Tender For Comprehensive Repair To Roof, Removal Of Grass, Bushes, Cleaning Of Water Tank, Repair To Parapet Haunching/ Bunching Etc Under Ge (West) Jrc
Tender Value
35 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
17 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Repair To Roof, Removal Of Grass, Bushes, Cleaning Of Water Tank, Repair To Parapet Haunching/ Bunching Etc Under Ge (West) Jrc
BOQ
| Sl. No. | Item Description |
| 1 | M & L for uprooting of trees, grass, bushes etc from brick wall/roof surface/or any other surfaces of building incl dismantling the req brick work/roof tiles/mud concrete etc for uprooting the vegetation etc and make good the same to match with existing surface with same material or concrete (1:2:4) type B-1 after pouring the chemical (which destroy the growth of vegetation to the place where vegetation removed). The rate shall include for scaffolding or any other arrangement required during this process upto 10 mtr height complete all as specified and directed. |
| 2 | Demolition of brick work built in cement mortar including all quoins, arches, pillar etc, but excluding ashlar facings complete all as specified and directed. |
| 3 | Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:6 complete all as specified and directed. |
| 4 | M&L brickwork with subclass `B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except bricks complete all as specified and directed. |
| 5 | M&L 40mm thick brick tiles laid in cement mortar bed 1:6 , 15 mm thick and joints grouted flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement complete all as specified and directed. |
| 6 | All as per ser item No 5.00 above but except tiles complete all as specified and directed. |
| 7 | M&L Flush pointing in cement mortar 1:3 on brick tiles laid flat complete all as specified and directed. |
| 8 | Demolition of cement concrete above ground floor and paving exc 15 cm thick (below or above ground level complete all as specified and directed. |
| 9 | M&L for PCC 1:2:4 type B-1(using 20mm graded stone aggregates) in roof kerbs or mud stops benching rounded or chamfered on edges complete all as specified and directed. |
| 10 | Taking down cement plastering on stone wall/brick wall etc including racking out of joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 11 | M&L 15mm thick rendering with water proofing liquid as per manufacturer instruction of approved make : Like : Sica/Dr Fixit/Fosroc on wall in CM 1:4 on brick/concrete surface and finishing the surface even and smooth with out using extra cement complete all as specified and directed. |
| 12 | Cleaning of over head tank of any description and any capacity descaling, washing complete with soap solution and removing vegetation around the over head tank/plate form including opening and reconnecting with GI tubing as site requirement complete all as specified and directed.(Note: Date of cleaning to be written on the tank after cleaning) |
| 13 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 14 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 15 | S&F in repairs 110 mm bore PVC (SWR) bends with access door of any radius, complete all as specified and directed. |
| 16 | S&F in repairs 110 mm bore PVC (SWR) junction single (Single T) with access door equal or unequal, complete all as specified and directed. |
| 17 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 18 | S&F in repairs 75 mm bore PVC (SWR) bends with access door any radius, complete all as specified and directed. |
| 19 | S&F in repairs 75 mm bore PVC (SWR) junction single (Single T) with access door equal or unequal, complete all as specified and directed. |
| 20 | S&F in repairs 75 mm bore PVC (SWR) junction double (double T) with access door equal or unequal, complete all as specified and directed. |
| 21 | S & F for PVC 110mm (SWR) vent cowl complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender