Tender For Repairing, Renovation Of All The Rooms And 40 (Forty) Bath-Rooms At Unit-I And 12 (Twelve) Duct Lines At Unit-Ii & Iii Of Mla Hostel, 2, Kyd Street, Kol - 700016...Related electrical installation Work.
Tender Value
35.84 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
12 days left
EMD
71698
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing, Renovation Of All The Rooms And 40 (Forty) Bath-Rooms At Unit-I And 12 (Twelve) Duct Lines At Unit-Ii & Iii Of Mla Hostel, 2, Kyd Street, Kol - 700016...Related electrical installation Work.
BOQ
| Sl. No. | Item Description |
| 1 | Cost of labour charges for dismantling the existing E.I & mending goods the damages.(15 Nos. semi-skilled & 15 Nos. un-skilled labour) |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. (GROUP-C) |
| 3 | Supplying and fixing two module stepped typeelectronic fan regulator on the existing modular plateswitch box including connections but excludingmodular plate etc. as required. |
| 4 | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 5 | a)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 6 | b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 7 | c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | LED Batten light (System lumen efficacy >135lm/Watt) Supplying, installation, Testing & Commissioning ofLED surface mounted Batten light of following bodymaterial and construction as per IS : 10322 withdriver (Replaceable) as per the requirement withDriver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard DeviationColor Matching) <3, Maximum power consumptionshould not more than the specified rating andFixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete inall respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumenefficacy >135 lm/Watt output . LM79 & LM80 Testreport and all testing required for LED fixturesas per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge asper requirement. (Thermal management: heat sinkof aluminium housing such that LED junctiontemperature shall not rise above 90°C). |
| 10 | Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)18- 22 Watt |
| 11 | Sapply & Fixing 240 V 30 A, 2 or 3 Modular type Key Card energy seving device with indicator & necessary cunnaction like wire screws nut sockting etc (Make-Honeywell/Crabtree) |
| 12 | Supply and Fixing of Auxiliary Contact 240V , 50 Hz. , 32A, MNK-22, (Make- L&T) |
| 13 | Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularswitches in recess etc. as required. |
| 14 | 1 or 2 Module (75mmX75mm) |
| 15 | 3 Module (100mmX75mm) |
| 16 | 6 Module (200mmX75mm) |
| 17 | 8 Module (125mmX125mm) |
| 18 | 12 Module (200mmX150mm) |
| 19 | Supplying and fixing following modular switch/ socketon the existing modular plate & switch box includingconnections but excluding modular plate etc. asrequired. |
| 20 | Bell push |
| 21 | 6 pin 15/16 A socket outlet |
| 22 | 15/16 A switch |
| 23 | 3 pin 5/6 A socket outlet |
| 24 | 5/6 A switch |
| 25 | Supplying and fixing call bell/ buzzer suitable forsingle phase, 230 V, complete as required. |
| 26 | Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modularsocket outlet and 5/6 A modular switch, connectionsetc. as required. |
| 27 | Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch,connections etc. as required. |
| 28 | Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired. (20 mm Dia) |
| 29 | Extra for suspension exceeding 25cm with s & f additional 2 no. 20mm dia conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as reqd. by 2 x 24/ 0.20 mm (1.5 sqmm) flexible copper wire of 1.10mt. Length |
| 30 | Supply & Fixing 240V, 65W, having RPM-320, 1200 mm Sweep (1) one star, 3nos. Blades , AC Celing Fan, including Supply & Fixing Related all accessories as per Maintained by PWD Norms. (Make: Orient / Usha/Crompton / Havells) |
| 31 | S & F of 240V, 6 Watt Single head Decorative type Wall Night light. Including with nacessary connection like wire, nut, socket, screws etc. (Make:-Direction by EIC. ) |
| 32 | Supply & Fixing Decorative type 12W, 1ft Long LED Mirror/Basin Wall Light as direction of EIC. Including with nacessary connection like wire, nut, socket, screws etc. (Make - Philips Photon Mirror (Make:-Direction by EIC. ) |
| 33 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – ((Make:-Direction by EIC. ) |
| 34 | Supply & Fixing 240 V, 25 A, Modular type starter (Make-North West) with 25A Modular switch type DP MCB (C Curve) and 4 Module Gl Modular type switch board with 4 Modale top cover plate flushed in wall incl, S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 35 | Supply & Fixing 240 V, 25 A 3 pin Modular type plug socket (Make -North West/Crabtree/standard), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 36 | Sapply & Fixing 240 V 25 A, 3 pin Modular type plug top with indicator (Make--North West/Crabtree/standard/Anchor)) & necy. Connections. |
| 37 | Supply & Fixing 12\\" (230 mm) sweep 1470 RPM exhaust fan(Make-EPC,heavy duty) after making hole in wall and mending good damages and smooth cement finish etc. as practicable as possible and providing necy. Length of PVC insulated copper wire including supply and fixing louver shutter on wall with necy. bolts &nuts (6 mm dia x 62 mm long) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender