Tender For Addition / Alteration In Kitchen And Provisioning Of Two Gazebo In Sailors Institute,And Provision Of Weather Proof Sheds For Duty Po(Security)And Duty Qm Posts At Main Guard Room And Sub Guard Room, And As And As To Regulating Office ( P
Tender Overview
Project Description
Tender for Addition / Alteration In Kitchen And Provisioning Of Two Gazebo In Sailors Institute,And Provision Of Weather Proof Sheds For Duty Po(Security)And Duty Qm Posts At Main Guard Room And Sub Guard Room, And As And As To Regulating Office ( P - 54 ) And Security Office ( P - 55 ), And Provision Of New Hardstand Pathway With Shed For Regulating Office At Admin Building P - 54 At installation Rajali, Arakkonam.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Aug-2026 | BOQ | BOQ | 25-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 2 | Material and labour for joint free non skid ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 3 | M&L for glazed ceramic coloured tiles 350 x 250mm x7mm/450 X 350 X 7mm thick as in dados set and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat 10mm thick plaster on fair faces of brick work/ concrete in CM 1:4 to receive tiles as in dado complete all as specified and as directed.. |
| 4 | M & L Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match with screed bed 15 mm thick laid in 1:6 CM complete all as specified and as directed. |
| 5 | All as per Item no.4 but in vertical surfaces such as skirtings, dados etc.,including rendering 10mm thick plaster on fair faces of brick work/concrete in CM 1:4 to receive tiles as in Skirting/Dado complete all as specified and as directed. |
| 6 | Taking down chowkats or frames of any description with shutters (without taking off shutters from the frames) area n exc 1.5 Sqm each all as specified and as directed and making good the disturbed plastered surfaces with 10 mm plaster in CM 1:6 and final finish as per existing complete all as specified and as directed. |
| 7 | Taking down chowkats or frames of any description with shutters (without taking off shutters from the frames) area exceeding 1.5 Sqm but n exc 4 sqm each all as specified and as directed and making good the disturbed plastered surfaces with 10 mm plaster in CM 1:6 and final finish as per existing complete all as specified and as directed. |
| 8 | S & F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed. |
| 9 | S&F factory made 35mm thick second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 10 | S&F second class hard wood 30mm Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 11 | S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 12 | S&F 100 mm butt hinges, medium weight, Cold rolled mild steel fixed complete all as specified and as directed. |
| 13 | S&F 200 mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 14 | Supply and fix door handle, 150mm size, aluminium alloy, complete all as specified and as directed. |
| 15 | S & F of Floor door stopper 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed. |
| 16 | Supply and fix powder coated anodised aluminium frame for sliding doors ,windows , ventilators with one or more rebates mimimum thickness of powder coating 50 micron) including joining cleat for fixing etc,complete all as specified and as directed. Notes : (i) All the aluminium sections provided under this item shall be measured and converted into weight for payment with the designated unit weight mentioned in the manufacturers catalogue for the corresponding aluminium sections/fittings.(ii) The rate quoted deemed to include necessary grouting/ embedding of the aluminium frames/supports into floors/walls and making good the disturbed surfaces to match with the existing surfaces and provision of necessary rubber gaskets complete all as specified and as directed. |
| 17 | Supply and fix powder coated anodised sliding/hung type aluminium window and ventilator shutters (minimum thickness of powder coating 50 micron), without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2Nos) suitable handle (1 No), aluminium tower bolt 100 mm (1No) etc. complete all as specified and as directed. |
| 18 | S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 19 | S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed. |
| 20 | S & F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed. |
| 21 | M&L Preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 22 | Demolition of stone slabs and tiles of any description or any thickness in floors, skirtings, risers etc laid ,bedded and pointed in any mortar complete all as specified and as directed. |
| 23 | M & L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry in floors and pointed with white cement with admixture of pigment to match the shade of granite stone laid & jointed over and including 20mm cement screed in CM 1:6 complete all as specified and as directed. |
| 24 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 25 | Taking up or down steel tubing 20mm dia bore and connection including cleaning for refixing or removal complete all as specified and as directed. |
| 26 | Supplying and laying in repairs 20mm dia steel tubing galvanised with all fitting and fixed complete to wall and ceiling complete all as specified and as directed. |
| 27 | S & F in repair 20 mm bore fancy type Chromium plated Bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 28 | M&L 2nd class hard wood plain fillets. square, rectangular or triangular in section, clean sawn, secured with screws with nails exc 13 sqcm but n exc 25 sqcm complete all as specified and as directed. |
| 29 | S&F in 18 mm thick prelaminated particle board , Interior grade, prelaminated double side with decorative choice lamination , fixed with screws to timber frame work as in cup board shelves etc complete all as specified and as directed. |
| 30 | &F 75 mm butt hinges, medium weight, Cold rolled mild steel fixed complete all as specified and as directed. |
| 31 | S&F 100 mm size,Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 32 | S&F 75 mm size,Hasp and staple, safety type, of aluminium anodised hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed. |
| 33 | S & F for ball catches of 8mm dia steel brass body and striking plates approved pattern fixing to the cupboard shutters, including lettering complete all as specified and as directed. |
| 34 | Material and labour for 70mm thick plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub base complete all as specified and as directed. |
| 35 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 36 | S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete Fe 410-W (Gde E- 250 quality A complete all as specified and as directed. |
| 37 | M & L two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth including necessary preparation of surfaces complete all as specified and as directed. |
| 38 | Excavating soft/loose soil in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete all as specified and as directed. |
| 39 | Material and labour for Cement concrete in foundations, filling and mass concrete type C-2, 1:3:6 (Using 40mm graded stone aggregates) complete all as specified and as directed. |
| 40 | M & L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius , built in cement mortar 1:4 complete all as specified and as directed. |
| 41 | M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed. |
| 42 | M & L for Cement concrete 1:4:8 in type D2 40 mm graded aggregate in base subbase with thickness 100 mm, etc complete all as specified and as directed. |
| 43 | Material and labour for designer Chequered cement concrete tiles 30cm x30cm x 25mm thick with pigments,set, jointed and pointed in neat cement slurry in floor over 20 mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed. |
| 44 | M & L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick wall , built in cement mortar 1:4 complete all as specified and as directed. |
| 45 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures, PVC conduits and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials from wall/ceiling etc to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. complete all as specified and as directed. |
| 46 | Material and labour for Point wiring with 1.5 sqmm (Nominal area) unsheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into existing concealed conduit through Wall/Ceiling/Flore along with FRLS 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly etc complete for for the following point wiring and making good disturbed surfaces matching with existing paint complete all as specified and as directed. |
| 47 | One light/fan point controlled by one switch with cable 1.5 Sqmm size.. |
| 48 | All as per item ser No-46 above here in before but one 3 pin socket outlet 6 Amps, same board with cables 1.5 Sqmm size. |
| 49 | All as per item ser No-46 above here in before but one 3 pin socket outlet 6 Amps, independent board with cables 2.5 Sqmm size. |
| 50 | All as per item ser No-46 above here in before but one 5/6 pin socket outlet 6/16 Amps, indipendent board/AC/Geyser with cables 4 Sqmm size. |
| 51 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into including PVC conduit of minimum 20 mm dia concealed/surface wiring through Wall/Ceiling/Flore etc including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc and making good disturbed surfaces matching with existing paint incl plaster work complete for the following. |
| 52 | One light/fan point controlled by one switch with cable 1.5 Sqmm size.. |
| 53 | All as per item ser No-47 above here in before but one 3 pin socket outlet 6 Amps, Independent board with cables 2.5 Sqmm size. |
| 54 | S&f modular white cover plate with frame, 3 module complete all as specified and as directed. |
| 55 | S&f metal box, 3 module complete all as specified and as directed. |
| 56 | S&f modular white cover plate with frame, 4 module complete all as specified and as directed. |
| 57 | S&f metal box, 4 module complete all as specified and as directed. |
| 58 | S&f modular white cover plate with frame, 8 module complete all as specified and as directed. |
| 59 | S&f metal box 8 module complete all as specified and as directed. |
| 60 | S&f modular white cover plate with frame, 12 module complete all as specified and as directed. |
| 61 | S&f metal box 12 module complete all as specified and as directed. |
| 62 | S&F for switch modular 1 way 6Amp 1 module complete all as specified and as directed. |
| 63 | Supply and fixing Modular socket 6 Amp, 3 pin Active white two module complete all as specified and as directed. |
| 64 | Supply and fixing Modular switch one way 16 A white Active one module complete all as specified and as directed. |
| 65 | Supply and fixing Modular socket 16 A, 5 pin multi purpose Active white two module complete all as specified and as directed. |
| 66 | S&F for ceiling rose three terminals/ PVC/ polycarbonate, isolated body complete all as specified and as directed. |
| 67 | Supply and fixing LED lights fitting 1x 18W 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 68 | Supply and fixing wall mouned swing fan, single phase, 230V of size 300mm complete all as specified and as directed. |
| 69 | M&L for sheet metal encloser double door for DB when MCB to be fixed SPN 2 way with 200 amp busbar complete all as specified and as directed. |
| 70 | M&L for sheet metal encloser double door for DB when MCB to be fixed SPN 8 way with 200 amp busbar complete all as specified and as directed. |
| 71 | Supply and fix for MCB SPN 230 V, 25-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed. |
| 72 | Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed. |
| 73 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for taking up / laying cable etc and getting out for soft/loose soil complete all as specified and directed. |
| 74 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as specified and as directed. |
| 75 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 76 | Supply and lay DWC (Double Wall Corrugated) Duct pipe of 50 mm dia in trenches/under road or floor/on wall / near pole/panel etc all as per site requirement complete all as specified and directed. |
| 77 | Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables with aluminium conductor of size 16 sqmm 2 core, connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel / DB etc all as per site requirement , testing complete all as specified and directed. |
| 78 | M&L for tubes light grade galvanised iron pipes of 40 mm sizes with all fittings and fixed to wall/ pole / under road / culvert / drain or laid in floors,complete incl taking the corroded complete all as specified and as directed. |
| 79 | M & L for plain cement concrete type C1 1:3:6 (using 20 mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 80 | S&F Steel work in tubular trusses including special shaped washer,ms plates, nuts and bolts, drilling holes, bolting or reviting etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 81 | S & F wind ties for roof including securing bolts, posts and struts, including cutting tops to shape as directed, drilling holes, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 82 | S&F 150mm Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edge thickness of sheet 1mm and necessary drop and stop end providing complete all as specified and directed. |
| 83 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 84 | M & L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 85 | Material and labour for two coats of synthetic enamel paint over one coat of red oxide priming including preparation of new steel surfaces n exc 10 cm in width or girth, not otherwise described complete all as specified and as directed. |
| 86 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into including PVC conduit/ casing caping/ fixed on wall/roof/ceiling etc of size not less than 20 mm dia including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete all as specified and as directed for the following :- |
| 87 | One light point controlled by one switch. |
| 88 | One fan point controlled by one switch. |
| 89 | All as per item ser No-82 above here in before but One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size complete all as specified and as directed. |
| 90 | M&L for sub main wiring for phase and neutral with PVC FRLS insulated unsheathed multi stranded along with earth wire FRLS PVC insulted copper conductor, single core cable in and including surface/concealed /PVC conduit of appropriate size complete all as specified and directed for the following sizes. Note:- : 1. Cutting chases for concealed wiring shall be measured and paid seperately. 2. Rates are including taking down old unserviceable. |
| 91 | 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire |
| 92 | Supply and fixing of Plastic surface box suitable for mounting moduler plate of following modules complete all as specified and directed:- |
| 93 | 3 Module |
| 94 | 4 Module |
| 95 | 8 Module |
| 96 | Supply and fixing of combined both frame and cover plates fixing on mounting boxes for following modules complete all as specified and directed:- |
| 97 | Cover plate with frame,3 Module |
| 98 | Cover plate with frame,4 Module |
| 99 | Cover plate with frame,8 Module |
| 100 | Supply and fixing of modular switch one way 6 A white Active one module complete all as specified and as directed. |
| 101 | Supply and fixing in repair of socket 2M 6A-2/3 pin combined Active white complete all as specified and as directed. |
| 102 | Supply and fixing of modular fan step regulator,120 W-1 module complete all as specified and as directed. |
| 103 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 104 | S&F MCB,DB SPN 02 way in SS enclosure type complete all as specified and as directed. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule |
| 105 | Supply and fix for MCB SPN 230 V, 32 Amps with breaking capacity 10KA C curve complete all as specified and as directed. |
| 106 | Supply and fix BLDC ceiling fan 230 V, 1200mm smart saver-50 of complete all as specified and as directed. |
| 107 | Supply and fix 4mm thick sheet glass, ordinary quality and glazing with rubber beading around the glass, in squares n exc 0.50 sqm in each pane with dark colour sun film coating in glazing area complete all as specified and as directed. |
| 108 | S &F Hangers 6 mm dia. G.I. (upto 1200mm length) (size of grid 605 x 605mm)adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 109 | M &L Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) complete all as specified and as directed. |
| 110 | S & F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. |
| 111 | M & L for 2 coat of plastic emulsion over a coat of primer after preparation on new or previously untreated surfaces of any description over 10cm girth or width, not otherwise described complete all as specified and as directed. |
| 112 | Surface dressing n exc 15 cm deep complete all as specified and directed. |
| 113 | Material and labour for hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc 150 mm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 114 | M & L for Cement concrete 1:4:8 in type D2 40 mm graded aggregate in base subbase with thickness 75 mm, etc as specified and directed. |
| 115 | M & L for Cement concrete 1:2:4 in type B0 12.5 mm graded aggregate in floor with thickness 40 mm, etc as specified and directed. |
| 116 | Material and labour for 20 mm thick CM 1:4 Screed bed or bedding layer of mortar for laying floor finishes all as specified and as directed. |
| 117 | M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floor with grey pigments with screed bed of 15 mm thick in 1:4 CM below the tile as specified and directed. |
| 118 | M & L for Plain cement concrete in foundation of type B2 1:2:4 with 40 mm graded aggregate as specified and directed. |
| 119 | S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment in Fe-410 W Gd E-250 complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender