Drinking Water Supply and Sanitation Local Bodies Closing in 4 days TDR #56848390

Tender For Repair And Maintenance For Existing Mini Power Pump Motor In Ward 1-18 In Ariyalur Municipality.

Issued by Local Bodies · Ariyalur, Tamil Nadu
Tender Value
4.80 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
4 days left
EMD
4800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ariyalur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance For Existing Mini Power Pump Motor In Ward 1-18 In Ariyalur Municipality.

BOQ

Name of Work:- REPAIR AND MAINTENANCE FOR EXISTING MINI POWER PUMP MOTOR IN WARD 1-18 IN ARIYALUR MUNICIPALITY.
Sl. No. Item Description
11.5 HP Single phase submersible motor completed coil rewinding as per standard specification and proper termal connection including all cost of materials and labour charges etc,. Complete.
21.5 HP Single phase submersible pump full service complete replacement of pushes sleves,defuser,impler made to good work condition of pump including all cost of materials and labour charges etc,. Complete.
3Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %, 50 HZ +/- 5 % .(20 lpm X 80 m)
420 lpm X 90 m
5Supply and delivery of 3core 2.5mm flat type Copper cable to IS 694/1990 including of loading and unloading charges etc., complete
6Supply and delivery of direct online starter confirming to IS13947 and IEC 947 suitable KW rating for operation in AC/single Phase/50HZ(± 5%) and 230 V(±10%) ncluding Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately)(1.5 Hp)
7Labour charges for the erection of submersible pumpset submersible cable with proper clamps upto the starter required depth valves erection clamps, pressure gauges Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., days..(up to 5hp)
8Removal of centrifugal pumpset/ jet pumps/ submersible pumpsets and its accessories from borewell/ open well for attending repairs 50% of the rates mentioned under item 17 (a), (b) and (c) may be allowed for the respective Horse power
9Re-erection of centrifugal pumpsets, jet pumpsets and its accessories into the borewell/ openwell after attendingthe repairs 50% of the rate mentioned under item 17 (a), (b) and (c) may be allowed for respective Horse power
10Supply and delivery of PVC pipe and specials complete etc,.(a) 32 mm dia PVC pipe)
11b) PVC Screw Down Tap Heavy Type 20mm dia
12c) 32 mm dia PVC Nipple
13d) 32 mm dia PVC Elbow
14e) 32 mm dia PVC Coupler
15d) 32 mm dia PVC Tee
16Supply and delivery of UPVC pipe and specials complete etc,.(a) 32 mm dia UPVC Valve)
17b) 32 mm dia UPVC Union
18c) 32 mm dia UPVC Elbow
19Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End
20Supply and fixing of 16 Amps Porcelain Fuse Unit (500V)
21Supply and fixing of 32 Amps Porcelain Fuse Unit (500V)
22MINIATURE CIRCUIT BREAKERS 240 V/415 V 50HZ AC SUPPLY SUITABLE FOR BOTH LIGHTING AND MOTOR CIRCUITS (Single pole 6A to 32A,10 KA)
23Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,(1000 ltr Tank) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56848390
AUTHORITY Local Bodies
TENDER VALUE 4.80 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Repair And Maintenance For Existing Mini Power Pump Motor In Ward 1-18 In Ariyalur Municipality.
Basic Detail
Tender No 662/2026/E1
Bidding Type Tender
Location
City Ariyalur
State Tamil Nadu
Key Dates
Publish Date 05 Aug 2026
Submission Date 24 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 4.80 Lakhs
Tender Fee Ref. Documents
EMD 4800
Exemption Not Available
Document List
BOQ_831061.xls
ddf210fe-1eb2-49d0-b20f-9148065f5ee5.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_831061.xls

html

ddf210fe-1eb2-49d0-b20f-9148065f5ee5.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail