Tender For Replacement Of Bare Conductor By Ab Cable In 11 Kv Baheri Feeder Emanating From 33/11 Kv S/S Kichha Under Edd, Kichha Under The Head Of Capital (S.I.).( Rates Should Be Quoted Without Gst) (Gst Will Paid Extra)
Tender Overview
Project Description
Tender for Replacement Of Bare Conductor By Ab Cable In 11 Kv Baheri Feeder Emanating From 33/11 Kv S/S Kichha Under Edd, Kichha Under The Head Of Capital (S.I.).( Rates Should Be Quoted Without Gst) (Gst Will Paid Extra)
BOQ
| Sl. No. | Item Description |
| 1 | Annexure-A (LABOUR CHARGES) |
| 2 | Fabrication of MS Channel angle iron etc in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approved drawing. |
| 3 | Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all types of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 4 | Fixing, tightening and nozzling of stay with pole and stay rod on required tension as per drawing/manual in LT line |
| 5 | Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual. |
| 6 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all types of soil including proper dressing of sides and ramming of bottom including etting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 7 | Erection of SP-21 single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual. |
| 8 | Grouting of pole in size 0.45x0.45x1/9 of the support in CC ration 1:4:8(1 cement:4 graded stone20 mm niminal size: 8 coarse sand) block including cost of cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, levelling as per RESPO cnstruction manual. |
| 9 | Muffing of poles size 0.45x0.60 cm radius with 1:3:6(1 cement:3 coarse sand :graded stone 10 mm nominal size) block size 45 cm height from ground level including cost of cement,stone and sand etc. |
| 10 | Dismantling of existing LT line 1P 2W including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store(ACSR Weasel) |
| 11 | Dismantling of existing LT line 3P 4W including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store(ACSR Weasel) |
| 12 | Painting of SP-21/23 pole with angle and channel and all steel part by one coat of Red Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level. |
| 13 | Fixing of D type bracket on LT line. |
| 14 | Laying/Erection & Commissioning of LT Arial Bunch Cable of size 3x120+1x70 Sq.MM |
| 15 | Cartage of ST pole SP-21 Poles from store centre to construction site with loading, unloading at both points and proper stacking.(Distance 0-20 Km) |
| 16 | Cartage of other material (other than poles) by vehicle from Store Center to nearest construction site Store including loading and unloading at both ends (distance 0-20 Km) |
| 17 | Headload cartage of ST Pole SP-21 from road to site (distance 0-1 Km) |
| 18 | Head load cartage of small material (distance 0-1 Km) |
| 19 | Installation of LT Distribution Box 3 Phase for LT AB Cable. |
| 20 | Straightening of Tilted existing LT Poles as per Direction of Engineer in Charge. |
| 21 | Service of Hydra Machine for Lines & Transformer related work because of busy traffic in Town area for safety purpose. |
| 22 | Straightening of Tilted existing PCC Poles as per Direction of Engineer in Charge. |
| 23 | Tightening of stay set as per direction of Engineer in Charge. |
| 24 | Digging of Pit through Hammer at CC, Damar road as per direction of Engineer in Charge. |
| 25 | Fixing of mid span insulated Jointing sleeves for AB Cable |
| 26 | Fixing of Dead End Clamp as per Direction of Engineer in Charge. |
| 27 | Erection of Suspension Clamp as per Direction of Engineer in Charge. |
| 28 | Fixing of Piercing Connector L2L 120-120 Sq.MM. |
| 29 | Laying and fixing of 1x35sqmm XLPE Cable as per Direction of Engineer in Charge. |
| 30 | Disconnection & Reconnection of service connection 1PH. |
| 31 | Disconnection & Reconnection of service connection 3PH. |
| 32 | Fixing of Piercing Connector 120-95 Sq.MM. |
| 33 | Back Carriage of Scrap Material. |
| 34 | Lopping chopping of tree branches near HT/LT line. |
| 35 | Annexure-B (SUPPLY ITEMS)(As per UPCL Norms) |
| 36 | Supply of Cable Holding Clamp with N&B |
| 37 | Supply of Suspension Clamp with Eye Hook. |
| 38 | Supply of LT Bare N.Conn.PG. Clamp for DB 95-95 Sq.mm |
| 39 | Supply of Dead End Clamp with I Hook. |
| 40 | Supply of Stay Insulator. |
| 41 | Supply of insulated Piercing connector body molded from high quality mechanical climate and UV resistant glass reinforced polyamide, hot dipped galvanized bolts & contact teeth ABC size 120 Sqmm to 35 Sqmm TYCO/RPG/3M Make. |
| 42 | Supply of Share head type Insulated piercing connector L-L body molded from high quality mechanical climate and UV resistant glass reinforced polyamide, hot dipped galvanized bolts & contact teeth ABC size 120-120 Sqmm. |
| 43 | Supply of Stay Clamp with N&B |
| 44 | Supply of Connecting cable XLPE AL. 1x35 Sq.MM |
| 45 | Supply of LT Arial Bunch Cable 3x120+1x70 Sq.MM |
| 46 | Supply of SMC Three Phase L.T. Distribution Box with inbuilt panal lock, Al bus bar RYB 25x6mm., Al Busbar N. 40x6mm. for connection of L.T. consumer (Sintex/RMC make or other ISO reputed company) with Panel Lock with key) (As per drawing attached) |
| 47 | Supply of Jointing Sleeve 10MM |
| 48 | Supply of Al. Crimping type Lugs 35 SQ.MM |
| 49 | Supply of MS Half Clamp for LT Distribution Box Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender