Tender For Construction Of Godown (Rcc Roof) At- Blt & Ec, Barkote, District - Deogarh
Tender Value
33.59 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
11 days left
EMD
33599
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Deogarh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Godown (Rcc Roof) At- Blt & Ec, Barkote, District - Deogarh
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation of foundation in all kinds of soil within 50 m initial lead and 1.5 m initial lift including rough dressing and breaking rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 m in depth including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work etc. complete as per the direction of the Engineer In Charge. |
| 2 | Supplying, Filling sand in foundation & plinth with Sand watered and rammed including cost, conveyance, taxes, royalty of sand, labour & T&P etc. complete as per specification and direction of the Engineer In Charge. |
| 3 | Cement Concrete (1:4:8) by using 40 mm size hard granite crusher broken chips of approved quality and form approved quarry including lowering laying concrete, watering and curing etc. complete for required levels laid in layers including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work including watering & curing, etc. complete as per the direction of the Engineer In Charge. |
| 4 | Plain Cement Concrete (1:2:4) using 12mm size hard granite crusher broken chips of approved quality and from approved quarry including lowering laying concrete, watering and curing etc. complete for required levels laid in layers including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work including watering & curing etc. complete as per the direction of the Engineer in Charge. |
| 5 | Providing Fly Ash brick masonry work in foundation using 230 mm X 110 mm X 80 mm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand) (Using Branded Cement), immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. complete as per the direction of the Engineer In Charge. |
| 6 | Reinforced Cement Concrete (M20 grade) with 20mm & down graded size hard granite crusher broken chips of approved quality and from approved quarry including centring, shuttering, lowering, laying concrete, watering and curing etc. complete for required levels laid in layers including cost, conveyance, royalty and taxes of all materials and cost of labour, T&P,Labour Welfare cess @1% required for the work etc. complete as per specification and direction for the Engineer In Charge. |
| 7 | Column foundation |
| 8 | plinth Beam |
| 9 | Lintel |
| 10 | Roof beam |
| 11 | Column |
| 12 | Chajja |
| 13 | Roof Slab |
| 14 | Supplying, fitting and placing MS round/ deformed/ tor steel HYSD bar reinforcement of only approved manufacturing companies of approved grade of required diameters of approved quality complete in proper position including cost of binding wire 18 to 20 gauge as per direction of Engineer In Charge. |
| 15 | Providing Fly Ash brick masonry work in using in superstructure 230 mm X 110 mm X 80 mm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand) (Using Branded Cement), immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. complete as per the direction of the Engineer In Charge. |
| 16 | 2.5cm.grading concrete (1:2:2) on roof slab using 6mm.size CBHG chips on new work |
| 17 | 6 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction for the Engineer In Charge. |
| 18 | 16mm thick cement plaster in cement mortar (1:6) to inside of brick walls surface after racking out the joints curing and watering with all cost etc.complete |
| 19 | 12 mm cement plaster in cement mortar (1:6)including necessary scaffolding curing etc. in Foundation and Superstructure as per direction of Engineer In Charge. |
| 20 | Priming one coat with cement primer water bound complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction for the Engineer In Charge. |
| 21 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work , etc. complete as per the direction for the Engineer In Charge. |
| 22 | Fitting vitrified tiles in floors,treads or steps and landing on 25mm thick bed of cement mortar(1:1) joined with neat cement slurry mixed with pig ments including cost of tiles |
| 23 | Fitting vitrified tiles in dadoes skirting and riser of steps on 12mm thick cement plaster(1:3) joined with neat cement slurry mixed with pigments to match the shade of tiles including rubbing &polishing complete including cost of tiles |
| 24 | Supply and fixing of MCM Modified Clay Material - MCM R Series Brick (087089) - 222 x 63 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge. |
| 25 | Supplying, fitting & fixing in position & drawing of Window (sliding type) made of aluminum section 9778 as windows frame section No. 4095, 4096, and 9777, 3994 as shutter frame with 5 mm thick black glass as panel fitted with rubber bending including locking arrangement including all fitting complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction for the Engineer In Charge. |
| 26 | Supplying and fixing of MS window grill and grill gate including cost of fabrication and cost, conveyance, taxes etc. complete. |
| 27 | Priming one coat to surface with Red oxide Primer including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction for the Engineer In Charge. |
| 28 | Painting two coats with approved enamel paint on iron work including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction for the Engineer In Charge. |
| 29 | Providing, fitting and fixing of false ceiling with 12 mm thick gypsum board, Aluminium anodised T Section No. 3215 with 2'-0\\" centre to centre, L section No. 1705 up to 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2'-0\\" x 2'-0\\" suspended from ceiling etc. complete. (Data for 14'-6\\" x 14'-6\\" = 210.25 sft or 19.53 sqm) |
| 30 | Filling foundation and plinth with excavated materials. |
| 31 | Internal Electrification |
| 32 | Recresed wiring to light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated single standard multistandard copper conductor of ISI marked and ceilling rose ISI marked mounted on MS box having front modular cover of suitable size MS modular box with 1.0 sqmm FR PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer In Charge. |
| 33 | Group-A |
| 34 | Group-B |
| 35 | Supplying and fixing of 5/6 amp one way modular type switch on existing switch box/cover including connections etc as required. |
| 36 | Supplying and fixing of 5 pin 5/6 amp socket outlet modular type switch on existing switch box/cover including connections etc as required. |
| 37 | Supplying and fixing of 15/16 amp one way modular type switch on existing switch box/cover including connections including all accesories and connection as per direction of Engineer-in-charge. |
| 38 | Recessed wiring for 6 pin 15/16 amp modular socket outlet with 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge. |
| 39 | Supplying and fixing batten holder/BK angle holder modular type ISI marked including connection etc including all accesories and connection as per direction of Engineer-in-charge. |
| 40 | Installation, testing and commissioning of pre-wired 12 W LED Light fitting of all sizes complete with all accessories etc. directly on ceiling, excluding connection and earthing |
| 41 | Installation, testing and commissioning of ceiling fan ( 48\\" decorative), including wiring the down rods of standard length (up to 30 cm) etc. as required. |
| 42 | Installation, testing and commissioning of stepped type modular fan regulator, in existing switch box including connection with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor, earthing the regulator |
| 43 | Supplying and fixing of 25 mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender