Tender For Estimate For Repair And Maintenance Of Various Buildings Under Jurisdiction Of Patialacanal Circle At Wrd Patiala Complex
Tender Value
33.49 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
8 days left
EMD
67000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Estimate For Repair And Maintenance Of Various Buildings Under Jurisdiction Of Patialacanal Circle At Wrd Patiala Complex
BOQ
| Sl. No. | Item Description |
| 1 | Scrapping Whitewash and colour wash |
| 2 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete\\" |
| 3 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade\\" |
| 4 | Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade\\" |
| 5 | Vitrified floor tiles in light colour shades made using double charged Technology (600 X 600mm)CSR 14.112 |
| 6 | Reinforced cement concrete M-25 For Solid slab super-structureincluding centering and shuttering\\" |
| 7 | Dismantling Concrete Reinforced cement concrete |
| 8 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.\\" |
| 9 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.\\" |
| 10 | Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect.\\" |
| 11 | roviding and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.\\" |
| 12 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 13 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level.\\" |
| 14 | Red meranti Normal (15 to 16 kg per cft. Approx.) doors shutter windows shutter including hinges, screw and cords etc.Complete fixed in position Panelled, glazed or glazed and panelled.\\" |
| 15 | Cement concrete 1:3:6 (mixing by mechanical means using concrete mixer volumetric type) |
| 16 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes forinlet, outlet and over flo pipes but without fittings and base support for tank.\\" |
| 17 | Supplying and fixing new wooden fillets wherever necessary Red Meranthi wood fillets 3.20mx0.0125mx0.0125m\\" |
| 18 | Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of IstClass and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. |
| 19 | Water proofing treatment of RCC structures (after making the surface clean, dry & free from all internal voids or honey combs ), with Zycosil /equivalent water proofing Solution (1 litre of Zycosil / equivalent & 20 litres of potable water stirred first & 2 litres of Zycoprime / equivalent added and stirred (total 23 litres)) using two coats till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. |
| 20 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval ofEngineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect.Size550 mm x 400 mm x 815 mm |
| 21 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth |
| 22 | 20mm thick grey polished skirting or dado consisting of bottom layer of 16mm thick cement sand plaster 1.3 and finished 3mm thick topping of neat cement rubbed and polished including rounding of junction with floors |
| 23 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm,100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shadecomplete. |
| 24 | Whitewashing two or more coats |
| 25 | Whitewashing( two or more coats) |
| 26 | Colorwashing two or more coats |
| 27 | Repairs to plaster in patches of Area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 Metres leadWith cement mortar 1:4 (1 cement: 4 sand) Taking area 2.5 sqm (Lumpsum qty) |
| 28 | Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer |
| 29 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 30 | Supply and Installation of Printer for Office use |
| 31 | Supply of desktop computer For office use complete in all respect |
| 32 | Providing Inverter with battery complete in all respects |
| 33 | supply and installation of 1.5 ton ac in xen room |
| 34 | Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. Boring with 150mm id Housing Pipe |
| 35 | Supplying, assembling, lowering and fixing in vertical position in bore well, un- plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in-charge. 100 mm nominal size dia. |
| 36 | Supplying, assembling, lowering and fixing in vertical position in bore well un- plasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in- charge. 100 mm nominal size dia |
| 37 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.100mm internal diameter |
| 38 | Providing and installing submersible motor 1.5 HP alongwith assembly and electrical connections complete in all respects. |
| 39 | excavation in foundation trenches |
| 40 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure |
| 41 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 42 | 12.5 mm thick cement plaster 1:5 |
| 43 | 12.5 mm thick cement plaster 1:4. |
| 44 | Earth filling under floors with surplus soil containing more than 40% gravel or kankar excavated from foundation & taken only from outside the building plinth in 15 cm layers including ramming watering and consolidation lead upto 30 metres |
| 45 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 46 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make ( to the approval of Engineer-in-charge)consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect. Size 550 mm x 400 mm x 815 mm |
| 47 | Providing and fixing vitreous chinaware standard pedestal of approved make ( to the approval ofEngineer-in-charge)for wash basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin. |
| 48 | Extra for providing and fixing PVC 32mm waste pipe |
| 49 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval ofEngineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 50 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 51 | Providing and laying, jointing fixing and testing G.I. Pipe lines B-Class including cost of specials such astees, bends,sockets, elbows etc. esting, cutting, threading Inside building complete. |
| 52 | Providing and laying, jointing fixing and testing G.I. Pipe lines B-Class including cost of specials such astees, bends,sockets, elbows etc. esting, cutting, threading Inside building complete. |
| 53 | 20mm i/d |
| 54 | 25mm i/d |
| 55 | Providing, fixing and jointing Union Couplings in G.I. Pipe lines.15mm i/d G.I. Union |
| 56 | 20mm i/d G.I. Union |
| 57 | 20mm i/d G.I. Union |
| 58 | 25mm i/d G.I. Union |
| 59 | Provo/ding, fixing and jointing gun-metal peet valves (Heavy Pattern) with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 60 | Cutting holes upto 23cm square for pipes in flooring and roofs of bricks, tiles with lime concrete or cement concrete and making good including repointing, replastering and colour or white washing where required |
| 61 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. |
| 62 | Providing and fixing in position automatic brass ball valves in tanks |
| 63 | Construciton of Brick masonary Plat form for over head water tanks mansory wall. |
| 64 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes to I.S.I. 13592 of approved make (to the approval of EIC) including cutting, jointing, wastage, but excluding cost of lead jointing |
| 65 | 90mm i/d SWR UPVC pipe lines laid complete |
| 66 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes to I.S.I specifications of E.L.C manufacture or any other reputed firm including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 67 | Vent Cowls |
| 68 | Coupler |
| 69 | P Trap/Floor Trap 110mm x 75mm |
| 70 | Providing & Fixing in postion 15 mm i/d bib cock of best quality (as approved by the Engineer-in-charge). |
| 71 | Providing & Fixing in postion stop cock / Angle valve (as approved by the Engineer- incharge). |
| 72 | Providing and fixing in PVC flexible tube connection of approved make complete in all respects |
| 73 | Providing & Fixing in position C.P. Brass extension piece 15mm dia, 15mm long or 25mm long or 50mm long with various fixtures complete in all respects (as required by the Engineer-in- Charge) |
| 74 | Providing and fixing in position GI tank nipple of approved make (to the aapproval of EIC) in PVC wtater storage tanks complete in all respects |
| 75 | Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete |
| 76 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, Cillral mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items) |
| 77 | Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect |
| 78 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm Thick |
| 79 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc |
| 80 | 12.5mm thick cement plaster 1:5 |
| 81 | 12.5 mm thick cement plaster 1:4 |
| 82 | Single Tee With Door |
| 83 | Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 84 | Earth work in excavation in Foundations Trenches etc., for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, Pump h uses, sumps, screening chambers and other similar works to full dimension and depth as shown on the drawings or as shall be required by Engineerin-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around Plinth/structures in 15 cms. layers with compaction including Disposal of surplus spoils as Directed within a lead of 30 Metres |
| 85 | Cement Concrete 1:4:8 withstone aggregate of size. 40mm guage |
| 86 | Cement Concrete 1:2:4 with stone ballast of size. 40mm guage |
| 87 | Shuttering for faces of concrete foundations and foundations beam and plint beam (vertical or battering) |
| 88 | 12.5 mm thick cement plaster 1:2 |
| 89 | Cement rendering on plaster 1mm thick |
| 90 | Providing and fixing RCC manhole covers only R.C.C. Manhole cover \\"560mm i/d RCC man hole cover only as per ISI Medium duty\\" |
| 91 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 92 | Providing and fixing in position H.C.I. soil waste vent or antisyphonage pipes to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer-in-charge ) including cutting, jointing, wastage, but excluding cost of lead jointing. |
| 93 | Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer-in-charge ) including cost of lead yarn, fuel and tools etc. |
| 94 | Providing and fixing in position H.C.I specials for soil waste vent or anti syphonage pipes to I.S.I specifications (IS:1729) of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 95 | Provision for HCI specials for making inlet or outlet HCI connections inside the septic tank such as tees bends, etc. complete in all respects. |
| 96 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½\\"\\" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- |
| 97 | Wiring light point |
| 98 | Wiring 6Amp. Plug control comprising wall socket point |
| 99 | Wiring 16/20Amp. power plug control point |
| 100 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: \\" Supply and erection of switches, sockets and other accessories (flush piano type/modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- 6/10amp. One Way Modular Switch (One Module) |
| 101 | 16/20amp. One Way Modular Switch with Indicator (One Module) |
| 102 | 6amp. 2/3 Universal Modular Shuttered Socket (two Module) |
| 103 | 16/20amp. Universal Modular Shuttered Socket (two Module) |
| 104 | Step type Modular Electronic Fan Regulator 100watts (One Module) Step type Modular Electronic Fan Regulator 100watts (One Module) |
| 105 | Bakelite Batten Holder (Large size) |
| 106 | Supply and erection of Modular Cover Frame (Complete set) on the existing metal box including fixing and connection of existing switches and sockets and other petty material etc: -Modular Cover Frame One or Two Module |
| 107 | Modular Cover Frame Six Module |
| 108 | Modular Cover Frame Eight Module |
| 109 | MINIATURE CIRCUIT BREAKERS: \\" Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 110 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 111 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 112 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- \\"Heavy Gauge PVC Conduit Pipe 20mm dia. (On Surface) |
| 113 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: \\"Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-\\" |
| 114 | Overall size 1.5sq.mm (Un-sheathed) |
| 115 | Overall size 1.5sq.mm (Un-sheathed) |
| 116 | DISMANTLING WIRING POINTS & FITTINGS: Dismantling old wiring points including necessary repairs to wall etc:-\\"Fan, light or call bell point |
| 117 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimblewithsuitable size steel bolt,washers& doublenut)with30cmx 60cmx2mmthickcopper plate (made cylindrical) burriedbelowgroundlevel in theholeof excavationhavingboredia 125mm and surrounded by salt & charcoaldustmixture(20kg.) ncludingfixingthecopperwireru nthrough20mm dia.G.I. pipe (A-Class) recessed inwall andinflooretc.,uptosuitableLengthinmetre (includingboreLength).G.I. pipe 20mmdia. (A-class) of suitableLength shouldbelaidintheholeofexcava tion1 feet belowground level andhavingGI Reducer 50mmx 20mmwithPVCCap Forpouringwater) fixedonthetoplevelof thepipe. 300mmx300mmx300mm deephaudiofFirstclassbricksfini shed with 1:4 cement plaster and haudi coveredwith cast iron lidhaving size 300mm x 300mm (Heavy) around the hole of excavation\\" |
| 118 | \\"Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casingpipe after the tube well is lowered & tested , equipment as requriedsuchashandboring machineand itsaccessory, transportation to site and vice versa etc. complete in all respect.\\" Boring with 150mm id Housing PipeBoring with 150mm id Housing Pipe |
| 119 | \\"Supplying, lowering of MS Pipe as per IS:4270-2001 includingMS sockets having dimensionsasper IScodedulyweldedwith MSelectrodetohaveextrastreng thtolower the pipe into tubewell bore. 100mmnominal diameter (weight 14.5kg per metre) 5.40 mm thickness\\" |
| 120 | Providing and fixing in position singel socket SWR UPVC soilwasteor anti syphonage pipes asper IS13592ofE.D.Cmanufactureorofany other reputed firm including cutting, jointing wastage, but excluding cost of jointing.75mmo/dsinglesocketSWRUPV Cpipe lines laid complete\\" |
| 121 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe withG.I. specials as per ISI-4985, includingcost ofG.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 10 Kgf/ 20mm i/d \\" |
| 122 | Providing Air cooler complete in all respects |
| 123 | Providing Lawn mower complete in all respects |
| 124 | Providing Ceiling Fan complete in all respects |
| 125 | Providing LED Tube complete in all respects |
| 126 | Providing Office type steel almirah complete in all respects |
| 127 | Providing Office type chair complete in all respects Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender