Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56841034

Tender For Repair Replacement And Cleaning Of Sewage Line, Manholes, Septic Tank, Soakage Well In The Area Of Age B/R-Ii Under Ge (East) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
49 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
9 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Replacement And Cleaning Of Sewage Line, Manholes, Septic Tank, Soakage Well In The Area Of Age B/R-Ii Under Ge (East) Delhi Cantt-10

BOQ

Name of Work:- REPAIR REPLACEMENT AND CLEANING OF SEWAGE LINE, MANHOLES, SEPTIC TANK, SOAKAGE WELL IN THE AREA OF AGE B/R-II UNDER GE (EAST) DELHI CANTT-10
Sl. No. Item Description
1Excavation in trenches not exc 1.5m wide and not exceeding 1.5 mtr in depth for foundation etc shaft, cesspits, manholes sewage line etc not exc. 10 Sqm on plan and getting out complete all as specified and directed.
2Description all as per item No 1 have in before but depth exceeding 1.5mts and not exc 3mtr all as specified and directed.
3Returning, filling in, trenches with soil in layers not exc 25 cm thick, watering and well ramming complete all as specified and directed.
4Removal of surplus soil to a distance not exc 50 mtr away & deposting where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
5Demolition and breaking up old unserviceable salt glazed stoneware pipe 150mm bore at any depth set in cement morter incl PCC bed complete all as specified and directed.
6Description all as per sl item No 5.00 above but 200mm dia.
7M&L for PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregates) bedding for sewage lines of 150mm bore incl packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
8Description all as per sl item No 7.00 above but for bed of sewage line of 200mm bore.
9Supply and fixed class SN-8, dia of pipe 150mm & thickness of pipe as specified in IS 16098 (Part-2):2013, clause 6.3.1 table no 5 structured wall polythelene piping system (pipe with online/offline coupler and elastomeric sealing ring) with non smooth external anular corrugated and smooth internal surface (double wall) for non pressure underground sewerage & drainage application polythylene piping fitted with help of coupler attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying at prescribed gradient, depth and alignment, testing the water tightness of the joint, ensuring the continuity tests of the specified pipe segments etc including all necessary fittings (cost of fittings, rubber rings, gaskets etc includded) complete all as specified and directed by Engineer-in-charge.
10Description all as per srl item No 9.00 above but 200 mm dia
11M&L for Cutting into existing manholes for connecting 150/200 mm bore of pipe new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified.
12Dismantling of brick work built in cement mortar of any description incl cleaning site & removing from MOD land complete all as specified and directed.
13M&L for brick work with sub-class 'B' bricks (old size)straight or curved on plan exceeding 6 mtrs mean readius built in CM 1:4 complete all as specified and directed.
14M&L for rendering 15mm thick in cement mortar 1:4 mixed with WPC as per manufacturer's instructions to fair faces of brick or conrete surfaces finished even and fair complete all as specified and directed. Note:-WPC shall be measured & paid for speparately as supply only.
15Supply only integral water proofing compound ISI marked complete all as specified and directed.
16Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc
17M&L for rendering 15mm thick external ready mix plaster (as per manufacture' instruction) on brick wall or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
18M&L for preparation new surfaces of walls and cornices spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying two coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
19S&F in repair Precast Cement concrete (M-30 Grade of concrete) manhole / drain cover of size 1200/1000mm x 500mm x 70mm thick srounded with steel strip 70x1.25mm Reinforced as per manufacturer's design in Munufactured proccess laid over drain/MH inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge.
20S&F in repair Precast Cement concrete (M-30 Grade of concrete) manhole/drain cover of size 600mm dia & 75m thick with srounded with steel strip 75x1.25mm Reinforced as per manufacturer's design in Munufactured proccess laid over drain/MH inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge.
21S&F in repair Precast Cement concrete (M-30 Grade of concrete) GT cover of size 500mmx400mm x50mm thick or as per site requirement with one handle & 150mm dia notch in cover inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information
22S&F in repair Precast Cement concrete (M-30 Grade of concrete) GT cover of size 500mmx400mm x50mm thick or as per site requirement with one handle & 150mm dia notch in cover inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56841034
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Replacement And Cleaning Of Sewage Line, Manholes, Septic Tank, Soakage Well In The Area Of Age B/R-Ii Under Ge (East) Delhi Cantt-10
Basic Detail
Tender No GE/DE-102/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 04 Aug 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
BOQ_876901.xls
c8a16f84-bdd4-4b1d-b67a-08dc2e39c60f.html
Tender102.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_876901.xls

html

c8a16f84-bdd4-4b1d-b67a-08dc2e39c60f.html

pdf

Tender102.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders