Tender For Operation, Running, Maintenance Of 25Mldttp At Sector-20 Panchkula And 5 Nos. Boosting Stations, Including Repair Spare Parts Etc., Chemical Dosing And Chlorine Gas And Operation And Maintenance Of Distribution Pipe Line Di/Hdpe In Panchku

Issued by Government Departments · Panchkula, Haryana
Tender Value
5.86 Crore
Estimated cost
Bid Submission
27 Aug 2026
3 days left
EMD
11.74 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Operation, Running, Maintenance Of 25Mldttp At Sector-20 Panchkula And 5 Nos. Boosting Stations, Including Repair Spare Parts Etc., Chemical Dosing And Chlorine Gas And Operation And Maintenance Of Distribution Pipe Line Di/Hdpe In Panchkula And Panchkula Extension Complete In All Respect.

BOQ

Name of Work:- Operation, running, maintenance of 25MLDTTP at Sector-20 Panchkula and 5 nos. Boosting Stations, including repair spare parts etc., chemical dosing and chlorine gas and Operation and maintenance of distribution pipe line DI/HDPE in Panchkula and Panchkula extension complete in all respect.
Sl. No. Item Description
1Operation of 25MLD TTP and 5 nos. Boosting Stations along other related units comprehensive maintenance including expert visit charges.
2Maintenance, Spare Repair and maintenance of ACB, MCCB, CT Meters contactor, capacitors etc. complete per annum for Machinery, Motor and Pumping Machinery, electrical machinery including starter work
3Supply, erection, Testing and commissioning of Activated Carbon Filter for 1MLD capacity complete in all respect and entire satisfaction of Engineer-in-Charge.
4Supply, erection, Testing and commissioning of Activated Carbon Filter for 2MLD capacity complete in all respect and entire satisfaction of Engineer-in-Charge.
5Supply and dosing of chemicals i.e. Alum, Chlorine as per requirement to purify 25MLD TTP at Sector-20, Panchkula.
6Repair of control panel 10 hp to 60 hp at TTP Boosting station at Panchkula.
7Repair of Tertiary Treatment Plant water (TTP) HDPE pipe line leakages by replacing the cracked portion including cost of giving heat treatment with the help of heater late, rent of Gen Set, cost of electric diffuser HDPE joint-2 nos., excavation, taking out sludge, dewatering, cutting, stringing, jointing, testing complete in all respect for 90mm OD HDPE pipe line (As per market rate).
8Repair of Tertiary Treatment Plant water (TTP) HDPE pipe line leakages by replacing the cracked portion including cost of giving heat treatment with the help of heater late, rent of Gen Set, cost of electric diffuser HDPE joint-2 nos., excavation, taking out sludge, dewatering, cutting, stringing, jointing, testing complete in all respect for 120mm OD HDPE pipe line (As per market rate).
9Repair of Tertiary Treatment Plant water (TTP) HDPE pipe line leakages by replacing the cracked portion including cost of giving heat treatment with the help of heater late, rent of Gen Set, cost of electric diffuser HDPE joint-2 nos., excavation, taking out sludge, dewatering, cutting, stringing, jointing, testing complete in all respect for 160mm OD HDPE pipe line (As per market rate).
10Repair of Tertiary Treatment Plant water (TTP) HDPE pipe line leakages by replacing the cracked portion including cost of giving heat treatment with the help of heater late, rent of Gen Set, cost of electric diffuser HDPE joint-2 nos., excavation, taking out sludge, dewatering, cutting, stringing, jointing, testing complete in all respect for 200mm OD HDPE pipe line (As per market rate).
11Repair of Tertiary Treatment Plant water (TTP) HDPE pipe line leakages by replacing the cracked portion including cost of giving heat treatment with the help of heater late, rent of Gen Set, cost of electric diffuser HDPE joint-2 nos., excavation, taking out sludge, dewatering, cutting, stringing, jointing, testing complete in all respect for 250mm OD HDPE pipe line (As per market rate).
12Repair of Tertiary Treatment Plant water (TTP) HDPE pipe line leakages by replacing the cracked portion including cost of giving heat treatment with the help of heater late, rent of Gen Set, cost of electric diffuser HDPE joint-2 nos., excavation, taking out sludge, dewatering, cutting, stringing, jointing, testing complete in all respect for 315mm OD HDPE pipe line (As per market rate).
13Repair of Tertiary Treatment Plant water (TTP) HDPE pipe line leakages by replacing the cracked portion including cost of giving heat treatment with the help of heater late, rent of Gen Set, cost of electric diffuser HDPE joint-2 nos., excavation, taking out sludge, dewatering, cutting, stringing, jointing, testing complete in all respect for 450mm OD HDPE pipe line (As per market rate).
14Rates for repair and Rectification of lekage/Crack CI/DI/AC Pipeline of 150mm dia water supply pipe line including hydraulic test with all CI/DI special i.e. M.G Collar, pipe, joint, nut and bolt, excavation and back filling the same and all other works contingent thereto etc. complete in all respect as per site requirement and entire satisfaction to the Engineer-in-charge.
15repair and Rectification of lekage/Crack CI/DI/AC Pipeline of 200mm dia water supply pipe line including hydraulic test with all CI/DI special i.e. M.G Collar, pipe, joint, nut and bolt, excavation and back filling the same and all other works contingent thereto etc. complete in all respect as per site requirement and entire satisfaction to the Engineer-in-charge.
16repair and Rectification of lekage/Crack CI/DI/AC Pipeline of 250mm dia water supply pipe line including hydraulic test with all CI/DI special i.e. M.G Collar, pipe, joint, nut and bolt, excavation and back filling the same and all other works contingent thereto etc. complete in all respect as per site requirement and entire satisfaction to the Engineer-in-charge.
17Repair and Rectification of lekage/Crack CI/DI/AC Pipeline of 300 mm dia water supply pipe line including hydraulic test with all CI/DI special i.e. M.G Collar,pipe, joint, nut and bolt, excavation and back filling the same and all other works contingent thereto etc. complete in all respect as per site requirement and entire satisfaction to the Engineer-in-charge.
18Repair and Rectification of lekage/Crack CI/DI/AC Pipeline of 400 mm dia water supply pipe line including hydraulic test with all CI/DI special i.e. M.G Collar, pipe, joint, nut and bolt, excavation and back filling the same and all other works contingent thereto etc. complete in all respect as per site requirement and entire satisfaction to the Engineer-in-charge.
19repair and Rectification of lekage/Crack CI/DI/AC Pipeline of 450 mm dia water supply pipe line including hydraulic test with all CI/DI special i.e. M.G Collar, pipe, joint, nut and bolt, excavation and back filling the same and all other works contingent thereto etc. complete in all respect as per site requirement and entire satisfaction to the Engineer-in-charge.
20Providing services of fitter/ fitter coolie / patrolman etc for Repair of 100.50km. Water supply pipe line in various sectors of Panchkula.
21For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 810 LPM @ /25 mtr. Head, 15hp including all accessories with warranty and all other work contingent thereto at TTP Boosting station Industrial area Ph-1 Panchkula.
22For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 756 LPM @ /45 mtr. Head, 20hp including all accessories with warranty and all other work contigent thereto at TTP Boosting station Industrial area Ph-I Panchkula.
23For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 542 LPM @ /25 mtr. Head, 10hp including all accessories with warranty and all other work contigent thereto at TTP Boosting station Industrial area Ph-II Panchkula.
24For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 1041 LPM @ /45 mtr. Head, 25hp including all accessories with warranty and all other work contigent thereto at TTP Boosting station Industrial area Ph-II Panchkula.
25For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 1241 LPM @ /35 mtr. Head, 25hp including all accessories with warranty and all other work contigent thereto at TTP Boosting station Nirjhar Vatik Sector-5 Panchkula.
26For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 1755 LPM @ /30 mtr. Head, 25hp including all accessories with warranty and all other work contigent thereto at TTP Boosting station Sector-3 Near PMDA office.
27For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 2497 LPM @ /50 mtr. Head, 50hp including all accessories with warranty and all other work contigent thereto at TTP Boosting station Sector-3 near dividing road 3/21 Panchkula.
28`For Supply, Erection, Testing and commissioning of Sewage Submersible Pump set Non- clog of capacity 934LPM @ /30 mtr. Head, 15hp including all accessories with warranty and all other work contigent thereto at TTP Boosting station 1 no. for TTP Boosting Station, Sector-3 near dividing road.2 nos. for STP Boosting Station, Sector-20, Panchkula.`
29[10.100.2]Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. [Through Rate]
30[11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works [Through Rate]
31[11.73.1]Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer`s specifications including appropriate priming coat, preparation of surface, etc. complete. 1. On steel work [Through Rate]
32[11.85.1]Painting over wooden/metal surface with acid proof paint of approved brand and manufacture of required colour to give an even shade : 1. Two or more coats on new work [Through Rate]
33[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate]
34[20.10.2]Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works 2. 100 mm i/d [Through Rate]
35[20.10.3]Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works 3. 150 mm i/d [Through Rate]
36[20.10.4]Extra for fixing sluice valves/flap valves socketed or flanged including cartage from stores or nearest Railway Station to site of works 4. 200 mm i/d [Through Rate]
37[21.97.16]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-100 grade and PN-6 for sewer. application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 16. Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-100 grade and PN-6 for sewer. application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.140 mm Outside Dia [Through Rate]
38[21.98.1]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 1. 200 mm Outside Dia [Through Rate]
39[21.98.2]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 2. 225 mm Outside Dia [Through Rate]
40[21.98.3]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 3. 250 mm Outside Dia. [Through Rate]
41[21.98.4]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 4. 280 mm Outside Dia [Through Rate]
42[21.98.5]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 5. 315 mm Outside Dia [Through Rate]
43[21.98.6]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 6. 355 mm Outside Dia [Through Rate]
44[21.98.7]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 7. 400 mm Outside Dia [Through Rate]
45[21.98.8]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 8. 450 mm Outside Dia [Through Rate]
46[22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore [Through Rate]
47[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]
48[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate]
49[22.14.2.2]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.2. Flexible pipe 40 mm dia [Through Rate]
50[22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate]
51[22.2.1]Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 1. White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer [Through Rate]
52[22.89.1]Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 1. 15 mm dia nominal bore [Through Rate]
53[22.98.2]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore [Through Rate]
54[23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required [Through Rate]
55[24.13.30]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 30. 25 Sq mm 3.5 core (Arm.) [Through Rate]
56[24.5.1.6]MISCELLANEOUS ITEMS 1.6. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 16 sqmm [Through Rate]
57[28.7]`Providing and applying waterproofing treatment using two component 100% solid content, hybrid polyurea/polyurethane, rapid curing and highly resilient fully bonded cured to membrane having a mixed density of 1.02g/l. Minimum recommended coverage rate is 1.5ltr/sqm in 2 coats to achieve a total DFT of 1.5mm. cured membrane shall exhibit: 1) Tensile strength ASTM D412 : )13 MPa 2)Tear Resistance ASTM D624C : 50 N/mm23) Shore A Hardness: 804)Elongation ASTM D412 : )450% 5( 1kg, CS 10 wheels,ASTM D 4060): 1.3 mg/1000 cycles 6) Service temperature: -20°C to plus 80°C 7) Resistant to Fire (EN13501-1)-Class E,d0 Manufacturers shall provide Certificate for Zero VOC, resistance to fire, 25 years life expectancy test certificate before the start of work. System includes supply , application and termination of coating all complete as per the manufacturer methodology.Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Prepare a side gola of 50X50 mm at the junction using polymer modified mortar. Providing and applying two component 100% solid content, hybrid polyurea/polyurethane membrane at coverage rate of 1.5ltr/sqm in 2 coats to achieve a total DFT of 1.5mm. It must be applied utilizing plural heated high-pressure spray proportioning machine/spray gun . Termination shall be done 300 mm above FFl by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Lay a 150 GSM geotextile layer to protect the coating from external damage on final coating before laying of screed concrete/final finish. It shall be applied as per manufactures specification. Rates are incl of surface preparation, grouting and chemical application only. (Rates for geotextile, protection plaster and final finishes such as screed or Brick bat filling for slope, china mosaic, tiles etc is not included in above item. It will be added as per EIC/clients requirements).` [Through Rate]
58[30.22]Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. [Through Rate]
59[30.27.1]Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: 1. One or more coats on old work [Through Rate]
60[30.37.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. Old work (Two or more coat applied @ 1.67 litre/ 10 sqm) on existing cement paint surface [Through Rate]
61[30.54.2]Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 2. Float glass panes of nominal thickness 5 mm (weight not less than 12.5 kg/sqm) [Through Rate]
62[30.56.2]Renewing glass panes and refixing existing wooden fillets: 2. Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) [Through Rate]
63[31.9]Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. [Through Rate]
64[34.50]Painting on Steel Surfaces Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade [Through Rate]
65[4.1]Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. [Through Rate]
66[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
67[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate]
68[6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56848275
AUTHORITY Government Departments
TENDER VALUE 5.86 Crore
LAST DATE 27-08-2026
Authority
Authority Name Panchkula Metropolitan Development Authority
Work Description Tender for Operation, Running, Maintenance Of 25Mldttp At Sector-20 Panchkula And 5 Nos. Boosting Stations, Including Repair Spare Parts Etc., Chemical Dosing And Chlorine Gas And Operation And Maintenance Of Distribution Pipe Line Di/Hdpe In Panchkula And Panchkula Extension Complete In All Respect.
Basic Detail
Tender No 2026F19792B4 E30E 45BA B326 F887DE9EDF852264003
Bidding Type Tender
Location
City Panchkula
State Haryana
Key Dates
Publish Date 05 Aug 2026
Submission Date 27 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 5.86 Crore
Tender Fee 20000
EMD 11.74 Lakhs
Exemption Available
Document List
57724f49-633a-4274-8b34-2ecfa1f8ffd4.html
BOQ_617960.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

57724f49-633a-4274-8b34-2ecfa1f8ffd4.html

xls

BOQ_617960.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders