqmm) + 2x (16 sqmm) as ECC
42Supply and delivery of Single LED Fitting (Roboust Industrial Type suitable for surface, wall & conduit mounting, 22SWG Powder Coated, Screwed Down Cover) with all accessories((Mk, Philips, Fitting Cat No. TMC 502P 1xT-LED 22W P3242/ eqv. CGL / Jaquar )
43Supply and delivery of Twin LED Fitting (Roboust Industrial Type suitable for surface, wall & conduit mounting, 22SWG Powder Coated, Screwed Down Cover) with all accessories((Mk, Philips, Fitting Cat No. TMC 502P 2xT-LED 22W P3242/ eqv. Crompton / Jaquar / Osram )
44Supply& Delivery 18/20LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz,Operating temp range 0o to 40o C, internal surge protection of 2.5KV(internal) with Short & Open circuit protection , THD < 10% , P.F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Lifeprojection shall be calculated as per TM-21 methodology), CCT5700°K /6500°K, and Fixture shall be of relevant BIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ NameEngraved/ Embossing/ Screen printing on housing, with Minimum 5year OEM warranty. All test report except L80 should be from 3rdparty NABL accredited Lab as per BIS shall be submitted.(System lumen efficacy ≥115 lm/Watt)(Mk, Philips, Fitting Cat No. Mas LEDTube 1200mm 18W 865 T8 I – 2100lm/ eqv. Crompton / Jaquar / Osram )
45Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required as per direction of EIC( C-2/14C)
46Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [Ref : C-2/17]
47Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)(D-14/29)
48Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copperwinding, steel/Al body. Power Factor not less than 0.9 and minimum airdelivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Make :Crompton Aura Prime/Orient Quaser/Khaitan] (2 years warranty certificate should be provided )
49Supply & delivery of 230 V, 50 Hz, single phase, 38 watts, 36\\" (900 mm)Sweep, speed 400 rpm (minimum), A.C. Ceiling Fan and class ofinsulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copperwinding, steel/Al body. Power Factor not less than 0.9 and minimum airdelivery 140 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required..[Make :Crompton Aura Prime/Orient Quaser/Khaitan] ( 2 years warranty certificate Should be provided )
50Fixing ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. (C-3/21A)
51Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop(C-3/24a)
52Extra for additional one letter including hifen, stroke or stop(C-3/24b)
53Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (all Mk. Anchor Roma / Legrand Myrius / Cabtree / Schneider) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. as per GS.(E-18/10)
54Supply & Fixing of 220 -240V, 85-90 W, 3/4 blade, 1300 -1425 rpm, 450mm (16\\") dia metal body & blade Wall Bracket fan inbuild thermal overload protection with auto reset. (Make - EPC or eqv. Crompton / Orient - Torendo Wall II)(2 years warranty certificate Should be provided )
55Fixing only 300mm (12\\") exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust (C-14/28)
56Supply & delivery of 230 V, 50 Hz, single phase, 48 watts, 12\\" (300 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class ofinsulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding,steel/Al body. Power Factor not less than 0.9 and minimum air delivery1145 cmh (minimum) capacitor with safety pin, nut bolts, washers,temperature rise=75 degree C (max.), insulation resistance more than 2mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor singlecore cable and earthing etc. as required. (3 years warranty). [Make:- Crompton/ EPC/ Orient](2 years warranty certificate Should be provided )
57Supply and fixing net guard Exhust fan hole made with 1'(one) inch square 14/16 swg M.S net , round shaped frame by 20 x 5 m thick MS Plate and Rain water protection shade made by 14 SWG semi circular shape the total frame fixed with the wall by means of suitable size fastener bullet & nuts, bolts incl painting etc.a) 12 \\"\\" dia
58Supply & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board(D-13/20a)
59S& F B 22 batten holder (Make Philips/Havells) (For Kitchen, Bathrooms , Varandha and Corridor) for Qtr portion
60S&F of 12W B22 LED Lamp on exising batten holder (Make Philips/ Crompton/Havells) (For Kitchen, Bathrooms , Varandha and Corridor) for Qtr portion .
61Compound Light Supply & Delivery of 70/60Watt LED Street light fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT (Crompton, LSTS-30-CDL-M/Philips, BRP 032 LED60 CW/WW SLR GR PSU)on pipe bracket
62Fixing only outdoor/street light type fluorescent light fitting or MV/LED light firing complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. Gi reducer as required. S&F 40 mm CE pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy, length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and maling connections as required and mending good damages towall inct, painting etc.
