Tender For Repair To Roofing, Plastering, False Ceiling, Wall Panelling And Allied Works In Various Certain Buildings At Air Force Station Highground Under Age (I) Highground Chandigarh
Tender Value
8 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
12 days left
EMD
16000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Roofing, Plastering, False Ceiling, Wall Panelling And Allied Works In Various Certain Buildings At Air Force Station Highground Under Age (I) Highground Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Dismantaling brick tiles or terracing tiles single layer in roof complete all as specified and directed. |
| 2 | Demolition of mud phuska on roofs any thickness including mud plastering (whether full thickness removed or only a part thereof) and removal to a distance exceeding 100 metre, complete all as specified and directed. |
| 3 | Material and Labour for Plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in roof padding and maintaining required slope incl mixing water proofing compound (Dr. Fixit or equivivalent) as per manufacturers instruction (water proofing liquid shall be paid seperately) complete all as specified and as directed. |
| 4 | Taking down existing water proofing treatment and chiselling the existing bituminou coating and rubbish off the premises to a distance exeeding 150 metre but not exceeding 250 metre out of MoD land complete all as specified and directed. |
| 5 | Material and Labour for providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflective Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete applications/system not less than 500 microns). The operation shall be carried out after scraping and properly cleaning the surface to remove loose particles with wire brushes complete in all respects, the work shall be carried out on both horizontal and vertical surfaces complete all as specified and directed. Also the work shall be carried out by authorised applicator only. |
| 6 | Material and Labour for PCC 1:2:4 type B1 as in roof kerb or mud stops mixed with water proofing compound @ 1% by wt of cement including all necessary form work complete all as specified and directed. |
| 7 | Supply only liquid water proofing compound complete all specified and directed.Make: Pidiproof WL (Dr Fixit) or equivalent ISI marked make as approved by GE. |
| 8 | Supply and Fix in repair Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve, complete all as specified and directed. |
| 9 | Supply and Fix in repair Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve, complete all as specified and directed. |
| 10 | Supply and Fix in repair Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 210 gms), screwed & suitable for iron pipe 20 mm bore, complete all as specified and directed. |
| 11 | Supply and fix in repair 20mm Gun metal,globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 12 | Demolition of brick work built in cement mortar including all quoins arches pillars complete all as specified and directed. |
| 13 | Material & Labour for brick work sub class “B” bricks straight or curved in plan exceeding 6 metre mean radius with old size bricks Iin Cement Mortar 1:6 complete all as specified and directed. |
| 14 | All as per item No 13 above but except bricks complete all as specified and directed. |
| 15 | Taking down cement plaster including racking out joints hacking for key scrubbing down with water complete all as specified and directed. |
| 16 | Material and Labour for rendering 15mm thick in cement mortar 1:4 as on brick walls finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 17 | Material and Labour for 10 mm thick rendering in CM 1:3 on concrete surface on ceiling (such as chajjas, beams, roof projections, balcony, mumty and stair case flight ceiling, roof slab etc) finished even and fair without using extra cement, complete all as specified and directed.Note:- The rate quoted by contractor is deemed to be inclusive of necessary scaffolding and form work upto 12 metres height or G+2 storey building. |
| 18 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories. |
| 19 | Supply and Fix PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, 110mm double socketed complete all as specified and directed. |
| 20 | Supply and Fix PVC (SWR) bend 110 mm complete all as specified and directed. |
| 21 | Taking up or down steel water tubing and connection including cleaning for refixing or removal to stone of 15mm bore complete all as specified and directed. |
| 22 | Taking up or down steel water tubing and connection including cleaning for refixing or removal to stone of 20mm bore complete all as specified and directed. |
| 23 | Material & Labour for GI tubing 15mm bore fixed to walls, ceilings or laid in floors medium grade complete all as specified and directed. |
| 24 | Refixing GI tubing 15mm bore fixed to walls, ceilings or laid in floors medium grade tube complete all as specified and directed. |
| 25 | Material & Labour for GI tubing 20mm bore fixed to walls, ceilings or laid in floors medium grade complete all as specified and directed. |
| 26 | Refixing GI tubing 20mm bore fixed to walls, ceilings or laid in floors medium grade tube complete all as specified and directed. |
| 27 | Dismantling plain or corrugated steel/PVC/fiber/asbestos sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed. |
| 28 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. |
| 29 | Supply and Fix Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410 complete all as specified and directed. |
| 30 | Material and Labour for Prepration of new steel Surfaces of any description, over 10cm in width or girth and applying two coat of synthetic emamle paint over one coat of red oxide primer complete all as specified and directed. |
| 31 | Material and Labour for Prepration of old painted steel surface of any description over 10cm in width or girth not otherwise specified and applying two coats of synthic enamel paint complete all as specified and directed. |
| 32 | Material & Labour for Fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 33 | Supply and Fix Pre- painted galvalume aluminum zinc coating (AZ 150) GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 34 | Supply and Fix Pre- painted galvalume aluminum zinc coating (AZ 150) GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 35 | Material & Labour for 10 mm thick rendering in cement 1:4 on faces of concrete surface over and including 10 mm thick dubbing on wall/ concrete surfaces (edges of chajjas, roof, roof projectios and similar items) in two layers with finished surface even and smooth w/o using extra cement with and incl taking down broken surfaces of concrete complete all as specified and directed. |
| 36 | Material & Labour for preparation of new plastered or un-plastered surfaces of walls, cornices etc such as brooming down or steel wire brushing, scraping down smoke shoots, moulds, moss and efflorescent salt and trading oil and greasy spots and applying two coat of cement base pain over a coat of primer complete all as specified and directed. |
| 37 | Dismantling wall and ceiling boards (fibre pulm, insulation etc )or insulation board/slabs/blanket, any thickness/type with or without frame including repairing/treating the damages surface of wall and ceiling as per existing surface complete all as specified and as directed. |
| 38 | Supply & Fix False ceiling board at all heights of 600 mm x 600 mm x16 mm mineral fibre ceiling tiles of type classic lite RH-99 fine texture of 'Amstrong' (or equivalent of make as mentioned in Appx 'A' list of makes) laid on existing exposed grid system after levelling, re-alining etc complete all as specified and directed. |
| 39 | Supply and Fix 6 mm thick, Pre-painted, False ceiling tile ( Density > 1200 Kg/m3 , Modulus of Rupture(M.O.R) - 15.85Mpa, Thermal Conductivity (K)- 0.0872 W/mK,Confirming to IS 14862 ; Type- B Category-III) of size 595x595mm (for grid module of size 600x600mm) with modular Lay-In-Grid ceiling system, con which includes fixing of E-grid framework comprising of pre coated wall angle of size 24x24x3000mm and 0.35mm thick screw fixed to periphery of the walls / partitions at the required ceiling height with PVC dash fastners (nylon sleeves) and steel screws at 600mm c/c . GI main Tee runners with pre coated steel capping of size 24x38x3600/3000mm and 0.25mm thick shall then be suspended from the soffit (or purlins) with 4mm dia hanger GI wire, soffit cleat of size 27x37x25x1.6mm and dia 6x40mm Metal anchor fastners at 1200 mm c/c ( in case of purlin, the 6mm GI suspender wire shall be wrapped around it ). Cross Tee of size 24x26x1200mm and 0.25mm thick are then insert fixed into the main Tee runner @ 600mm centres and in direction perpendicular to it , for 600x1200mm module grid, Finally for the required 600x600mm grid module 600mm Cross Tee of size 24x26x600mm and 0.25mm thick shall be insert fixed into the 1200mm Cross Tee @ 600mm centres and in direction perpendicular to it, complete all as specified and directed.Note :- (i) Existing ceiling lights, ceiling fan and other items required to be refix again after fixing of false ceiling.(ii) Damaged portion of wall/ceiling during dismantling and refixing of ceiling required tobe repair with similar treatment.Make : Armstrong/Everest or equivalent. |
| 40 | Supply and Fix PVC wall panelling with hollow profile 5 mm thick of panel size 160mm x 2900mm with teak or similar colour finish with screw / nails / Clips including top/bottom U cover channels and edge angle beading of similar shade complete all as specified and directed. |
| 41 | Material and Labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 42 | Material and Labour for cutting out cracks to effected portion mechinically, of minimum width 5 mm and depth equal to width in existing RCC roof, parapet or terracing cleaning out and applying PU sealent of approved make complete all as specified and directed. Make : Dr fixit or equivalent from list of makes |
| 43 | Supply and Fix PVC wall panelling with hollow profile 8.0 mm thick of panel size 450mm x 2900mm with teak or similar colour finish with screw / nails / Clips including top/bottom U cover channels and edge angle beading of similar shade complete all as specified and directed. |
| 44 | Note: The total amount shall subject to adjustment of credit of Rs 19260.00 for old Materials as per Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender