Tender For Repairs To Sewage False Ceiling Plumbing Roof And Allied Services Of 6 Vikas (Ravangla) Under Ge 867 Ews.
Tender Value
30 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
17 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South District → Sikkim
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Sewage False Ceiling Plumbing Roof And Allied Services Of 6 Vikas (Ravangla) Under Ge 867 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for foundation etc. and getting out in Soft/loose soil. |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out in hard and dense soil. |
| 3 | Excavating over areas, exc 1.5 m deep and n.exc 3m deep and getting out in hard and dense soil. |
| 4 | Returing filling in including spreading levelling watering and well ramming in layers n.exc 25cm in soils. |
| 5 | Removing of excavated materials n.exc 50mtr and depositing where directed at a level n.exc 50 mtr above the starting point in soils. |
| 6 | Cement concrete 1:4:8 Type D2 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified. |
| 7 | M & L Plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in benching of drain, MH inluding necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for cement concrete Type B-1, (1:2:4) (using 20mm graded stone aggregate) as in Coping, kerbs for MH etc complete all as specified and directed. |
| 9 | Demolition and breaking up 100/110mm old broken PVC (SWR), AC, SWG soil waste and vent pipe including accessories set in cement mortar and removing rubbish from site as directed Engineer-in-Charge complete all as specified and as directed. |
| 10 | S & F 100mm cast iron soil waste and vent pipes (sand cast) in any length with or without ears laid in trenches or in floors complete all as specified. |
| 11 | S&F of 110mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed (Note : Excavation and earth work measured and paid separately) |
| 12 | M & L PCC (1:3:6), type C-2 conrete bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested in 100mm/ 110mm dia complete all as specified. |
| 13 | S & F Cast iron bends (any radius) diminishing pieces or taper 100mm bore complete all as specified. |
| 14 | Cleaning of exsting choked sewage line of pipe 100/110 mm bore by rodding and watering and taking out sluge througe manholes etc. complete and disposal of same to a previously dugged out pit after filling the upper surface with earth and 2 cm thick lime over filled earth including sprinking of bleaching power complete all as specified. |
| 15 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided. |
| 16 | M&L RCC (1:2:4) (nominal mix) (using 20mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified. |
| 17 | M&L precast cement concrete type-B-1 (1:2:4) (20 mm graded aggregate) in drain cover slab for man holes etc chullas hoods , chhajas, water troughs, mangers, shelves and similar articals with plain faces set in cement morter (1:6) complete all as specified. |
| 18 | M&L Mild steel TMT bars 6 to 8 mm dia,cut to length,bent to shape required,including cranking, bending spirally for hopping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia complete all as specified. |
| 19 | M&L Mild steel TMT bars 10 mm dia and over,cut to length,bent to shape required, including cranking, bending for rungs/hooks in manhole cover complete all as specified. |
| 20 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) rough finish complete all as specified. |
| 21 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified. |
| 22 | Cutting into existing manholes for connecting new drains of dia 100/110mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required. |
| 23 | Cutting into existing manholes for connecting new drains of dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required. |
| 24 | Cleaning existing man holes, septic tank etc by dewatering and taking out sludge and solid deposits from the septic tank and man holes etc completely and browing the sludge and solid diposited in a nearly dug pit with in 100mtr and covering the sludge and solid deposited etc with earth and 2cm thick lime on top surface to prevent spread of foul smell after taking out sludge and solid deposits, the inside of the septic tanks manholes etc should be cleaned with water all as directed (Note:1.Volume of sludge by Engr- in - charge. |
| 25 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, ashlar facings,dressed stonework, precast concrete articles and precast concrete block walling complete all as specified and directed. |
| 26 | Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed. |
| 27 | M & L 15 mm thick rendering onfair faces of brick work concrete surface in CM (1:3) with water proofing compound. Note : WPC will be measured and paid separately. |
| 28 | M & L 10mm thick rendering on fair faces of brick work or concrete surface in CM (1:4) complete all as specified. |
| 29 | M & L 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:6) including taking down cement plaster of any description from stone/ PCC blocks taking down cement plaster of any description from stone/PCC block/brick walls incl raking out joints hacking for key, scrubing down with water etc complete all as specified and directed. |
| 30 | M & L 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:4) including taking down cement plaster of any description from stone/ PCC blocksTaking down cement plaster of any description from stone/PCC block/brick walls incl raking out joints hacking for key, scrubing down with water etc complete all as specified and directed. Note - WPC will be measured and paid separately. |
| 31 | Supply only integral water proofing compound. |
| 32 | M & L three coats of white wash on newly plastered surfaces including preparation of surfaces complete all as specified. |
| 33 | Demolition of cement concrete Unreinforced) in ground floor and pavings n exc 15cm thick ness (below or above ground level) all as specified and as directed. |
| 34 | M&L for PCC type C2 (1:3:6) using 40 mm graded stone aggregate) in surface channels and drain etc, complete all as specified and as directed. |
| 35 | M & L for forming fair finished drain or channel 30 cm or over inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified. |
| 36 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 37 | Material & Labour for providing and fixing stainlesssteel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessarystainless steel nuts and bolts complete, includingfixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor orthe side of waist slab with suitable arrangement. |
| 38 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed withearth around, in layers not exceeding 25 cm complete all as specified. |
| 39 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 40 | S&F 605 X605 mm GI frame work for for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sorrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from suffit at approx 900 mm centre to centre with GI cleats and steel expansion fastner with and including ceiling section (not exc 1.2 m length)of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10 .5 mm fixed to the intermediate channel with connecting clieats across the intermediate channel at 457 mm centre to centre. |
| 41 | M&L 4mm thick asbestos cement plain building boards, fixed or laid /inserted to GI snap grid framework with screw in ceilings complete all as specified. |
| 42 | M&L three coats of white wash on ceiling on AC boards complete all as specified. |
| 43 | S&F Plywood 12mm thick 3 no of ply, grade BWR, type BB, fixed with nails to timber frame work complete all as specified and as directed. |
| 44 | Dismantling timber scantlings 40 sq. cm and over in section, in any position in unframed work complete all as specified and as directed. |
| 45 | M & L 2nd class hard wood in scantling fixed in clean sawn complete all as specified and as directed. |
| 46 | M&L Preparation of new wooden surface and apllying two coats of synthetic enamel paint complete all as specified and directed. |
| 47 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 48 | S & F pre painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 49 | S & F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 50 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 51 | S&F roof trusses, framed trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (Beam, tee, angle channel or flat section) incl distance pieces, cleats, nut and bolts conforming to FE-410w (grade 250-E quality A) complete all as specified. |
| 52 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 53 | S&F 1.25mm thick Mild steel sheet / PVC eaves gutters, 150mm dia, galvanised class 3, half round with rounded edges complete all as specified. |
| 54 | S&F 150mm dia Mild steel sheet of 1.25mm thk/ PVC drop ends (for spigot or socket ends) or nozzles complete all as specified. |
| 55 | S&F 150mm dia Mild steel sheet of 1.25mm thk/ PVC stop ends (for spigot or socket ends) or nozzles complete all as specified. |
| 56 | Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 57 | S&F 15mm bore steel water tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified. |
| 58 | S & F in repair 15 mm dia bib taps,chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 59 | S & F in repairs 15mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 60 | S & F in repair 15mm dia Stop valves, cast copper alloy,fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 61 | S & F in repair 15mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 62 | S & F in repair 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 63 | S & F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified. |
| 64 | S & F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including provision of lime concrete bedding complete all as specified and directed. |
| 65 | S & F in repair vitreous china, wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified. Please Enable Macros to View BoQ information |
| 66 | S & F in repair vitreous china, wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender