Tender For repair maintenance Of Various E And M Services Installed At Lbs Hospital, Khichripur, Delhi.(Sh: (1). Supplying And Replacement Of Faulty Items And Upgradation Of Existing Cctv System Installed At Various Locations In Lbs Hospital. (2). On
Tender Overview
Project Description
Tender for repair maintenance Of Various E And M Services Installed At Lbs Hospital, Khichripur, Delhi.(Sh: (1). Supplying And Replacement Of Faulty Items And Upgradation Of Existing Cctv System Installed At Various Locations In Lbs Hospital. (2). One Time Repair Of Existing Water Coolers With Inbuilt Ro+Uv System And Dispensers With Inbuilt Ro+Uv System Installed In Lbs. (3). Supplying And Replacement Of electrical installation Led Fixture And Wtac/Stac As And When Required At Ayam Under Jurisdiction Of Ae (E), Lbsh).
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Aug-2026 | Other | Other | 12-Aug-2026 |
| 2 | 12-Aug-2026 | date extended | Date | 17-Aug-2026 |
| 3 | 07-Aug-2026 | Other | Other | 17-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | 1. SH: Supplying and replacement of faulty items and upgradation of existing CCTV System installed at various locations in LBS Hospital: upplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser,Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHSa) 4MP @ 25/30fps@1440P (2560x1440) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. |
| 2 | Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser,8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHSa) 4MP @ 25/30fps@1440P (2560x1440) Outdoor Bullet Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. |
| 3 | Supply, installation, testing & commissioning of 4MP IP ANPR Camera :1/1.8\\"\\" 4 MP CMOS sensor , Max. 4MP (2688 × 1520)@30fps,H.265, H.264M, H.264H, H.264B, MJPEG,10 mm–40 mm Motorized Lens• ANPR capability should be available , WDR(120dB) or better, Day/Night(ICR), 3D NR, BLC, HLC. IR Range of 20 Mtr. or better , IP67, IK10• Alarm Inputs / outputs: 1 input & 1 output or more should be available Audio Inputs / outputs: 1 input & 1 output should be available ANPR Feature: Recognize license plate numbers and letters , Vehicle head: Large bus, heavy truck, medium truck, sedan, van, light truck, medium bus, SUV, large bus, Vehicle Color, Vehicle Logo Traffic Flow Detection: Statistics on vehicle flow, average speed, vehicle type, lane occupancy, average time headway, average queue length, and road status.ONVIF Profile ‘S’ ‘T’ & ‘G’ CE,FCC,ROHS,ONVIF,BIS and Cyber security certificate from STQC:- OWASP application verification standard v4.0- Appendix C: Internet of Things verification requirement L2. CCTV OEM should have ISO9001:2015, ISO 14001:2015, ISO 27001:2013 , ISO 45001:2018 & GDPR Certificate. |
| 4 | Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :-PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- 1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS3)Signal System: PAL/NTSC4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,, 0 lux with IR, or better5) Imaging: 1/1s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Event Notification: Through Relays, E-Mails or FTP9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance. The camera should have IR LED’s and cover distance up to 150 meter or above.10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it.11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering.12) Presets: 300 Presets13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72314) Wide Dynamic Range: WDR (120dB or more), HLC & BLC15) Digital Noise Reduction: DNR (2D+3D) On/Off16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser17) Profile Management: User configuration import, export18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution.19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be supplied with minimum 128GB Memory.20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, Face Detection22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS.23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).24) VMS: Camera shall support open source VMS25) Connectivity: 1x LAN RJ-45 (10/100Base-T)26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.127) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at)30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection31) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS2 MP IP IR motorized PTZ @ 25/30fps or better camera, Triple streaming , configurable on resolution Main stream: 1080p@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.3-137 mm or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digital zoom with angle of view 57˚–2.4˚ , PAN Travel: Pan: 0° ~ 360° endless, Manual Pan: 260° /s, Preset : 300° /s, Tilt, Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s |
| 5 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.a)10TB (Terabytes) |
| 6 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports withnon-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 ormore MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x,ARP Spoofing, DHCP Snooping and server screening,IP+MAC+Port Binding, Per Port Bandwidth Control,802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP,TLS, TTLS, PEAP Support) Cable Diagnostic feature,LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c,v3 and SNMP Traps. Certifications: UL, CE, FCC,RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication,Government of India etc. complete as required. |
| 7 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.a) 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min.(a) 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 8 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U Rack, IP55, Front Door |
| 9 | 9U Rack, IP55, Front Door |
| 10 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required.a) 1 Run of cable |
| 11 | Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.a) 1G SFP Single Mode/Multi Mode |
| 12 | Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a) 25 mm |
| 14 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.a) 42 inch or larger |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 16 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 17 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbpsincoming Bandwidth.2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10.6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic.11) 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive anycombination of critical, warning, or informational messages or alarm notifications. When an alarmoccurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm.24) It should have Web and GUI interface.25) Built-In Artificial Intelligence: NVR should have built-in AI :-- 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection.26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image.27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan,cybersecurity exception30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency.33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics34) Analytics by NVR: Perimeter protection and face recognationa) 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 |
| 18 | Supplying and fixing of PVC Gang Box of suitable size for existing camera isntallation etc. as reqd. at site. |
| 19 | Dismantling of following wornout materials from existing position and credit under buy back : Dome Cameras / Bullet Cameras |
| 20 | PTZ Cameras |
| 21 | PoE Switches (8/16 Port) |
| 22 | Rack (6 U/9U) |
| 23 | LED/LCD Display (42 Inches or Higher) |
| 24 | NVR 64 Channel |
| 25 | Cat 6 Wire |
| 26 | (B)One time Repair of Existing Water coolers with inbuilt RO+UV system and Dispensers with inbuilt RO+UV system installed in LBS One time repair and service of Existing RO Water Purification system installed at various sites i/c Supply, Replacement & ITC of following items etc. complete as required at site i/c buyback of old dismantled material by the contractor.Supplying , replacement , testing and commissioning of RO TFC Cartridge 4021 GPD etc complete as reqd at site i/c buyback of old dismantled material. |
| 27 | Supplying , replacement , testing and commissioning of RO TFC Cartridge 1812GPD etc complete as reqd at site i/c buyback of old dismantled material. |
| 28 | Supplying and Charging of Refrigerant Gas R-134 in the existing Water Coolers after pressure testing, leak detection and rectifying the breakage (if any) etc. complete as required at site. |
| 29 | Supplying and Charging of Refrigerant Gas R-134 in the existing Water Dispenser after pressure testing, leak detection and rectifying the breakage (if any) etc. complete as required at site. |
| 30 | Supply, Replacement & ITC of Pre Filter Assembly of size 20\\" to control excess silt in feed water to RO machines i/c Leak testing etc. complete as required at site i/c buyback of old dismantled material. |
| 31 | Supply, Replacement & ITC of Separately installed Sediment/Pre Filter of size 20\\" i/c Leak testing, etc. complete as required at site i/c buyback of old dismantled material. |
| 32 | Supply, Replacement & ITC of Particulate/Sediment Filter of size 10\\" i/c Leak testing, etc. complete as required at site i/c buyback of old dismantled material. |
| 33 | Supply, Replacement & ITC of Pre/Post Carbon Filter of size 10\\" i/c Leak testing, etc. complete as required at site i/c buyback of old dismantled material. |
| 34 | Supply, Replacement & ITC of faulty SMPS 24 V/48 V etc. complete as required at site i/c buyback of old dismantled material. |
| 35 | Supply, Replacement & ITC of faulty RO Pump 48 V etc. complete as required at site i/c buyback of old dismantled material. |
| 36 | Supply, Replacement & ITC of faulty Solenoid Valve 48 V etc. complete as required at site i/c buyback of old dismantled material. |
| 37 | Supply, Replacement & ITC of faulty Compressor Unit i/c leak testing etc. complete as required at site i/c buyback of old dismantled material. |
| 38 | Supply, Replacement & ITC of faulty Fan Motor Unit etc. complete as required at site i/c buyback of old dismantled material. |
| 39 | Supply, Replacement & ITC of faulty Automated Switching ON/OFF device as per level of Water in Storage Tank/Water Cooler etc. complete as required at site i/c buyback of old dismantled material. |
| 40 | Supplying , replacement , testing and commissioning of Alkaline filter 20 \\" for water Dispenser for maintain the pH level etc complete as reqd at site i/c buyback of old dismantled material |
| 41 | Supplying , replacement , testing and commissioning of Alkaline filter 10 \\" for water Dispenser for maintain the pH level etc complete as reqd at site i/c buyback of old dismantled material |
| 42 | Supply, Replacement & ITC of faulty Push type chrome Plated Brass Tap i/c Leak testing etc. complete as required at site i/c buyback of old dismantled material. |
| 43 | (C) SH: Supplying and replacement of EI LED Fixture and WTAC/STAC as and when required at AyAM under juridiction of AE (E), HPESD-2, PWD, LBSHWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group C |
| 44 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.a) Group C |
| 45 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 46 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 47 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 48 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm) |
| 49 | 6 Module (200mmX75mm) |
| 50 | 12 Module (200mmX150mm) |
| 51 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 52 | 3 Module |
| 53 | 4 Module |
| 54 | 6 Module |
| 55 | 12 Module |
| 56 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 57 | 6 pin 15/16 amp socket outlet |
| 58 | 5/6 A switch |
| 59 | 3 pin 5/6 A socket outlet |
| 60 | Bell push |
| 61 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 62 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 63 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 64 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 65 | Double pole |
| 66 | Triple pole and neutral |
| 67 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 68 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. (Brush Less Direct Current (BLDC) Fan without Remote)a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 69 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)a)36 watt |
| 70 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt outputt . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflectora) 12 -15 watt |
| 71 | Supplying of 300/400 mm Sweep wall mounted oscillating Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc.as reqd. |
| 72 | Supply of 300 mm (Heavy duty) sweep exhaust fan 900 RPM in the existing opening including making good the damages, connection testing and commissioning etc. complete and dismantling etc. as required. |
| 73 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt outputt . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 100 watt |
| 74 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 18- 22 Watt |
| 75 | Supplying and replacement of 40 watt flying insect killer with complete UV tube, insect catch bug zapper replellent machine, high voltage current rectifier of size not less than 40 mmX 100 mm X 330 mm and full metel body weight not less than 6 kg i/c connection with proper 3 core cupper conductor cable i/c with heavy duty dash fastener and plug top etc. testing and commissioning and buy back the dismantled unit as required. |
| 76 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).(a) 1.5 TR with 5 Star BEE Rating |
| 77 | Supplying and laying of one number XLPE insulated and FR PVC round sheathed, un-armoured, Copper conductor power cable of 1.1 KV grade conforming to IS: 694 of following sizes for electrical connection of indoor and outdoor units for extend Main Supply of 1.5/2.0 TR Split Type AC as required. a) 4 X 2.5 Sq. mm |
| 78 | Supply including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (a) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 79 | (b) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 80 | SITC of following KVA capacity single phase, 230 volts, automatic voltage stabilizer complete with high-low cut off and time delay relay etc as required.a) 4KVA range 170-270V |
| 81 | Complete servicing of WTAC/STAC unit of 1.5 / 2.0 Tr capacity including dismantling the AC from its existing position i.e. various OPD's, Wards, ICU, OTs and various DA Dispensaries/Polyclinics etc, cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, greasing of motor, cleaning of drain pipe and refixing the same on its existing position complete etc. as required. (Qty taken for 2 years) |
| 82 | Repairing of PCB of remote control unit in the existing indoor unit of 2 TR/1.5TR Cap. STAC (Invertor Type)/WTAC of various makes i/c dismantling existing worn out PCB, connection, testing & buy back the old etc. as reqd. (as per sample) |
| 83 | Supplying & Charging of R-410a/R-22/R-32 refrigerant gas in existing following capacity WTAC / STAC unit i/c replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd.In 2 TR capacity |
| 84 | In 1.5 TR capacity |
| 85 | Supplying, Installation, testing and commissioning of following capacity cooling coil in the existing WT /Split AC unit complete with brazing the copper piping, pressure testing & gas charging etc. as required at site.& buy back the old etc. as reqd.a) 1.0/1.5 TR Cooling coil |
| 86 | b) 2.0 TR Cooling coil |
| 87 | Supplying, Installation, testing and commissioning of following capacity condenser coil in the existing WT /Split type AC i/c breezing the copper piping and fitting with screws, pressure testing & gas charging etc. as required at site.& buy back the old etc. as reqd.a) 1.0/1.5 TR Condenser coil |
| 88 | b) 2.0 TR Condenser coil |
| 89 | Supplying, Installation, testing and commissioning of following capacity Compressor in the existing WT /Split type AC i/c breezing the copper piping and fitting with screws, pressure testing & gas charging etc. as required at site.& buy back the old etc. as reqd.a) 1.0 TR/1.5 TR capacity |
| 90 | b) 2 TR capacity |
| 91 | Supplying and fixing 25 mm flexible drain pipe suitable for split and window AC units complete with necessary clamping on wall/floor for support etc. as per site requirement. |
| 92 | Supplying & Fixing of 18\\" Wall Mounted MS AC stand for outdoor unit including 6 Nos. M8X50 mm anchor fasteners, 4 Nos. M8X35 mm bolts with nuts and washer and 4 nos. mm M8X20 mm bolts with nuts and washer etc. complete as required at site. |
| 93 | Supply and installation of Centrifugal Monoblock Pump Set 1.5 HP, single phse, 230 volts, suitable having 50x40 mm suction & delivery, head range 15-33 m i/c P/fixing making foundation, suitable size union, nipple, elbow, nut & bolts i/c connection, interconnection etc. as reqd. (Make : Crompton /Kirloskar /V-Guard) |
| 94 | Supplying and fixing of DOL pump starter in stainless steel enclosure, Protection Degree IP 54 suitable for 1.5 HP motor priming pump set, Overload relay range 8.9- 13.5A ,2 pole contactor 16A, having Ammeter and Voltmeter, suitable for 230V,50 Hz, single Phase AC supply i/c testing etc as required. |
| 95 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 96 | Credit of following dismantled material and other accessories at site i/c dismantling from the existing site etc.LED Panel Light 2'X2'/ 1'X4' /down lighter/ LED Batten 40 W and 20 W etc. |
| 97 | LED Flood Light/Street Light/Insect Killer |
| 98 | Ceiling Fan/Exhuast Fan/Wall Fan etc. |
| 99 | 1.5 TR/2.0 TR STAC |
| 100 | 5 amp/15 amp Modular Switch and Socket/ Bell Push/Regulator/GI Box |
| 101 | MCB/TPN etc. |
| 102 | Monoblock/submersible pump set |
| 103 | Monoblock/submersible pump starter Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender