Tender For Repairs / Maint/ Servicing Of Internal Wiring, Light Fittings And Connected Accessories At C And E Area Under Ge Chennai
Tender Overview
Project Description
Tender for Repairs / Maint/ Servicing Of Internal Wiring, Light Fittings And Connected Accessories At C And E Area Under Ge Chennai
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Aug-2026 | other_corrigendum | Other | 26-Aug-2026 |
| 2 | 13-Aug-2026 | BOQ_corrigendum | BOQ | 26-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for point wiring of size 1.5 sqmm with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through new non metallic rigid PVC conduit including accessories, concealed in wall/floor and fixed on ceiling/roof etc, including provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly including taking down old copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses, regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and directed for the following;- (a) one light point controlled by one switch |
| 2 | one fan point controlled by one switch |
| 3 | one 3 pin socket outlet 5 amps on the same board controlled by one switch. |
| 4 | one 3 pin socket outlet 5 amps on independent board controlled by one switch. |
| 5 | one light point controlled by two switch of 2 Way |
| 6 | one bell/buzzer point controlled by one bell push |
| 7 | As per above items No. 1 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed. |
| 8 | M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through non metallic rigid Existing PVC conduit , in wall/floor and fixed on ceiling/roof etc, including provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly including taking down old copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses, regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and directed for the following;- |
| 9 | one light point controlled by one switch |
| 10 | one fan point controlled by one switch |
| 11 | one bell/buzzer point controlled by one bell push |
| 12 | one 3 pin socket outlet 5 amps on the same board controlled by one switch. |
| 13 | one 3 pin socket outlet 5 amps on independent board controlled by one switch. |
| 14 | one light point controlled by two switch of 2 Way |
| 15 | As per above items No 3 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed. |
| 16 | M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cabel of 1100V grade drawn through non metallic rigid surface PVC conduit , in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete all as specified and directed. |
| 17 | one light point controlled by one switch |
| 18 | one fan point controlled by one switch |
| 19 | one bell/buzzer point controlled by one bell push |
| 20 | one 3 pin socket outlet 5 amps on the same board controlled by one switch. |
| 21 | one 3 pin socket outlet 5 amps on independent board controlled by one switch. |
| 22 | one light point controlled by two switch of 2 Way |
| 23 | As per above items No 5 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed. |
| 24 | M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cabel of 1100V grade drawn through new non metallic rigid PVC casing capping including accessories, casing caping in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete all as specified and directed |
| 25 | one light point controlled by one switch |
| 26 | one fan point controlled by one switch |
| 27 | one 3 pin socket outlet 5 amps on the same board controlled by one switch. |
| 28 | one 3 pin socket outlet 5 amps on independent board controlled by one switch. |
| 29 | one bell/buzzer point controlled by one bell push |
| 30 | As per above items No 7 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size (Two run) & 1.5 Sqmm (One run) complete all as specified and directed. |
| 31 | S& F for modular metal flush box 2 module complete all as specified and directed. |
| 32 | S& F for modular metal flush box 4 module complete all as specified and directed. |
| 33 | S& F for modular metal flush box 6 module complete all as specified and directed. |
| 34 | S& F for modular cover plate with frame 2 module complete all as specified and directed. |
| 35 | S& F for modular cover plate with frame 4 module complete all as specified and directed. |
| 36 | S& F for modular cover plate with frame 6 module complete all as specified and directed. |
| 37 | S&F modular switches suitable for type AC 240V, 6 amps 1 module complete all as specified and directed. |
| 38 | S&F modular sockets suitable for type AC 240V, 6 amps 2 module complete all as specified and directed. |
| 39 | S&F modular switches two way suitable for type AC 240V, 6 amps 1 module complete all as specified and directed |
| 40 | S&F modular switches suitable for type AC 240V, 16 amps 1 module complete all as specified and directed. |
| 41 | S&F modular power sockets suitable for type AC 240V, 16 amps 2 module complete all as specified and directed. |
| 42 | S&F modular fan regulator step type suitable for type AC 240V, 2 module complete all as specified and directed. |
| 43 | S&F modular bell push / switch suitable for type AC 240V, 16 amps complete all as specified and directed by Engr-in-Charge |
| 44 | S&F call bell of multi music type A/C 230 volts complete all as specified and directed. |
| 45 | S&F ceiling rose , polycarbonate, isolated body with 2 to 3 terminals complete all as specified and directed. |
| 46 | S&F lamp holder insulated body with PVC / Polycarbonate with back plate for batten fittings/angle holder complete all as specified and as directed. |
| 47 | S&F of LED bulb 9 w high suitable for lamp holder complete all as specified and as directed. |
| 48 | S & F 20 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminium housing with wide range of wattages to suit variety of application areas, including taking down unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed. Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or its techno commercial equivalent in Philips/Bajaj or from any one of the makes listed in PS List of makes. |
| 49 | S & F 10 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminium housing with wide range of wattages to suit variety of application areas, including taking down unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed.Make : Havells Cat No. LUMILINEPLUSBS10WLED865SPCSSIND or its techno commercial equivalent in Philips/Bajaj or from any one of the makes listed in PS List of makes. |
| 50 | S & F 36 Watts 2x2 ceiling COOL LIGHT a versatile 2X2 recess mounted luminaries which suits various ceiling types with option to add mounting kits for POP ceiling & suspension clamp for pendant mounting from true ceiling, including taking down unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed. Make Havells Cat No. VENUSNEO2X2PLR36WLED865G2 or its techno commercial equivalent in Philips/Bajaj or from any one of the makes listed in PS List of makes. |
| 51 | S&F in repairs of switch piano flush type 5 amps single pole one way including taking down unserviceable complete all as specified. |
| 52 | S&F in repairs of switch piano flush type 6 amps single pole two way including taking down unserviceable complete all as specified. |
| 53 | S&F in repairs modular switches suitable for type AC 240V, 6 amps 1 module including taking down the old unserviceable complete all as specified and directed |
| 54 | S&F in repairs modular sockets suitable for type AC 240V, 6 amps, 2 module including taking down the old unserviceable complete all as specified and directed |
| 55 | S&F in repairs of socket outlet 2 in 1, 3pin 5 amps 230 volts including taking down unservicable complete all as specified and directed by Engr-in Charge |
| 56 | S&F in repairs modular switches suitable for type AC 240V, 16 amps 1 module including taking down the old unserviceable complete all as specified and directed |
| 57 | S&F in repairs modular power sockets suitable for type AC 240V, 6/16 amps, 2 module including taking down the old unserviceable complete all as specified and directed |
| 58 | S&F in repairs of switch piano flush type 15 amps single pole one way including taking down unserviceable complete all as specified. |
| 59 | S&F in repairs of socket outlet 3 pin, 15 Amp, flush type including taking down unservicable omplete all as specified and directed by Engr-in Charge |
| 60 | S&F in repairs of bell push 5 amps 230 volts flush type including taking down unservicable complete all as specified and directed by Engr-in Charge |
| 61 | S&F in repairs of Electronic fan regulator dimmer type,450w , 250 volt including taking down unservicable complete all as specified and directed by Engr-in Charge |
| 62 | S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor including taking down complete all as specified and directed.all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length. |
| 63 | Taking down AC box any type and any size complete after taking proper disconnecting of electric supply properly and making good surface complete all as specified and directed |
| 64 | S&F MCB Power unit with 4 module steel box consisting of 3 pin 24 Amps socket with Plug top and MCB SP 25 Amps, suitable for operation of AC & Geysers etc., complete all as specified and as directed. |
| 65 | Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4 mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected up to switch board including 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including earth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete including taking down complete all as specified including testing on completion. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender