Tender For special Repair To Plinth Of Dvor Antenna At Afa And special Rep / Rep Of Existing Old Soun Proof Glass Of Atc Tower (Qty-25) At Afa
Tender Value
24.60 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
12 days left
EMD
49200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Medchal Malkajgiri → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Plinth Of Dvor Antenna At Afa And special Rep / Rep Of Existing Old Soun Proof Glass Of Atc Tower (Qty-25) At Afa
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of Plain cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone agg) 100mm thick as in floor sub base etc as specified directed. |
| 3 | M&L for 100 mm thick PCC 1 : 2 : 4 type B-0 using 12.5 mm graded stone aggregate as in screed bed in floors all as specified and directed. |
| 4 | M&L for Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L 75mm thick plain cement concrete 1 : 3 : 6 mix type C2 (using 40mm graded stone aggregate) as in plinth protection laid in alternative bays and finished even and smooth with out using extra cement including necessary form work complete all asspecified and directed by Engr-in-Charge. |
| 6 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/Dense Soil complete all as specified and directed. |
| 7 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed.. |
| 8 | M&L for pre-cast cement concrete block masonry of Type C1 1:3:6 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4 etc complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L rendering 15 mm thick in cement plaster 1:4 on fair faces of PCC block masonry or concrete surfaces finished even and smooth without using extra cement all as specified and directed by Engr-in-Charge. |
| 10 | Extra forming fair finished drain or channel 60 cm/40cm inner girth in cement concrete using extra cement including forms, moulds, mi-tried/ stopped ends etc. complete all as specified and as directed. |
| 11 | M & L for cement concrete Type B0 1:2:4 (12.5 mm graded aggregate) as in copings as directed |
| 12 | S&F Aluminium dividing strips, 1.5mm thick,28mm width inserted in position, conform to design complete all asspecified and directed by Engr-in-Charge. |
| 13 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 14 | All as per item no 1 above but exceeding 1.50mtr but not exceeding 3mtr complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for Loose filling with aggregates of gauge not exc 40 mm to in soakage pits, soakage wells etc complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for loose filling with course sand in trenches / foundations including watering and consolidation complete all asspecified and directed by Engr-in-Charge. |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 18 | Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 19 | M&L Drilling 6'' (150mm) bore , holes by rotatary drilling method below GL in any type of soil incl disposal and surplus soil to outside md land complete all as specified by Engineer-in-charge |
| 20 | S&F Plastic PVC pipe of pressure rating 6kg / CM2 150mm dia, ISI mark in standard length, complete all as specified by the Engineer-in-charge |
| 21 | As per Item no 20 above but sloted pipe having 2.3mmX7.5mm slot complete with necessary fitting jointed complete all as specified by the Engineer-in-charge . |
| 22 | S&F PVC welcap 6'' (150mm ) bore mild steel ARW Pipe having internal threads and width welde iron handles and fixed in position complete all as specified by the Engineer-in-charge . |
| 23 | S & F Mild Steel works as in Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all asspecified and directed by Engr-in-Charge. |
| 24 | M&L for Preparation of new Stell and Iron surfaces Surfaces of any description, over 10cm in width or girth,not otherwise described and painting with two coats of Synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 25 | Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) with or without mullion duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of 62 mm x 58 mm x 2.40 mm for outer frames, 62 mm x 74 mm x 2.40 mm for mullion sections apable of mounting single glazing system structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm prefabricated & welded through fusion welding the door sash shall be fitted with 24 mm DGU glass of reputed make duly fixed with TPV Gaskets for sash & Glazing bead shall be coextruded with Grey colour soft PVC. System shall be provided with standard hardware, single point locking using cockspur handle and friction stays. The system is to be installed at the site using anchor fasteners, silicone rubber sealant, easy glazing/ deglazing at site, etc. NOTE: Rates include removing the old existing DGU glass frame and fixing the height at approximately 21.00m, necessary arrangements like lifting material by manual/mechanical means or scaffolding, etc. |
| 26 | S & F stainless steel (Grade 304) tubing of any diameter of circular, square or rectangular in shape of grade AISI-316 (type Austenitic anticorrosive in nature) as in railings / grills / designer work including post top cap, bottom plate, cutting, bending, seamless welding and fixing in any type of location incl taking down old railing of any description complete all as specified and as directed. |
| 27 | Providing & fixing 12mm thick micro tegular false ceiling abony in colour / ordinary colour approved by GE , at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRC0 .50 to 0.75 as per IS 8225 :1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1OOOmm length and L- shape level adjuster of size 85x25x2mm . Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. colour was ebony in colour / any other colour approved by GE .The work shall be carried out as per specifications , drawing and as per directions of the Engineer-in-Charge. |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises. |
| 29 | M & L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in Apoxy Grout 2 to 3 mm spacer and filled with white cement mixed with matching pigment over and including 20 mm thick screed bed in CM 1:6 all as specified. |
| 30 | Material and labour for Glazed ceramic coloured tiles in vertical surfaces 600X300X 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10mm thick backing coat on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed. |
| 31 | Taking down chowkats or frames with shutters exc 1.5 sqm but n.exc 4 sqm each (without taking off shutters from the frame) complete all as directed. |
| 32 | S&F 12mm Thick HDF Wooden laminated flooring AC-4 Type as per EN-13329 standard planks size should not be less then 1200X190mm including 0.2mm thick HDP Sheet and 2mm thick PU foam under lay sheet with click lock system in wooden planks complete all as specified and as directed . |
| 33 | S&F powder coated aluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 34 | S&F powder coating anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, 3 Nos hinges, locking system ,anodised aluminum snap beading screws etc. complete all as specified |
| 35 | S&F 250 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified. |
| 36 | S&F of 100mm Aluminum anodised barrel tower bolts of extruded section complete all as specified. |
| 37 | S&F 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor |
| 38 | S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty/ glazing clips in square n exc 0.5sq. m in each pane |
| 39 | S& F 12mm Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work |
| 40 | M & L for preparing old plastered or unplastered surfaces on walls including cornices applying a coat of alkali resistant priming paint followed by applying 2mm thick wall care putty and making the surfaces smooth and even with sand paper and finally applyingand applying two coats of exterior weather proof paint all as specified and directed by Engineer-in-Charge. |
| 41 | S & F in repair PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls / floor incl taking down old pipes of any description complete all as specified and as directed |
| 42 | M & L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge. |
| 43 | M&L for dismantling, servicing, repair and re-installation of existing 4.0 TR Cassette Type ceiling mounted Air Conditioner, including careful dismantling of indoor and outdoor units without damage to false ceiling or structure, recovery of refrigerant, disconnection of copper piping, drain piping, and electrical connections; thorough inspection, cleaning of coils, filters, blower and condenser using suitable chemicals; checking and servicing of compressor, fan motors and electrical components; rectification of faults including leakage repair, replacement of damaged copper pipes with insulation, drain pipes, cables and accessories as required; complete evacuation and charging of refrigerant gas as per manufacturer specifications; re-installation of units with proper alignment, re-laying of insulated copper piping, drain piping with proper slope, and electrical connections; sealing of openings, testing and commissioning including trial run, checking of cooling performance, airflow, noise, drainage and recording of parameters; all materials such as refrigerant gas, copper pipes, insulation, drain pipes, cables, fasteners and consumables to be included for complete and satisfactory operation of the system complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. |
| 44 | Description all as per Item Nos 43 above but for Split Type Air Conditioner of 1.5 Ton capacity. |
| 45 | S & F LED square shape (2' x 2') slim ceiling RECESS light fitting 40 W or next higher rating, CRI > 80, CT>5700 K (White), integrated type, with high efficiency electronic driver, surge suppressor / protection & high brightness LEDs, with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size incl taking down old unsv conventional light fittings & depositing to MES Storeyard complete all as specified & as directed by Engr-In-Charge. Cat No : LKM2240N of make Luker or techno-commercially equiv in Havells/Jaguar/Philips. Please Enable Macros to View BoQ information |
| 46 | S & F LED square shape (2' x 2') slim ceiling RECESS light fitting 40 W or next higher rating, CRI > 80, CT>5700 K (White), integrated type, with high efficiency electronic driver, surge suppressor / protection & high brightness LEDs, with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size incl taking down old unsv conventional light fittings & depositing to MES Storeyard complete all as specified & as directed by Engr-In-Charge. Cat No : LKM2240N of make Luker or techno-commercially equiv in Havells/Jaguar/Philips. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