63Fixing outdoor type fluorescent/SV/MV light fitting on poleincluding S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium)bracket with 40 mmx10 mm thick, MS clamp etc. and providingwiring with 2x1/1.40 PVC insulated and sheathed wire (singlecore) from loop box at the base of pole to light fiting through pole& bracket (without control switch) including making connections &painting. (H-5/4)
64Supply and delivery of 90LED Street light fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and ecessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(TRP-411-90-57-SL-GL-NSG) fficacy>110LPW, 10KV SPD included - N.S.
65Supply and Fixing of 40 W LED Post Top light fittings ,Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source on existing GI pole incl. necy. connection.( Make: Philips/ Wipro / Jaquar - LGTP06X040XN/ Panasonic - PPTM03408/ Havells - RUBYPT40WLED757PSYMTOPC)
66Supplying, installation, Testing & Commissioning of Flood light 100Watt LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. ( Crompton TFS 504-100-57-NL-SL GL NSG / similar make of Philips BVP 282 LED 120 CW FG Sy5 WB100WV1/ Wipro)
67Supplying & Fixing Gl waterproof type looping cable box size 200x150x100 mm deep having 4 min thick comprising of one 250 VIS A lat-kat fase unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2. core 16 sqmm uble and having lined with gaskettel Gl top cover with forass machine screws etc, earthing terminal with lug on sweet cultular pole near hase, including S&F 40x6 min thick. MS clamps with belts, nuts etc. including painting with anticorrosive paint.
68Supply and drawingdesigned for 1.1 kV Stranded copperconductor 3 X 1.5 sqmm PVC insulated FRLS wire flexible in 13 mm dia polythene pipe embedded wall from loop box to light fittings incl. connection.
69S&F Street light/Outdoor light/Compound Light Timer Box with 16 SWG sheet metal enclouser (Water Proof) concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions of EIC i) 250 V, DP 32A MCB, C Curve - 1 No. ii) 250V, 3P Power Contractor 32A (1NO+1NC) with accessories - 1 Noiii) Dial Type Analog / Digital Time Switch - 1 No.iv) Toggle switch for manual / auto operation - 1 No. v) 10 A capacity output MCB - 3 Nosvi) Necessary connection by copper wire. [ Accessories Make : ABB, Simens, Legrand, L&T]
70SITC of 2 Nos. Glow Sign Board : Supply & Installation of 6\\" (152mm) depth box type MS Structure size i) 10ft. X 4 ft (40sqft) (40X2=80sqft) duly fabricated & welded by 40 mm x 40 mm / required size M.S. square holow bar 3 mm thick (ISI mark), frame with back & other sides covered by 22 SWG Al sheet & edge covered by Al angle frame. Frame to be fixed with necy. nos. nuts, bolts, washers, supporting angle iron clamp etc. and ACP sheet on all sides to be moulded uniformly of the board & MS structure to be provided including painting (2 coats of RO primer & 1 coat Al paint over it) etc. MS Structure to be made such a manner that front side can be opened towards up direction for taking maintenance. S&F 3 mm thick \\"Blue\\" Colour ACP sheet on front side of MS structure. Supply and fixing of LED Module inside the acrylic letters.The specification of the LED Module is given below :A) LED : White - necessary module wattage, double / triple line to be fixed inside the Acrilyc letters on ACP board (Mk. : Samsung Korea / ISI Approved) B) Type : Double line fixed C) Life: - 100000 burning hours, D) Intensity : Same & smooth throughtout, no brighter or light or dark patches. E) Visibility: 150 mtr. for normal eye. F) Power supply : Required AMP (meanwell LRS-<...>-12)G) Ambient Air : 0-50C.100% relative humidity.H) Power Consumption : 1.08 watt per module.Suitable copper wire laying through PVC rigid or flexible pipe & terminal connection as per direction of the EIC. Supply & Fixing of special type imported acrylic letter required height fixed on ACP sheet. The letter font (English & Bengali, Bold)Letter colour = White.Encrypted with : \\"……..........................................................\\"NB. AS PER REQUIREMENT & APPROVAL FROM AUTHORITY END color may also be varied.S & F water proof 750 watt power supply system IP65, 50/60Hz frequency, 108 to 305 V AC powersupply, >.095 power factor for LED lamp. (Make : Meanwell / Groen / Impex)
71Installation the above sign board on the main entrance gate by 2 Nos M S Joist of size 150 mm X 75 mm X 5 mm thickness ( I - Section) of 25 ft long. The sign board is fixed on 50mm X 50 mm X 6 mm thick M S angle structure rectangle shaped (22 ft X 4 ft) with proper brcing by 40mm X 40mm X 6 mm thick M S angle ( 4 Nos ) proper welding. The sign board resting on the M S C - channel of size 75 mm X 50 mm X 6 mm thick 22 feet long ( 1 No) for resting the glow sign board in hanging portion below the glow sign board bottom protion between two pillars by welding method.
72Earthing :- Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe. [ 2(a)/G-1 ]
73Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Soft Soil [1(a)/G-1 ]
74Supplying & fixing medium gauge 40 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.(f-6/11d)
75Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.(G-2/4a)
76Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages 10 SWG
77LC Conductor:-S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long Gl pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) [J-1/1]
78S & F of 4 SWG GI (Hot Dip) wire on Parapet/ Roof/Plinth / Surface of wall for lightning conductor as required (for Horizontal runs) with 40 mm long G1 Staples spaced not exceeding 1300 mm part incl. mending good all the damages to the building works [J- 1/2]
79S & F of 4 SWG GI (Hot Dip) wire on wall for the lightning conductor as required (for vertical run) with Gl Staples (40 mm long) spaced not exceeding 1 Mtr. apart incl. mending good the damages to building works (excluding hire charges of scaffolding) -J-1/3]
80Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) Gl pipe protection as below and mending good damages to the building works:Length upto 0.5Mtr. [1-1/4a)
81Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint. [J- 1/5]
82Making soldered joints between conductors and down pipes/other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG Gl (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint [J-1/6]
83Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. [J-1/7]
84Supply & Fixing of Testing points by 20 mm x 3 mm thick Gl (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, Gl bolts, nuts, check-nuts, spring washers etc. required. [J-2/13]
85Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long Gl bolts, double nuts, double washers incL S & F 15 mm dia Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 1.65 Mts. below the ground level as below:ByISI-Medium Gl pipe (G-1:2a) (02no for Building El work and 10 no for LC work)
86Excavation of sod for installation of Earth Eletrode and filling & ramming For Soft Soil (G-1/a)
87Supplying & fixing earth busbar of galvanized (hot Dip) MS dat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the husbar complete with Gl bolts nuts, washers, spacing insulators etc. as required [G-2/4a](0.5 mtr 10nos)
88Air-conditioning Work:- Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cellelastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM ecommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min)
89Supply & Installation of Extra Add-on items- Supplying, Installation, testing and commissioning including vaccumiazation andNitrogen testing of sizes of soft/hard drawn copper refrigerant pipingHVAC grade 5/8\\"(for suction) & 1/4\\"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screw, insulation tape, fastner etc for above AC machine as per direction of EIC.( Maker for Cu pipe - Rajco,/ Royku,/Mandev,/ Nippon & Make of Nitrile Rubber insulation - m Aeroflex/ K -flex /Accrofle /Armacell)
90Supply and laying 3 core 4 sq mm PVC unarmoured copper cable ( From Starter to AC outdoor Connection)( Make- Gloester/Havells/ Finolex/ polycabas approved by EIC)
91Supply and laying 4 core 2.5 sq mm PVC unarmoured copper cable ( From Starter to AC outdoor Connection)( Make- Gloester/Havells/ Finolex/ polycabas approved by EIC)
92Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes (2.5 sqmm)
93(4 sqmm)
94Providing for Installation of the above said Split AC Indoor & outdoor unit by Fixing iron angle frame/ table on wall/ roof top & mending good the damages as per directio of EIC.
95S & F of 5/8inch or 20mm dia PVC breaded flexible drain pipe without insulation.
96Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator & necy. Connections.(Make:-Anchor Roma/Legrand Myrus / Cabtree) . Please Enable Macros to View BoQ information
97Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator & necy. Connections.(Make:-Anchor Roma/Legrand Myrus / Cabtree) . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56853635
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Repair, Replacement Of Fittings, Installation Of 4 Nos Street Lights, Timer Repair/Replacement And Lightning/Surge Protection At G+3 Storied Hostel Building Of Promotees Training School, Jagatberh, Purba Bardhaman.
Basic Detail
Tender No WBPWD/EEBED/NIQ-58/2026-27
Bidding Type Tender
Location
City Purba Bardhaman
State West Bengal
Key Dates
Publish Date 05 Aug 2026
Submission Date 21 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 34000
Exemption Not Available
Document List
2ac3786b-c3b0-40de-9fb9-5041012e1aad.html
BOQ_5088545.xls
Tendernotice_1 (16).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

2ac3786b-c3b0-40de-9fb9-5041012e1aad.html

xls

BOQ_5088545.xls

pdf

Tendernotice_1 (16).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders