Tender For Repair/ Replacement Of Internal Wiring ,Sub Main Wiring , Control Dbs Mcbs U/S Fitting Fixtures, Geyesers, Exhaust Fan Ceiling Fan And Connected Misc Items Of Works At Various Md/ Otm Accn, Repair/ Maintenance Of Security /Street Lights ,Floods Light, Automatic Timer Switch , Pole Painting And Connected Misc Items Of Work And Repair/Maint Of Dg Sets, Dg Sets Panel ,E/M Eqpt And Allied Works Of 6 Vikas In Ravangla Mil Stn Under Ge 867 Ews
BOQ
| Sl. No. | Item Description |
| 1 | M/L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 3.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 3.0 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly for one light/fan/bell point controlled by one switch 6 Amp one way complete all as specified. |
| 2 | All as per item no. 01 above but one 3 pin socket outlet on same board with other switches. |
| 3 | All as per item no. 01 above but one 3 pin switch socket combination 6 amp on the independent board. |
| 4 | All as described as per item No 1.00 above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board. |
| 5 | S & F in replacement under repair switch piano flush type single pole, one way 6amp complete all as specified. |
| 6 | S & F in replacement under repair switch socket combination 5 pin 6 amp complete all as specified. |
| 7 | S & F in replacement under repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified. |
| 8 | S & F in replacement under repair ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 230 volts ISI marked. |
| 9 | S & F in replacement under repair lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting. |
| 10 | S & F in replacement under repair flush type bell push 6 amp duly marked for bell complete all as specified. |
| 11 | S & F in replacement under repair Electronic ding dong bell AC 230V single pole complete all as specified. |
| 12 | Supply and fix in repairs LED polycarbonate T8 tube 20watt, CCT-3000/4500/6500K, 2150 lm polycarbonate housing in Opal finish provides glare free uniform light 1800lm 30000 burning hours inbuilt aluminium heat sink, surge protection-3KV, single sided completion connection Complete all as specified and directed. Cat Part No PHOTONULTRAE2.01213T8SSTL20WLED865SPC of Havells or equivalent in Crompton/Philips/Wipro |
| 13 | Material and labour for point wiring (concealed type) with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia, medium grade with all necessary fittings, surface wiring , for light /fan/bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/ on PVC Boxes for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. complete all as specified or directed including testing on completion including making good surface by plastering and paintaing. |
| 14 | All as per item no.13 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on independent board. |
| 15 | All as per item no.13 here – in – before but for one switch socket outlet 15 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable. |
| 16 | S & F in replacement under repair fan regulator electronic type 100Watt 20V-50Hz as directed by Engr-in-charge. Make: Ancho cat No 38660 or equivalent |
| 17 | S & F in replacement under repair ceiling fan capacitor 2.5 mfd all as specified and directed. |
| 18 | S & F Energy efficient LED tube light fitting 4\\", 1x18/20 watt, with bipin holders, connector block, CCT - 6500K, system output lumen not less than 1800lm, aluminium housing, surge protection range 3KV including connecting up with PVC insulated 3 core sheathed 0.5 sqmm copper conductor two numbers PVC mounting blocks for fixing of fitting complete all as specified and as directed by Engineer-in-charge. Make : Make : Batten : Cat part No- DMLN1LT8-16 and Tube Rod of Make Crompton Cat Part No : LTT8-20 or equivalent in Havells/Philips/Wipro |
| 19 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old u/s light fitting complete all as specified and directed. Make : Crompton Cat part No \\"LDL-10-CDL\\" or equivalent in Philips/Havells. |
| 20 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old u/s light fitting complete. Make : Crompton Cat part No \\"LBH-10-CDL\\" or equivalent in Philips/Havells. |
| 21 | Supply and fixing LED Building Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down old u/s light fitting complete all as specified and as directed. Make : Crompton cat Part No \\"LST-25-CDL-M\\" or equivalent in Philips/Havells. |
| 22 | S & F in replacement under repair 9W LED Bulb suitable for B22 holder . System Efficacy should be > 85 lm/ W. PF > 0.9, The Lamp Should have Cool Daylight Color temp of 6500K, lumen output >800 lm. Make: Philips/Wipro/Crompton |
| 23 | Taking down existing UNSV copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc |
| 24 | Dismantling and taking out submain wiring 2/3/4/6 wire of any size, segregating for material for reuse, making good disturbed surface of walls/floors to match with existing surface and taking out from site all as directed by Engineer-in-Charge. |
| 25 | Dismantling damaged wooden boards of Electric meter by disconnecting all electric connection and S&F rectangular teak wood board of size 30cm x 25cm x 5cm deep with smooth hylem sheet top 5mm thick for mounting Electric Meter.MCB DB including making holes for incomming and outgoing wires and making necessary electrical connections incl painting of boards complete all as specified and directed. |
| 26 | S & F in replacement under repair MCB DB factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240V SPN 12 way for fixing of MCBs/Isolators/RCCBs etc completed. Make : Legrand/Schneider/L&T/C&S |
| 27 | All as per item No.26 here – in – before but SPN 8 way. |
| 28 | All as per item No.26 here – in – before butSPN 4 way. |
| 29 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete including taking down old unserviceable MCB all as specified and as directed. |
| 30 | All as per item No here – in – before but SPN 40 to 63 Amps 'C' curve complete all as specified. |
| 31 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louver complete all as specified. |
| 32 | M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 33 | M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. NOTE : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 34 | Supply and fixed on surface Rigid non metallic PVC casing caping of size 25mmincluding of all tee, bends, elbows and fixing accessories such as couplers, lock nuts,saddles, pipe hooks including taking down old broken PVC casing caping and making good surface complete all as specified and directed by Engr-in-Charge. |
| 35 | All as per item no 34 here – in – before but for 20mm complete all as specified. |
| 36 | M&L earthing complete with galvanized steel earth plate electrode 600mmX600mmX6mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, CI Cover with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe15mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc incl taking down old u/s earthing all as specified and as directed. |
| 37 | Refixing of old serviceable light fitting of any description including clamps etc as required complete all specified and directed. |
| 38 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm. Make : Crompton Greaves, Model : BRISK AIR , or equivalent in USHA/ Bajaj/ Crompton / Havells. Note: Old UNSV ceiling fans will be deposited to MES Store at Rhenock. |
| 39 | S&F Sheet Metal Enclosure with socket plug top and MCBs double pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V, 20 Amps incl taking down old u/s metal socket complete all as specified. make : ABB/L&T/C&S/Legrand/Havells |
| 40 | S&F Decorative, wall mounting fixture in durable plastic body & designer mesh in gold finish suitable for 9 W retrofit CFL including necessary connection with 0.5 sqmm PVC sheathed 3 core copper cable and 14W LED lamp incl taking down old u/s light fitting complete all as specified. Make : Crompton/Havells/Philips/Wipro |
| 41 | Taking down existing unserviceable service cable of any size and S&F 1100 volts grade heavy duty PVC insulated stranded aluminium conductor cable of cross-sectional area 10 Sqmm size (one twin core cable flat or circular, served with inner sheathing of PVC tape and overall PVC sheathed) in service connections, suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire and testing on completion complete all as specified and as directed by the Engineer-in-Charge. MAKE : FINOLEX/PLAZA/ HAVELLS/ POLYCAB/KEI. |
| 42 | Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for inspection compete Including back plate heating element inner copper tank etc. De-scaling back plate and heating element by cleaning with Sulfuric acid/ de-scaling compound and re-assembling of Geysers after repairs carrying out and re-fixing in same position (Replaced items such as spares measured and paid separately)in relevent item including making good to walls with CM (1:3) or PCC (1:2:4) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc all as directed by the Engineer-in Charge. Note :- Any type of rubber gasket , rubber washer, screws , insulator tape required in work deem to be included in the rate. |
| 43 | All as per item No 42.00 herein before but for descaling / cleaning the inner tank including denting and brazing the leakage joints / points till the leakage stop including carrying out minor repair of outer body surface, bottom and top cover complete all as specified and as directed. Note :- Any damage if occured during the process of cleaning the geysers will be made good by contractor at no extra cost. |
| 44 | M&L for 1.5 KW capacity Heating Element, triangular type including making electrical connection incl taking down old u/s heating element complete all as directed by the Engineer-in-Charge. |
| 45 | All as per item no 44.00 but of capacity 2.0 KW complete all as specified. |
| 46 | Supply & fixing PVC connection heavy duty with brass/PTMT nuts of reqd length not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete for cold water.incl taking down old u/s connection complete all as specified. |
| 47 | Supply & fixing hot water outlet connection made of brass chromium plated with Union rubber washer suitable for 15 mm bore GI pipefor hot water incl taking down old u/s item complete all as specified. |
| 48 | Supply & fix in replacement of thermostat (automatic cut of) of existing type & make, 15 Amps, 230/250 volts AC ISI marked complete all as specified. |
| 49 | Supply & fix in replacement of indicator lamp assembly LED type RED/GREEN for geyser complete all as specified. |
| 50 | S&F in replacement plug top 15 Amps240 Volts complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F of electric storage type water heater of 25Ltr capacity, 2000Watt, vertical type including necessary angle cock, inlet and outlet water connecting pipe and electric connection complete all as specified and as directed by Engineer-incharge. Make : Usha/ RACOLD/BAJAJ/Crompton |
| 52 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete. make Havells cat part No \\"VENUSNEOHE2X2R36WLED830PIRSENSOR\\" or equivalent make in Crompton/Havells/Philips |
| 53 | Supply & fixing LED PL Lamp to the existing light frame or as per site including necessary connection and dismantling of existing defective fitting complete. similar to Make Philips, cat part No. LED PL-L 18W, 6500K 2G11 or equivalent make in Crompton/Havells. |
| 54 | S&F LED Driver for existing ceiling lights up to 36 W all as specified and directed. Make : Crompton/Havells/Philips |
| 55 | M&L in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed by Engr-in-charge. |
| 56 | All as per item No 55 here-in-before but of size 175 x 100 x 50 mm complete all as specified. |
| 57 | All as per item No 55 here-in-before but of size 250 x 200 x 50 mm complete all as specified. |
| 58 | M&L for sheet metal enclosure double door TPN DB 4 Way all as specified and directed by Engr-in-Charge.Make - Havells/Legrand/Seimen/L&T |
| 59 | Taking down of exhaust fan upto 450/300mm sweep, opening, replacement of unserviceable accessories, servicing, oiling, greasing, complete overhauling of fan and re-assembling and testing complete for efficient functioning after fixing / hanging in position from ceiling rose to fan complete as directed. (Note : gun metal bush, bearing will be measured and paid under relavant item here-in-after). |
| 60 | Supply only gun metal bush of sizes suitable for exhaust fan upto 450 mm sweep. |
| 61 | Supply only ball bearing No 6203 suitable for fan of existing make type & sweep complete Make:- NBC/SKF/TATA |
| 62 | Checking of exhaust fan (of any sweep) by replacing unserviceable capacitor/ tightening the loose connections if any including testing complete all as directed by Engr-in-Charge. (Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after) |
| 63 | M & L for painting of exhaust fan carefully with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as directed. |
| 64 | M&L for shifting of exhaust fan from one place to another including making hole at new place and filling of hole at old place including all necessary electric connection, brick work, plastering and 2 coat of painting of size 150, 200, 250 and 300mm dia all as specified and directed. |
| 65 | Supply and fixing LED round/square shape 6 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 66 | Supply and fixing LED round/square shape 12 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 67 | Supply and fixing LED round/square shape 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 68 | Supply and fixing LED round/square shape 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 69 | S & F INVETER LED Tube light fitting 20 Watt with square profile and polycarbonate channel. lITHIUM Ion battery with charging time 8 to 10 hrs and back up time upto 4 hrs LED light source 6500k with uniform light output,with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with complete with all as specified and directed. |
| 70 | S&F in repairs, LED 9W Inverter Bulb, 230 Volts AC supply, all as specified and directed. |
| 71 | Taking down unserviceable fitting of any type or any wattage i.e. 100/90/80/72/60/45/30/25 Watt energy efficient street light fitting, identifying the fault, repair / replacement of old unserviceable accessories with new accessories, reassembling and make the street light fitting functional and refixing in existing location including three core copper PVC insulated conductor of 1 sqmm size (nominal area) of suitable length to connect the lumaniries to overhead conductor / existing lines complete all as specified and directed . Note : Spares part/material required for repair to street light fitting shall be measued and paid separtely under relevent items as supply only. |
| 72 | M&L for 1100 volts grade heavy duty cable PVC insulated and FR PVC rounded sheathed, copper conductor (flexible) industrial cable, conforming IS: 694 of size 1.5 sqmm 3 core laid along pole from junction box to light fitting complete all as specified and directed. Make : Polycab/Havells/KEI |
| 73 | S&F in replacement of street light driver of 25 watt to 50 watt, 230V,50Hz suitable for operation over voltage range of 140V to 270V by emoving from existing position complete all as specified and direcred by Engr-in-Charge.Make : Surya/Crompton/Havells/Philips/Wipro |
| 74 | S&F in replacement of street light driver of 55 watt to 100 watt, 230V,50Hz suitable for operation over voltage range of 140V to 270V by emoving from existing position complete all as specified and direcred by Engr-in-Charge.Make : Surya/Crompton/Havells/Philips/Wipro |
| 75 | M & L in for DK Thermoplastic cable junction boxes IP 65 with of size 300x200x105 of metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 No. of single pole MCBs 6-32 amps,10KA and MCB TP 6-32 amps, 10 KA, ‘C’ series 01 No inside the box incl taking down old u/s junction box complete all as specified and directed. Make : Sintex/Hensal or equivalent approved by GE. |
| 76 | S&F Busbar Chambers 4 way 100 Amps outdoor type (IP 65/66) pole mounted including provision of fixing on pole by means of suitable size of clamps with nut and bolts including necessary connection including taking down of old u/s bus bar completed all as specified and as directed. Make Havells cat part No IHBC010004 or equivalent make of SMC/Hensel |
| 77 | S&F in repairs LED street light fittings, IP-66, 70 watt including bracket made out of 40 mm dia light grade GI pipe not less than 1.2 mtr long bend to shape duly fixed with MS clamps of 3mm thick, nut, bolts etc complete fixed to steel tabular poles including electrical connection complete with 3 core 1.5 Sqmm PVC sheathed stranded copper wire ISI marked from junction box to fitting all as specified and as directed, Make : Crompton,/Havells/Bajaj/Philips |
| 78 | Supply and Laying in replacement u/s cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables of Size of 16 Sqmm 4 core (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in Trench with the help of shadel of following size as required at site, Make : MESCAB/HAVELLS/POLYCAB/GLOSTER/KEI |
| 79 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge. |
| 80 | Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed. |
| 81 | Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed. |
| 82 | M&L for sand cushioning to U/G cable in layers in trenches complete all as specified and directed. Note :- Only Puned layers shall be measured for payment |
| 83 | M&L for well burnt bricks, sub class 'B' bricks of size 250mmx125mmx75mm, best quality locally available laid flat dry in trenches for cable protection complete all as specified and as directed. |
| 84 | M&L for painting of steel tubular pole of any size , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level and numbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ) complete all as directed. |
| 85 | S&F in repair GI Pipes 25mm bore light grade in any position for protection of cable fixed at pole/laid under road , nallah, crossing walls under floors etc complete all as specified and directed.Make : TATA/BANSAL/JINDAL or equivalent |
| 86 | S&F in repairs automatic street/security light switch of rating 8 KW in three phase using nature switch for automatic switching of street lights based on lux level on nature light. The sensor (Nature Switch) along with suitable power contactor, MCB and supprot terminals should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade special moulding compound (Polycarbonate) conforming to IP 54 complete all as specified and as directed. along with each contactor 25-32 Amps , Incoming-Outgoing MCBs (03 Nos each) rating : 32 Amps, circuit wiring min 10 sqmm. Model - SWADEEP - 02EC8KW3P. MAKE- 1.Nature-Nature Switch : Kakatiya Energy systems Pvt. Ltd / HEALER / BAJAJ / Havells 2.Contactor : BCH / L& T / Schneider 3.MCB : Hager / Schneider /L&T/C&S 4. Circuit wiring : Finolex / Polycab or equivalent. |
| 87 | Dismantling/taking up or down roof conductor/down conductor of aluminium strip any size/condition with insulators from the Bldg for replacement of insulator/conductor etc and segregating serviceable conductor for re-use at site and removal of unserviceable conductor and insulators from site of work all as specified and as directed. |
| 88 | Fixing only serviceable roof conductor/down conductor any type/size retrieved under item No 6.00 above on roof wall on porcelain or epoxy spacer insulator (insulator measured and paid separately under relevant item) all as specified and as directed. Note :- Rates quoted by the contractor are deemed to be included for cutting ,jointing pieces ofstrip with nut bolts etc. complete all as specified and directed. |
| 89 | S&F aluminum strip 25 x 3.15 mm complete with saddles and fixing screws for roof / down conductor on porcelain/epoxy spacer insulatoror fixed on GI Pipe all as specified and as directed (Spacer insulator measured and paid separately under relevant items) . Note :- Rates quoted by the contractor are deemed to be included for cutting ,jointing pieces ofstrip with nut bold etc. complete all as specified and directed. |
| 90 | S&F porcelain/epoxy white / brown / green spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing roof conductor / down conductor of lightning conductor complete all as specified and as directed. |
| 91 | Fixing only porcelain/epoxy white / brown / green spacer insulator retrieved under item Ser No. 17.00 above with one GI stud bolt with nut and washer for holding / fixing roof conductor / down conductor of lightning conductor complete all as specified and as directed. |
| 92 | S&F single pointed air termination aluminium rod 12-mm dia 300 mm long with fixing arrangement including dismantling of old unserviceable/ deshaped conductor and removed from site of work complete all as specified and as directed. |
| 93 | Fixing only in repair single pointed air termination aluminium rod 12-mm dia 300 mm long with fixing arrangement including dismantling of old unserviceable/ deshaped conductor and removed from site of work complete all as specified and as directed. |
| 94 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in-Charge. |
| 95 | S&F LED type 24 watt all in one Solar LED street light in aluminium Die cast housing with IP 68 protection lumen output> 3000 lumens with 30 LED chips of 1 watt each system efficiency should not less than 175 lumens /watt CRI -70(+/-%%) CCT -5700 K (+/-5%) UV stabilized polycarbonate cover for better should be used with battery capacity >170wh integrated MPPT charger with driver luminaire should have built in PIR sensor foxture tilt angle should be 0-15 degree adjustable input voltage -12V DC to 14V DC LED burnung hours should be >50000 Hrs @ L70 luminaire should have charging & discharging LED indicator with 110watt poly, solar PV module as per MNRE standard with RFID (25 years performance warranty) .Incl pole with light arm bracket. Note - Light should be with 5 Years warranty Make : Philips/Havells/RS Solar/Crompton |
| 96 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as per Crompton Make : LPTO-40-CDL/M or equivalent in Havells/Philips or equivalent |
| 97 | Supply and fixing LED Bollard with robust design and efficient light distribution 10W 230 watt volts AC outdoor type with decorative with IP 65 protection with impact and corrosion resistant complete all as per Crompton Make : LBLSR-10-CDL or quivalent in Havells/Philips or equivalent |
| 98 | M & L for Plain Cement Concrete (1:3:6) mix type C2 (using 40 mm graded stone aggregate) in foundation, filling and mass-concrete etc for pole, stay etc all as specified and directed by Engr-in-charge. |
| 99 | M & L for Plain Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregae) as in copping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-in-charge. |
| 100 | M&L for Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of DG set of 82.5 KVA DG Set i,e. Engine, alternator etc under GE 867 EWS all including consumables items like cotton waste cloth kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chare of maintenance schedule. (i) Change engine oil. (ii) Changing of oil filters, fuel filters screen filters assy. (iii)Changing of water filter. (iv) Making up coolant (v) Clean alternator winding in position by forced air and internal surfaces lubricate (vi) Tightining of all nut bolts. (vii) Greasing of all points.(viii) Checking of any leaking in fuel & oil lines [Note - Accessories / spares/ new engine oil required for replacement will be measured and paid separately under respective items of schedule ‘A’ as supply only] |
| 101 | All as per item No. 101 above but 45 KVA DG Set complete all as specified and directed. |
| 102 | All as per item No 101 above but 15 KVA DG Set complete all as specified and directed. |
| 103 | Supply only new Engine oil 15 W 20 Make : HP/BP/Indian |
| 104 | Supply only fuel filter suitable for 62.5 KVA DG Set. |
| 105 | Supply only fuel filter suitable for 45 KVA DG Set. |
| 106 | Supply only fuel filter suitable for 15 KVA DG Set. |
| 107 | Supply only lubricant oil filter suitable for 62.5 KVA DG Set. |
| 108 | Supply only lubricant oil filter suitable for 45 KVA DG Set. |
| 109 | Supply only lubricant oil filter suitable for 15 KVA DG Set. |
| 110 | Supply only air filter element suitable for 62.5 KVA DG Set. |
| 111 | Supply only air filter element suitable for 45 KVA DG Set. |
| 112 | Supply only air filter element suitable for 15 KVA DG Set. |
| 113 | Supply & top up water coolant in radiotor of DG set of any capacity any make, Make : TVS Girling/volvo line or of equivelent make all as directed by Engr-incharge. |
| 114 | Cleaning of the fuel tank of DG sets of 82.5/ 62.5/45/15 KVA capacity after decaning the diesel, after through cleaning with kerosene oil including replacement of level indicator pipe complete all as directed by Engr-incharge. |
| 115 | M & L for cleaning/washing the radiator complete all as directed at site by Engr-in-charge |
| 116 | M&L for replacement of Radiator hose Kit suitable for 82.5/62.5/45/15 KVA DG set all as specified |
| 117 | M&L for replacement of Fan belt suitable for 82.5/62.5/ KVA Gen set. |
| 118 | M&L for replacement of Fan belt suitable for 45/12.5 KVA Gen set. |
| 119 | M&L for replacement of Fan blade suitable for 82.5/62.5 KVA Gen set. |
| 120 | M&L for replacement of Dynamo 12 Volts, 35 amps as per existing in 25 KVA DG set. |
| 121 | S & F for selector switch/ rottary switch as per existing make. |
| 122 | Supply and fix in replacement of Lid acid battery 12 volt 90 AH suitable for 50/ 40 KVA DG set all as specified. Make : Amaraon/Exide/SF |
| 123 | Supply and fix in relacement of Power contactor 4 pole 415 Volt, 160Amps Model no L&T MCX-32 including all electric cionnections as per existing make. |
| 124 | Supply and fix in relacement of Power contactor 4 pole 415 Volt, 63Amps Model no L&T MCX-12 including all electric cionnections as per existing make. |
| 125 | Supply and fix in relacement of Spare coil for ontact unit 2 pole, 415 Vot, 10A Model no L&T MCX-32 including all electric cionnections as per existing make. |
| 126 | Supply and fix in replacement of old unserviceable CT 100/5A ratio, 5 VA, CL-1 of DG set Panel /Feeder pillar box incl connecting, disconnecting and testing complete all as directed at site. |
| 127 | Taking out governor speed control system, cleaning servicing and overhauling the system complete, refitting and setting /adjusting the governor, speed including testing for 62.5 KVA DG Set complete all as specified and directed. |
| 128 | M&L for servcing the starting panel of DG Set, cleaning and adjusting the time setting, cleaning and tightening the lose connection of contactor, timer, HRC fuse ammeter, voltmeter etc and making for smooth functioning of the starting operation of 82.5 to 45 KVA cap complete all as specified and directed. |
| 129 | M&L in replacement of u/s MCCB o4 pole of capacity 63 to 100 Amps 415 Volts with breking capacity 16 KA complete all as specified and directed by Engr-in-charge. Make:- L&T/ Legrand/ Scheinder/ Siemens |
| 130 | M&L in replacement of u/s MCCB 3 pole 125 Amps adjustable type, 415 Volts, with breking capacity 36 KA complete all as specified and directed by Engr-in-charge. Make:- L&T/ Legrand/ Scheinder/ Siemens |
| 131 | M&L in replacement of u/s MCCB 4 pole 200 Amps adjustable type, 415 Volts, with breking capacity 36 KA complete all as specified and directed by Engr-in-charge. Make:- L&T/ Legrand/ Scheinder/ Siemens |
| 132 | Supply and fix MCB, Tripple Pole & Neutral, 40-63 Amps, 415 volts, 50 Hz, 16kA complete all as specified and directed by Engr-in-Charge. Make- Legrand, Siemens, Schinder, Havells. |
| 133 | Material and labour for Load balancing of LT panel connected in DG set in all three phases of all outgoings complete with all as specified under:- a) Taking of load of LT panel out going cables with the help of tong testing three times in a day to assess maximum unbalance of load. (b) To disconnect the LT cables/ TC wires and reconnect the same as per the load of the MCCB to balance the circuit. (c) Take the building wise load on the panel and make the load balance at bldg end. |
| 134 | Material and labour for Reconditioning and reconnecting of AMF panel in Various type of DG set including removing of rust particles ad corrotion/ carbon from panel connected items likepower contactor, CTs, MCCB/ MCBs all as specified an directed by Engr in charge. |
| 135 | Supply and fix in Replacement of Off load Change over switch 4 pole, 415 Volt, 100 Ams capacity including all incomming and outgoing electric connectios all as specified. |
| 136 | M&L submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 10 Sqmm (nominal area) each and one single core 10 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping complete all as specified and directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate. |
| 137 | S&F TPN DB with suitable for TPN MCB incomer, double door (IP-54), 6 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed. |
| 138 | Supply and fix MCB, Tripple Pole 63 Amps, 415 volts, 50 Hz, 16kA, 'C' curve complete all as specified and directed by Engr-in-Charge. Make- Legrand, Siemens, Schinder, Havells. |
| 139 | S&F MCB, SP,240 volts, breaking capacity 10 KA, rating, 'C' curve 40 to 63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells |
| 140 | Supply and fix sheet metal enclosure double door 4 way DBs SPN, 240V with 200 Amps rated bus bars double door complete in and including of existing electric connection/ circuit all as specified and as directed. Make : L&T/ Legrad/ Semens |
| 141 | S&F Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door, built in 200 Amps bus bar complete suitable for 240 Volts, AC, 50 Hz complete in and including of existing electric connection/ circuit all as specified and as directed. Make: L&T / Legrand /C&S/Havells |
| 142 | S&F MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells |
| 143 | S&F MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells |
| 144 | S &L sub class B bricks having minimum compressive strength 75 Kg/Sqcm laid in trenches for cable protection etc complete all as directed by Engineer -in-Charge. |
| 145 | Cutting through existing bituminous road /PCC /floor /approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, M&L complete all as specified. |
| 146 | Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site cable size of size of 95 Sqmm 3.5 Core complete all as specified. |
| 147 | All as per item No 146 here-in-before but 50 Sqmm 3.5 Core complete all as specified. |
| 148 | All as per item No 146 here-in-before but 35 Sqmm 3.5 Core complete all as specified. |
| 149 | All as per item No 146 here-in-before but 25 Sqmm 4 core complete all as specified. |
| 150 | Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed by Engineer-in-Charge. |
| 151 | M&L for Reconditioning/ recharging of existing earthing including excavation of earth work upto 1.5 mtr from ground level and removing of soil and old materials near from earthplate as a distance of 300 mm and add salt and coal in a layer of 15 mm from bottem level upto earth plate, reassembling of funnel and water pipe, returning filling of soil and fifing of eath chamber all as specified. |
| 152 | Dismantling of servo controlled voltage stabilizerby disconnecting all internal electric connection and disconnecting of LT connection earthing lead and taking down carefully defective servo controlled voltage stabilizer of capacity 75 KVA, 415 Volts, from sub station and after necessary repair and installing the same servo controlled voltage stabilizer to its original position including reconnection of all electrical cables wires and earthnig connection complete all as specified and directed by Engr-in-Charge. |
| 153 | S&F in replacement of top cover gasket sheet as per existing size and complete for servo controlled voltage stabilizer of capacity 75 KVA complete all as specified and as directed. |
| 154 | Reassembling of servo controlled voltage stabilizer including heating, varnishing testing and commissioning complete all as specified and as directed by Engr-in-Charge. |
| 155 | S&F in in repairs controller circuit board suitable for 75 KVA servo controlled voltage stabilizer complete all as specified and as directed b Engr-in-Charge. |
| 156 | S&F in repair synchronising motor suitable for 75 KVA servo controlled voltage stabilizer complete all as specified and as directed by Engr-in-Charge. |
| 157 | S&F in repair contactor suitable size for 75 KVA servo controlled volatge stabilizer complete all as specified and as directed by Engr-in-Charge. |
| 158 | M&L for repair of voltage stabilizer upto 5 KVA including replacemnt of small parts like fuse, circuit board, inbuit transformer, relays etc all as specified and directed. |
| 159 | Supply and fix in replacement of detoriated/ damaged Battery lead with new cable assembly battery lead Cat part no:0416-0639 Make cummins or equivalent Finolex/Havells |
| 160 | Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 82.5/62.5/45 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN Code 998729 to the entire satisfaction of Engr-in-charge. Please Enable Macros to View BoQ information |
| 161 | Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 82.5/62.5/45 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN Code 998729 to the entire satisfaction of Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender