Tender For Repair/ Maintenance & Periodical Services Of Jcos Mess & Jco Club Of Bldg No Ar/Ccp/17 & Ar/Ccp/155 At Bn Hq Veng
Tender Value
2.59 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
12 days left
EMD
5200
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Churachandpur → Manipur
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance & Periodical Services Of Jcos Mess & Jco Club Of Bldg No Ar/Ccp/17 & Ar/Ccp/155 At Bn Hq Veng
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete of plinth protection Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation, levelling & dressing & finishing the top smooth. etc., complete. |
| 3 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) . |
| 4 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. and Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete as per manufacturer's specification, One or more coats on old work. |
| 5 | Finishing walls with water proofing cement paint of required shade : Old work (one or more coats @ 2.20 kg/10 sqm) complete. Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work. |
| 7 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group B |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 9 | Replacement, Supplying and fixing following modular 5/6 amps switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | Replacement, Supplying and fixing following modular 15/16 amps switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | Replacement, Supplying and fixing following modular 3 pin 5/6 amps Socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | Replacement, Supplying and fixing following modular 6 pin 15/16 amps Socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | Replacement, Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 14 | Replacement, Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 15 | Replacement of Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 16 | Supplying and fixing 6 way , Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 17 | Supplying and fixing 5 amps to 32 amps rating single pole, 240/415 volts, 10 KA \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | Supplying and fixing 5 amps to 32 amps rating SPN, 240/415 volts, 10 KA \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender