Tender For The Supply And Installation Of Air-Conditioning Units In The Courtrooms And Retiring Rooms Of The District Judge And Additional District Judge Under The Auraiya District Court.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Aug 2026
7 days left
EMD
2.34 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Auraiya → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For The Supply And Installation Of Air-Conditioning Units In The Courtrooms And Retiring Rooms Of The District Judge And Additional District Judge Under The Auraiya District Court.
BOQ
| Sl. No. | Item Description |
| 1 | PART-A SITC of Air Cooled Hi wall split type AC Complete with Indoor unit, Outdoor unit, Conceled copper refrigrnt piping with insultaion invertor type-cooling only 2.0 TR 5 Star BEE Rating The System shall be able to operate up to 52 C (Outdoor ambient temprature) Make-Carrier, Blue Star, LG, Panasonic |
| 2 | SITC of Air Cooled Hi wall split type AC Complete with Indoor unit, Outdoor unit, Conceled copper refrigrnt piping with insultaion invertor type-cooling only 1.5 TR 5 Star BEE Rating The System shall be able to operate up to 52 C (Outdoor ambient temprature) Make-Carrier, Blue Star, LG, Panasonic |
| 3 | SITC of 4 KVA Automatic Voltage stablizer (130-280V) Copper winding. |
| 4 | SITC of 5 KVA Automatic Voltage stablizer (130-280V) Copper winding. |
| 5 | Supply and laying of 2.5 Sq. mm. 4 Core round copper cable for indoor unit to outdoor unit. |
| 6 | Supply and laying of 2.5 Sq. mm. 3 Core round copper cable for stablizer to indoor unit. |
| 7 | SITC of suction/discharge pipe line in split A.C. unit up to 1.5 ton capacity including brazing, nitrile, rubber insulation 6 mm thick class 'O' etc. complete 1/4\\" (6.40 mm.) and 1/2\\" (12.70 mm) |
| 8 | SITC of suction/discharge pipe line in split A.C. unit up to 1.8/2.0 ton capacity including 8 brazing, nitrile, rubber insulation 9 mm thick class 'O' etc. complete 3/8\\" (9.50 mm.) and 5/8\\" (15.90 mm) |
| 9 | Supply and laying of heavy duty PVC plastic draided 20 mm. OD flexible pipe for condensed water with clipping accessories complete. |
| 10 | Supply and fixing of Outdoor unit stand for split type A.C. |
| 11 | Supply, Fabrication and Installation of M.S. cage for protection of outdoor unit from animal/theft LXWXH 1300 mm X 600 mm X 1200 mm complete in all respect |
| 12 | PART-BWiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required Upto 120 sq. mm |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 15 | Earthing with G. I. earth pipe 4. 5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 16 | Supplying and laying 25 mm X 5 mm G. I strip at 0. 50 metre below ground as strip earth electrode, including connection/ terminating with G. I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G. I. nut bolt & spring washer spaced at 50mm) |
| 17 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 18 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1. 1 KV grade as required. 3½ X 25 sq. mm (28mm) |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1. 1 KV grade as required. 3 X 185 sq. mm (57mm) |
| 20 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sq. mm. 3.5 Core |
| 21 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 185 Sq. mm. 3.5 Core |
| 22 | Supply & Installation, testing and commisioning of LT Panel vermin proof floor mounting, M.S. channel base with bottom and fabricated out of 2.0/1.6 mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer-In-Charge after proper sheet treatment process of conductive Aluminium alloy of appropriate cross section as per rating. The main incomer rating. The Bus Bar shall be supported by non hygrosopic SMC/DMC Bus bar supports which shall be mounted on proper internal to ensure the bear the jerks of shorts circuit of 50 KA for panel having ACB as Incomer & 36 kA for panel having MCCB Incommer PAnel shall be constructed in fully segregated compatment Design for Each feeder as per 3b construction format. The Panel Shall be complete in all respect as per IS: 8623 Part-2&3 There shall be separte Metering compartmenr for incomer metering and outgoing metening along with phase Indicating Lights and other associated compoments such as CT Control MCB Terminal Block etc. The Feeder above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicated Lights shall be LED type wiring shall be done form 1100 V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Relese of Breaking / Withstand capacity (ICU/ICS) 36 kA or more All MCB Shall be Thermal 10 kA 'C' Curve Cubicle type switch board shall be Cat-A an B only.Incoming:- 200 Amp. / 415 Volt MCCB- 01 No,Outgoing-63 Amp. MCCB-05 Nos. |
| 23 | Supply and Fixing of 63 Amp. FP MCB (10 kA) 240 V/415 V, 50 Hz, Leygrand or Eq. |
| 24 | Total Cost Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender