Bids Are invited for Dc Lead Acid Batteries For 2 X 800 Mw Dvc Koderma Tps Phase Ii Project
Tender Overview
Project Description
Bids Are invited for Dc Lead Acid Batteries For 2 X 800 Mw Dvc Koderma Tps Phase Ii Project Battery 1 Area 1, 220V Lead Acid Battery Suitable For Main Plant - A.1.1 , Battery 1- Electrolyte For First Filling Plus 10 Percent Extra In Non-Returnable Container - A.1.2 , Battery 1- Mild Steel Rack With Rubber Mat Coated With Three Coats Of Anti-Acidic Electrostatic Powder Coating Paint - A.1.3 , Battery 1- Stand Insulators Plus 5 Percent Extra - A.1.4 , Battery 1- Intercell, Inter Row, Inter Bank Connectors With Connection Hardware As Required For Complete Installation Plus 5 Percent Extra And End Take-Off With One No. Extra Take Off. - A.1.5 , Battery 1- Cell Numbering Tags With Fixing Arrangement -1Set - A.1.6 , Battery 1- Anti-Splash Type Vent Plug - A.1.7 , Battery 1- Lead Coated Connection Hardware Plus 5 Percent Extra - A.1.8 , Battery 1- Cable Cl S With Fixing Hardware - A.1.9 , Battery 1- Pvc Or Cfrp Spill Trays Under Battery Set -Battery To Have Spill Tray Covering Every Cell - A.1.10 , Battery 1- Battery Trolley - A.1.11 , Hydrometer - A.2.1 , Cell Testing Digital Voltmeter 3-0-3V With Testing Leads - A.2.2 , Wall Mounting Type Holder For Hydrometer And Thermometer - A.2.3 , Set Of Hydrometer Syringes Suitable For Vent Holes In Different Cells - A.2.4 , Thermometer For Measuring Electrolyte Temperature - A.2.5 , Specific Gravity Correction Chart - A.2.6 , Rubber Apron - A.2.7 , Pair Of Rubber Hand Gloves - A.2.8 , Set Of Spanners - A.2.9 , No Smoking Notice - A.2.10 , Goggles Industrial - A.2.11 , Instruction Card - A.2.12 , Minimum And Maximum Temperature Indicator For Each Battery Room - A.2.13 , Acid Or Alkali Mixing Jar - A.2.14 , Cell Lifting Straps - A.2.15 , Battery Health Monitoring System For Each Battey Cell Of Battery Sets As Per Sl.No. A.1.1 Above - A.3.1 , Laptop With Complete Accessories For Bhms - A.3.2 , Ows With Complete Accessories And Wooden Furniture For Bhms - A.3.3 , Battery 2 Area 2- 220V, Lead Acid Battery Suitable For Raw Water Area Located At Raw Water Pmcc Room - A.4.1 , Battery 2- Electrolyte For First Filling Plus 10 Percent Extra - A.4.2 , Battery 2- Mild Steel Rack With Rubber Mat Coated With Three Coats Of Anti-Acidic Electrostatic Powder Coating Paint - A.4.3 , Battery 2- Stand Insulators Plus 5 Percent Extra - A.4.4 , Battery 2- Intercell, Inter Row , Inter Bank Connectors With Connection Hardware As Required For Complete Installation Plus 5 Percent Extra And End Take-Off With One No Extra Take Off - A.4.5 , Battery 2- Cell Numbering Tags With Fixing Arrangement 1Set - A.4.6 , Battery 2- Anti-Splash Type Vent Plug - A.4.7 , Battery 2- Lead Coated Connection Hardware Plus 5 Percent Extra - A.4.8 , Battery 2- Cable Cl S With Fixing Hardware - A.4.9 , Battery 2- Pvc Or Cfrp Spill Trays Under Battery Set- Battery To Have Spill Tray Covering Every Cell - A.4.10 , Battery 2- Battery Trolley - A.4.11 , Hydrometer - A.5.1 , Cell Testing Digital Voltmeter 3-0-3V With Testing Leads - A.5.2 , Wall Mounting Type Holder For Hydrometer And Thermometer - A.5.3 , Set Of Hydrometer Syringes Suitable For Vent Holes In Different Cells - A.5.4 , Thermometer For Measuring Electrolyte Temperature - A.5.5 , Specific Gravity Correction Chart - A.5.6 , Rubber Apron - A.5.7 , Pair Of Rubber Hand Gloves - A.5.8 , Set Of Spanners - A.5.9 , No Smoking Notice - A.5.10 , Goggles Industrial - A.5.11 , Instruction Card - A.5.12 , Minimum And Maximum Temperature Indicator For Each Battery Room - A.5.13 , Acid Or Alkali Mixing Jar - A.5.14 , Cell Lifting Straps - A.5.15 , E And C Spares For Battery 1- Pair Of Rubber Hand Gloves - B.1 , E And C Spares For Battery 1- Vent Plugs - B.2 , E And C Spares For Battery 1- Intercell Connectors - B.3 , E And C Spares For Battery 2- Pair Of Rubber Hand Gloves - B.4 , E And C Spares For Battery 2-Vent Plugs - B.5 , E And C Spares For Battery 2-Intercell Connectors - B.6 , Supervision Of Erection - Battery, For Battery 1 And 2 - C1 , Supervision Of Erection - Battery, For Battery 1 And 2 - C2 , Supervision Of Commissioning - Battery, For Battery 1 And 2 - C3 , Supervision Of Commissioning - Battery, For Battery 1 And 2 - C4 , Supervision Of Commissioning - Bhms, For Battery 1 And 2 - C5 , Supervision Of Commissioning - Bhms, For Battery 1 And 2 - C6 , Mandatory Spares For Battery 1 - Complete Dry Cell - D.1 , Mandatory Spares For Battery 1 - Inter-Cell Connectors With Hardware - D.2 , Mandatory Spares For Battery 2 - Complete Dry Cell - D.3 , Mandatory Spares For Battery 2 - Inter-Cell Connectors With Hardware - D.4
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Aug-2026 | 24-Aug-2026 |
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | BATTERY 1 Area 1, 220V Lead acid battery suitable for MAIN PLANT | A.1.1 |
| 2 | BATTERY 1- Electrolyte for first filling plus 10 percent extra in non-returnable container | A.1.2 |
| 3 | BATTERY 1- Mild Steel rack with rubber mat coated with three coats of anti-acidic electrostatic powder coating paint | A.1.3 |
| 4 | BATTERY 1- Stand insulators plus 5 percent extra | A.1.4 |
| 5 | BATTERY 1- Intercell, inter row, inter bank connectors with connection hardware as required for complete installation plus 5 percent extra and end take-off with one no. extra take off. | A.1.5 |
| 6 | BATTERY 1- Cell numbering tags with fixing arrangement -1set | A.1.6 |
| 7 | BATTERY 1- Anti-splash type vent plug | A.1.7 |
| 8 | BATTERY 1- Lead coated connection hardware plus 5 percent extra | A.1.8 |
| 9 | BATTERY 1- Cable clamps with fixing hardware | A.1.9 |
| 10 | BATTERY 1- PVC or CFRP spill trays under battery set -battery to have spill tray covering every cell | A.1.10 |
| 11 | BATTERY 1- Battery trolley | A.1.11 |
| 12 | Hydrometer | A.2.1 |
| 13 | Cell testing digital voltmeter 3-0-3V with testing leads | A.2.2 |
| 14 | Wall mounting type holder for hydrometer and thermometer | A.2.3 |
| 15 | Set of Hydrometer syringes suitable for vent holes in different cells | A.2.4 |
| 16 | Thermometer for measuring electrolyte temperature | A.2.5 |
| 17 | Specific gravity correction chart | A.2.6 |
| 18 | Rubber apron | A.2.7 |
| 19 | Pair of rubber hand gloves | A.2.8 |
| 20 | Set of Spanners | A.2.9 |
| 21 | No Smoking notice | A.2.10 |
| 22 | Goggles Industrial | A.2.11 |
| 23 | Instruction card | A.2.12 |
| 24 | Minimum and maximum temperature indicator for each battery room | A.2.13 |
| 25 | Acid or Alkali mixing jar | A.2.14 |
| 26 | Cell lifting straps | A.2.15 |
| 27 | Battery Health Monitoring System for each battey cell of battery sets as per Sl.no. A.1.1 above | A.3.1 |
| 28 | LAPTOP with complete accessories for BHMS | A.3.2 |
| 29 | OWS with complete accessories and wooden furniture for BHMS | A.3.3 |
| 30 | BATTERY 2 Area 2- 220V, Lead acid battery suitable for Raw Water Area located at RAW WATER PMCC Room | A.4.1 |
| 31 | BATTERY 2- Electrolyte for first filling plus 10 percent extra | A.4.2 |
| 32 | BATTERY 2- Mild Steel rack with rubber mat coated with three coats of anti-acidic electrostatic powder coating paint | A.4.3 |
| 33 | BATTERY 2- Stand insulators plus 5 percent extra | A.4.4 |
| 34 | BATTERY 2- Intercell, inter row , inter bank connectors with connection hardware as required for complete installation plus 5 percent extra and end take-off with one no extra take off | A.4.5 |
| 35 | BATTERY 2- Cell numbering tags with fixing arrangement 1set | A.4.6 |
| 36 | BATTERY 2- Anti-splash type vent plug | A.4.7 |
| 37 | BATTERY 2- Lead coated connection hardware plus 5 percent extra | A.4.8 |
| 38 | BATTERY 2- Cable clamps with fixing hardware | A.4.9 |
| 39 | BATTERY 2- PVC or CFRP spill trays under battery set- battery to have spill tray covering every cell | A.4.10 |
| 40 | BATTERY 2- Battery trolley | A.4.11 |
| 41 | Hydrometer | A.5.1 |
| 42 | Cell testing digital voltmeter 3-0-3V with testing leads | A.5.2 |
| 43 | Wall mounting type holder for hydrometer and thermometer | A.5.3 |
| 44 | Set of Hydrometer syringes suitable for vent holes in different cells | A.5.4 |
| 45 | Thermometer for measuring electrolyte temperature | A.5.5 |
| 46 | Specific gravity correction chart | A.5.6 |
| 47 | Rubber apron | A.5.7 |
| 48 | Pair of rubber hand gloves | A.5.8 |
| 49 | Set of Spanners | A.5.9 |
| 50 | No Smoking notice | A.5.10 |
| 51 | Goggles Industrial | A.5.11 |
| 52 | Instruction card | A.5.12 |
| 53 | Minimum and maximum temperature indicator for each battery room | A.5.13 |
| 54 | Acid or Alkali mixing jar | A.5.14 |
| 55 | Cell lifting straps | A.5.15 |
| 56 | E and C SPARES For Battery 1- Pair of rubber hand gloves | B.1 |
| 57 | E and C SPARES For Battery 1- Vent Plugs | B.2 |
| 58 | E and C SPARES For Battery 1- Intercell connectors | B.3 |
| 59 | E and C SPARES For Battery 2- Pair of rubber hand gloves | B.4 |
| 60 | E and C SPARES For Battery 2-Vent Plugs | B.5 |
| 61 | E and C SPARES For Battery 2-Intercell connectors | B.6 |
| 62 | SUPERVISION OF ERECTION - BATTERY, For Battery 1 and 2 | C1 |
| 63 | SUPERVISION OF ERECTION - BATTERY, For Battery 1 and 2 | C2 |
| 64 | SUPERVISION OF COMMISSIONING - BATTERY, For Battery 1 and 2 | C3 |
| 65 | SUPERVISION OF COMMISSIONING - BATTERY, For Battery 1 and 2 | C4 |
| 66 | SUPERVISION OF COMMISSIONING - BHMS, For Battery 1 and 2 | C5 |
| 67 | SUPERVISION OF COMMISSIONING - BHMS, For Battery 1 and 2 | C6 |
| 68 | MANDATORY SPARES For Battery 1 - Complete dry cell | D.1 |
| 69 | MANDATORY SPARES For Battery 1 - Inter-cell connectors with Hardware | D.2 |
| 70 | MANDATORY SPARES For Battery 2 - Complete dry cell | D.3 |
| 71 | MANDATORY SPARES For Battery 2 - Inter-cell connectors with Hardware | D.4 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender