Tender For Supply Installation Testing and Commissioning of Ac Machines With Allied Electrical Installation Work In Various Rooms At Newly Constructed Building Of Diet, Hastings, Alipore, Kolkata-700027---Air Conditioning Work
Tender Overview
Project Description
Tender for Supply Installation Testing and Commissioning of Ac Machines With Allied Electrical Installation Work In Various Rooms At Newly Constructed Building Of Diet, Hastings, Alipore, Kolkata-700027---Air Conditioning Work
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. (Make:- O-General/Mitsubishi -Heavy/Mitsubishi Electric/Daikin) |
| 2 | Cooling Capacity- 6.6 kW (Minimum) , Minimum ISEER - 5.0, BEE level - 4-Star(min) |
| 3 | Cooling Capacity- 8.5 kW (Minimum) , Minimum ISEER - 4.0, BEE level - 4-Star(min) |
| 4 | Cooling Capacity- 9.8 kW (Minimum) , Minimum ISEER - 4.0, BEE level - 4-Star(min) |
| 5 | S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of above AC machines. |
| 6 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above said AC, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (Make- Approved by EIC) |
| 7 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 8 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 9 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 10 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines. |
| 11 | 2.5 sqmm, 3/4 core copper cable (FRLS type) (Make- Polycab/Gloster/Finolex/Havells /RR Kabel as Approved by EIC) |
| 12 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make- Supreme / Oriplast) |
| 13 | Supplying, fabrication & fixing of outside Iron Structure platform of suitable size by grouting MS u-channel of 6mm thick of size (75 mm x 40 mm x 4.8 mm) for making platform for installation of outdoor unit of split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6mm and supporting angle of 50 mm x 50 mm x 6mm in each platform. The platform should be baricated & safe for ODU Maintenance in outer edge for transmitting the load centrally through (50 mm x 50 mm x 6 mm) Angle and 20mm x 3mm Flat inserted into the wall. The Area of the platform is of suitable size as per Machine configuration & load with adequate service access as per direction of EIC. The design of platform structure to be approved by EIC. |
| 14 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for installation, per storey of building per vertical run. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender