Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56841100

Tender For Repair And Maintenance Of Street Lightning, Security Lightning And Allied Works Under Ge(A) Jaisalmer

Issued by Statutory Bodies & Commissions/Committees · Jaisalmer, Rajasthan
Tender Value
51 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
10 days left
EMD
1.01 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Street Lightning, Security Lightning And Allied Works Under Ge(A) Jaisalmer

BOQ

Name of Work:- REPAIR AND MAINT OF STREET LIGHTNING, SECURITY LIGHTNING AND ALLIED WORKS UNDER GE(A) JAISALMER
Sl. No. Item Description
1Taking down unservicable street light/ flood light/ solar light/post top lantern fitting of any size /type/capacity any Watt from height of pole/walls/for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified.Note :- (a) Spares like LED Driver,surge protector ,service wire etc. shall be measured and paid as separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost.(c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site.
2Supply only of electronic driver for LED light fitting, LED out put power 30 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range: 24 volt to 110 volt, make as per site requirement complete all as specified.
3All as per item No 2 above but capacity 45 watt
4All as per item No2 above but capacity 60 watt
5All as per item No 2 above but capacity 70 watt
6All as per item No 2 above but capacity 90 watt
7All as per item No 2 above capacity 200 watt
8All as per item No 2 above capacity 250 watt
9All as per item No 2 above capacity 400 watt
10Supply and fix in repair Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified.
11Labour only for making serviceable street/security lights/solar light unserviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire complete all as specified Note : - Cable shall be measured and paid seprately.
12Supply And Fixing in repair Led Street Light Of Capacity 45 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge. Make – Crompton/Havells/Wipro Cat No crompton CRP-409-45-57-SL-GL-NSG or Equivalent in Appx c
13Supply And Fixing in repair Led Street Light Of Capacity 60 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt with toughend glass , Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge. Make – Crompton/Havells/ Wipro crompton cat No CRP-409-60-57-SL-GL-NSG or Equivalent in appx c
14Supply And Fixing in repair Led Street Light Of Capacity 90 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt with toughend glass , Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge. Make – Crompton/Havells/ Wipro crompton cat No CRP-411-90-57-SL-GL-NSG or Equivalent in Appx c
15Supply & Fixing Led Flood Light Fitting 200 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X …….. Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make – Crompton/Havells/Wipro Crompton Cat no TFS-507-200--57-60 D-SL-GL-NSG or Equivalent in Appx c
16Supply & Fixing Led Flood Light Fitting 250 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 2.5 Sqmm Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make Crompton/Havells/Wipro– Crompton Cat no CFS-506-250-57-30 D-HL2-GL-NSG ,or Equivalent in Appx c
17Supply & Fixing Led Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 48,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, , Cct – 5700k, Of Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Seperate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 2.5 Sqmm Frlsh Wire, All As Per Directed By Eic all as specified and directed by Engr-in-Charge Per Make Crompton/Havells/Wipro – Cat no CFS-512-400-57-30 D-HL2-GL-NSG ,or Equivalent in Appx c
18Supply and fixing in replacement of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified.
19Supply and fixing in replacement of PVC insulated, sheathed weather proof, aluminium conductor of size 6 sqmm, 2 core complete all as specified.
20M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified.
21supply & erect minimum 9 mtr height above GL Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) and including one coat of red oxide primer and two coat of aluminium paint over a pole including dismantlaing/taking out existing PCC/Steel tubular pole and making surface good complete all as specified and directed by Engr -in-Charge.
22M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engr-in-Charge.
23M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of PCC pole /stay assembly including necessary form work up to groud level all as specified and directed by Engr-in-Charge.
24M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
25Supply ,laying, test and commissioning in repair of LT UG ,XLPE insulated, heavy duty, 1100V grade of electric cable size 50 Sqmm 3.5 core with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs,bushing etc as required complete all as specified and directed by Engineer-in -Charge of following size:-Note: Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.
26(a) All as above item no 25 but size 10 Sqmm 2core
27(b) All as above item no 25 but size 10 Sqmm 4core
28(c) All as above item no 25 but size 16 Sqmm 4core
29(d )All as above item no 25 but size 25 Sqmm 4core
30(e) All as above item no 25 but size 35 Sqmm 3.5 core
31(g) All as above item no 25 but size 70 Sqmm 3.5 core
32(h) All as above item no 25 but size 95 Sqmm 3.5 core
33M & L in repair HDPE DWC pipe ISI marked fixed on walls,ceiling , in floor,trenches etc for laying of cable protection of the following outer dia
34a) 40 mm dia
35b) 50 mm dia
36c) 63 mm dia
37d) 90 mm dia
38Taking out and relaying of old retrieved servicable LT UG cable of any size /any core including pipe or cable cover or DWC pipe complete all as directed by Engr -in- charge. Note : Earth work & other items will be measured and paid separately.
39Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or soil for shaft walls,cesspits ,manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft /Disintegrated type of soil/ any type of soil complete all as specified & directed by Engr-in-Charge.
40Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft /Disintegrated type of soil/ any type of soil complete all as specified & directed by Engr-in-Charge.
41Removing excavated Material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point of soft /Disintegrated type of soil/ any type of soil complete all as specified & directed by Engr-in-Charge.
42Supply & fix in repair 40 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified and as directed.
43Supply & fix in repair 50 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and as directed.
44Supply and Fixing in repair of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and complete all as specified.
45S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings all as directed by Engr-in-Charge.
46Supply & fix in repair MCB, single pole, 16-32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge.
47Supply & fix in repair MCB, SPN, 32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge.
48Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 40 Amp, Complete all as specifed and directed by Engr-in-Charge.
49Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 63 Amp, Complete all as specifed and directed by Engr-in-Charge.
50Supply & fix in repair MCCB 415V, 3 phase 50 HZ 4 pole 100 Amps breaking capacity 16 KA (Ics = 100% Icu) with including dismantling old one connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
51Supply & Fix in repair MCCB 415V, 3 phase 50 HZ 4 pole 125 Amps breaking capacity 16 KA (Ics = 100% Icu). connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge
52Material and labour for straight through(Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10/16 SQmm including dismantling the old burnt cable joint termination Complete all as specifed and directed by Eng-in-Charge..
53(a) All as above item no 52 but size 25 Sqmm 4 core
54(b) All as above item no 52 but size 50 Sqmm 3.5 core
55(c) All as above item no 52 but size 70 Sqmm 3.5 core
56(d) All as above item no 52 but size 95 Sqmm 3.5 core
57Material and labour for preparation of old painted surface of LT Concrete electric pole of size 9 mtr height by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height 1.5 mtr above the ground level, including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and235 writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge.
58Material and labour for preparation of old painted surface of LT Steel tubular pole of size 9 mtr height by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge.
59Supply and fix in repair Din type HRC fuse link of Required rating 32A/63A/100A Suitable for HG type 20H/2 complete all as specified & directed by Engr-in-Charge.Make:-Seimens/L&T/Havells.
60S & F in replacement of Street light nature switch (using infrared sensor technology) based automatic street light control panel. the panel shuld be suitable enough to take 3 Phase load of 8 KW. Nature switch operation should be based on natural light Lux* level. required illuminance level for switching ON is ≤ 60 Lux and for switching off ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor alongwith suitable 3 Nos power Contractors and 03 Nos incoming MCB's 40 Amp & 3 Nos outgoing MCB's of 32 Amp each & circuit wiring (Copper) of min 10 sqmm with lug should be enclosed in a pole/wall mountable rust proof, electric shock proff, termite proof and FR grade SMC elclosure confirming to IP 66. The circuit should also have provision for Manual operation (i.e. Sensor by Pass option) and incl taking down old one complete all as specified.
61S & F in replacement of Street light nature switch (using infrared sensor technology) based automatic street light control panel. the panel shuld be suitable enough to take 3 Phase load of 12 KW. Nature switch operation should be based on natural light Lux* level. required illuminance level for switching ON is ≤ 60 Lux and for switching off ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor alongwith suitable 3 Nos power Contractors and 03 Nos incoming MCB's 32 Amp & 3 Nos outgoing MCB's of 32 Amp each & circuit wiring (Copper) of min 10 sqmm with lug should be enclosed in a pole/wall mountable rust proof, electric shock proff, termite proof and FR grade SMC elclosure confirming to IP 66. The circuit should also have provision for Manual operation (i.e. Sensor by Pass option) and incl taking down old one complete all as specified.
62S&F in replacement of Street light nature switch ( using infrared sensor technology ) based automatic street light control panel. The panel should be enough to take three phase load of 25 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is <=60 and for Switching OFF >=10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation . complete all as specified and directed by Engr-in-Charge. (Make :- Kakatiya Energy system (sw , Indoasian, L&T).
63Supply & fix in repair MNX Power contactor suitable for power supply 40 Amps 4 pole 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make: Legrand or equivalent make of Havells/L&T.
64Supply & fix in repair MNX Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make: Legrand or equivalent make of Havells/L&T.
65S&F in repair Digital Astronomical timer switch 240V AC-2W,C/O, Base/DIN type complete for switching of contactors complete all as specified and directed by Engineer-in-charge.
66M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified.
67S& F in repair Lithium based energy efficient Integrated solar street light of 20 watt in single body with FRP/Aluiminum duly polyurenthane coating encases with monocrystalline solar PV panel of 30/35Wp, Lithium battery 11.1/12.8 Volt, 24 Ah with inbuit BMS, IP 65/66, High brightness W-LED (120-180 Im/Watt) lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 K-6500 K, Microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor,Dusk to dawn operation weight not more than 10-12 KG with adjustable MS Clamp suitable for existing pole/wall mounting etc complete all as specified and directed by Engr-in-Charge. including dismantlingand /taking down old one Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & TOHS complaint. Please Enable Macros to View BoQ information
68S& F in repair Lithium based energy efficient Integrated solar street light of 20 watt in single body with FRP/Aluiminum duly polyurenthane coating encases with monocrystalline solar PV panel of 30/35Wp, Lithium battery 11.1/12.8 Volt, 24 Ah with inbuit BMS, IP 65/66, High brightness W-LED (120-180 Im/Watt) lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 K-6500 K, Microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor,Dusk to dawn operation weight not more than 10-12 KG with adjustable MS Clamp suitable for existing pole/wall mounting etc complete all as specified and directed by Engr-in-Charge. including dismantlingand /taking down old one Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & TOHS complaint. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56841100
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 51 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Street Lightning, Security Lightning And Allied Works Under Ge(A) Jaisalmer
Basic Detail
Tender No 84472/C/E8
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 05 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 51 Lakhs
Tender Fee 1000
EMD 1.01 Lakhs
Exemption Available
Document List
868f39c0-813a-4189-9a02-bbe1cf6e33c5.html
BOQ_876977.xls
TENDER1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

868f39c0-813a-4189-9a02-bbe1cf6e33c5.html

xls

BOQ_876977.xls

pdf

TENDER1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail