Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56841023

Tender For Repair/Maint Of Ci/Di/Gi/Ppr Pipeline At Md Accns And Klps Outside Moat Area At Vijay Durg Under Ge(Fw) Kolkata

Issued by Statutory Bodies & Commissions/Committees · Kolkata, West Bengal
Tender Value
35.50 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
9 days left
EMD
71000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Ci/Di/Gi/Ppr Pipeline At Md Accns And Klps Outside Moat Area At Vijay Durg Under Ge(Fw) Kolkata

BOQ

Name of Work:- REPAIR/MAINT OF CI/DI/GI/PPR PIPELINE AT MD ACCNs AND KLPs OUTSIDE MOAT AREA AT VIJAY DURG UNDER GE(FW) KOLKATA
Sl. No. Item Description
1Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., forming bottom surfaces to required slope/gradient where pipe are laid and getting out in any type of soil complete all as specified and directed.
2Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
3Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
4Taking up / down 100 mm bore, GI water tubing and connection from trenches/ walls / floors (of any location) for replacement / re-use in old / new location as directed by the Engr-in-Charge. (Note: Necessary earthwork, if any , will be measured and paid separately under relevant items)
5All as per Item No. 04 above but of size 80 mm bore
6All as per Item No. 04 above but of size 50 mm bore
7All as per Item No. 04 above but of size 40 mm bore
8All as per Item No. 04 above but of size 25 mm bore
9All as per Item No. 04 above but of size 20 mm bore
10All as per Item No. 04 above but of size 15 mm bore
11S&F, 15 mm bore steel water tubing, medium grade, ISI marked, galvanized, including all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., laid in trenches or fixed to walls and ceilings or concealed in walls, ducts/ceilings or laid in floors complete all as specified and directed.
12All as per item No 6.00 above but 20mm bore of pipe.
13All as per item No 6.00 above but 25mm bore of pipe.
14All as per item No 6.00 above but 40mm bore of pipe.
15All as per item No 6.00 above but 50mm bore of pipe.
16All as per item No 6.00 above but 80mm bore of pipe.
17All as per item No 6.00 above but 100mm bore of pipe.
18Relaying/Refixing 100 mm bore GI tubing and connections in new or old position after thoroughly cleaning, with new fittings, laid in trenches/ceiling complete all as specified and as directed by Engr-in-Charge. (Note : GI tubing obtained from item No 6 to 6.06 to be re-used. Necessary earth-work to be measured and paid separately under relevant items).
19All as per Item No. 7.00 above but of size 80 mm bore
20All as per Item No. 7.00 above but of size 50 mm bore
21All as per Item No. 7.00 above but of size 40 mm bore
22All as per Item No. 7.00 above but of size 25 mm bore
23All as per Item No. 7.00 above but of size 20 mm bore
24All as per Item No. 7.00 above but of size 15 mm bore
25Taking up /down CI/DI water mains and connections/fittings of any type from trenches /walls/floors/(or any other location) for replacement /reuse in old/new location/diversion by burning out /removing of lead joints/tyton joints/rubber gasket joint complete all as directed by the Engineer-in-Charge.
26Bore size 80 mm
27Bore size 100 mm
28Bore size 150 mm
29Bore size 200 mm
30Relaying of the following size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches as directed by Engr-in-Charge for the following size of pipes:- (NOTE: CI/DI water mains obtained from item No 8 to 8.04 be re-used. Lead joint/tyton rubber gasket joint/new specials will be measured and paid seperately under relevent item of this schedule)
31Bore size 80 mm
32Bore size 100 mm
33Bore size 150 mm
34Bore size 200 mm
35Supply, laying and testing the following size CI water mains with spigot and socket ends, centrifugally cast of class 'A' in any length, laid in trenches/walls/floors/ceilings with new fittings as directed by Engr-in-Charge. (Note: Lead joint/tyton rubber gasket joint/new CI/DI specials will be measured and paid seperately under relevent item of this schedule)
36Bore size 80 mm
37Bore size 100 mm
38Bore size 150 mm
39Bore size 200 mm
40Supply, laying and testing the following size CI water mains with flanged ends, centrifugally cast of class 'A' in any length, laid in trenches/walls/floors/ceilings with new fittings as directed by Engr-in-Charge. (Note: Lead joint/tyton rubber gasket joint/new CI/DI specials will be measured and paid seperately under relevent item of this schedule)
41Bore size 80 mm
42Bore size 100 mm
43Bore size 150 mm
44Bore size 200 mm
45Supply, laying, jointing and testing 80mm bore Ductile Iron pipes with spigot and socketed ends, centrifugally cast, class K-9, conforming to IS-8329 in any length with blue epoxy coating laid in trenches complete including jointing by using elastomeric gasket all as specified and directed.
46All as per item No 12.00 above but 100mm bore of pipe.
47All as per item No 12.00 above but 150mm bore of pipe.
48All as per item No 12.00 above but 200mm bore of pipe.
49M&L, DI fittings for pipes upto 200mm bore such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. 'Y' junction, double socket flange branch, cross ,open flange(all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
50M&L, Cast iron fittings, Bends (any type, radius andangle) tapers any type,(straight, bend, increasing,decreasing or double socket ,collar, etc.)Tee pieces single branch. \\"Y\\"junction, double branch, cross(all sockets or socket and spigot)collars, caps and plugs complete all as specified and as directed.
51Material and labour for run lead joint (using old retrieved lead) for 80 mm bore cast iron water mains complete all as specified and as directed by the Engineer-in-Charge.(Note: New lead required for jointing of pipes shall be measured and paid seperately)
52All as per Item No. 58 above but of size 100 mm bore
53All as per Item No. 58 above but of size 150 mm bore
54All as per Item No. 58 above but of size 200 mm bore
55Supply only lead conforming to IS782 , complete as all specified and as directed.
56Taking out suction pipe of 200mm bore with defective CI foot valve/stainer of 200 mm dia and replace foot valve (ISI marked) including necessary nut, bolt, washers and cutting threading of CI/DI/GI pipe if required and lowering in the sump complete all as directed by the Engr-in-Charge.
57All as per Item No. 20.00 above but of size 150 mm bore
58All as per Item No. 20.00 above but of size 100 mm bore
59Supply, install, test and commissioning of 80mm bore CI Sluice Valve in repairs, Class PN-1.6, both ends flanged and drilled type with brass spindle including wheel, suitable rubber gasket for flanged joints, ISI marked, including provision of necessary jointing materials nuts and bolts, washers etc., complete all as specified and directed.
60All as per item 21.00 above but 100mm bore Sluice Valve.
61All as per item 21.00 above but 150mm bore Sluice Valve.
62All as per item 21.00 above but 200mm bore Sluice Valve.
63S&F in repairs, 80 mm dia Butterfly valve in CI body with stainless steel disc & stem, nitrile/EPDM liner, lever operated, ISI marked including bolts, nuts and wshers complete all as specified and as directed.
64All as per item 22.00 above but 100mm bore Butterfly Valve.
65All as per item 22.00 above but 150mm bore Butterfly Valve.
66All as per item 22.00 bove but 200mm bore Butterfly Valve.
67S&F in repairs, 80mm bore, PN-1.0 Non Return valve in CI body with bypass arrangement, ISI marked including bolts, nuts & washers and packing material complete all as specified and as directed.
68All as per item 23.00 above but 100mm bore Non Return Valve.
69All as per item 23.00 above but 150mm bore Non Return Valve.
70All as per item 23.00 above but 200mm bore Non Return Valve.
71S&F in repairs, 20mm dia Gun metal, globe or gate valves with iron wheel head, ISI marked screwed both ends for iron/GI pipe and fixed complete all as specified and as directed.
72All as per item 24.00 above but 25mm dia globe or gate valve.
73All as per item 24.00 above but 40mm dia globe or gate valve.
74All as per item 24.00 above but 50mm dia globe or gate valve.
75Supply and fixing in repair 100 mm bore CI butterfly valve, conforming to BS-5155, gear operated with necessary rubber gaskets, nuts and bolts and washers of suitable size as directed by the Engineer-in-Charge.
76All as per Item 25.00 above but of size 150 mm bore
77All as per Item 25.00 above but of size 200 mm bore
78Construction of valve chamber of min size 0.9m x0.9m x0.80 m internal size suitable for housing sluice valve / gate valve etc with PCC 1:4:8 type D2 for foundation 15mm thick with an offset of 5 cm on all sides, brick work in CM 1:4 230mm thick rendering in CM 1:4, 15mm thick, 5 cm thick & 230mm wide PCC 1:2:4 type B1 coping over brick work all around including provision of MS angle iron frame 40 x 40 x 6 mm embedded in concrete with suitable hinges 5 mm thick MS sheet cover and locking arrangements including two coats of synthetic enamel paint over a coat of red oxide metal primer on exposed steel surfaces including demolition of existing damaged valve chamber and necessary excavation & earth work etc all as specified and directed.
79Cutting of road/hard standing not exc 30cm in width and not exc 60cm in depth for removal/laying of water tubing including returning filling and making good the disturbed surfaces using PCC 1:2:4 type B1 using 20mm graded stone aggregate on top 100mm layer and fair fininshing the surface without using any extra cement all as specified and directed.
80Taking down UP/down Unserviceable / rust valve pit cover and frame / support or platform etc of any size/thickness and supply, fabrication and fixing of framed bracket, made of mild steel plate/flat/angle iron (of required size ), cut to shape and size,as in valve pit cover /frame/support or platform including two coats of black bituminous paint over a coat of red oxide zinc chome primer complete all as directed .
81Cutting of existing CI/DI pipe to required length for insertion of Tee/Valves/Taking branch connection /addn/altn/etc complete all as specified and as directed by the Engineer- in -Charge for the following size of pipes :-
82100 mm bore
83150 mm bore
84200mm bore
85Supply, laying and testing of 110 mm outer dia, 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 UV PN 16 stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed by Engr-in-Charge.
86All as per Item 30.00 above but of 90 mm outer dia
87All as per Item 30.00 above but of 63 mm outer dia
88All as per Item 30.00 above but of 50 mm outer dia
89All as per Item 30.00 above but of 40 mm outer dia
90All as per Item 30.00 above but of 32 mm outer dia
91All as per Item 30.00 above but of 25 mm outer dia
92All as per Item 30.00 above but of 25 mm outer dia
93S&F of Plain elbow 90 degree of dia 32 mm along with making arramgements
94S&F of Plain elbow 90 degree of dia 40 mm along with making arramgements
95S&F of Plain elbow 90 degree of dia 50 mm along with making arramgements
96S&F of Plain elbow 90 degree of dia 63 mm along with making arramgements
97S&F of Plain elbow 90 degree of dia 90 mm along with making arramgements
98S&F of Plain elbow 90 degree of dia 110 mm along with making arramgements
99S&F of equal tee of dia 32 mm along with making arramgements
100S&F of equal tee of dia 40 mm along with making arramgements
101S&F of equal tee of dia 50 mm along with making arramgements
102S&F of equal tee of dia 63 mm along with making arramgements
103S&F of equal tee of dia 90 mm along with making arramgements
104S&F of equal tee of dia 110 mm along with making arramgements
105S&F of Clamps of size 63 mm dia complete all as specified and directed.
106S&F of Clamps of size 50 mm dia. complete all as specified and directed.
107S&F of Clamps of size 40 mm dia. complete all as specified and directed.
108S&F of Clamps of size 32 mm dia. complete all as specified and directed.
109S&F of Clamps of size 25 mm dia. complete all as specified and directed.
110S&F 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
111All as per above item No 48 here-in-before but 25 mm bore Ball brass valves.
112All as per above item No 48 here-in-before but 40 mm bore Ball brass valves.
113Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and directed.
114Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and directed.
115M&L Brick Work with Flyash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
116M&L Plain Cement Concrete type C2 (1:3:6) using 40 mm graded aggregate) in Foundation, Filling and Mass Concrete, complete all as specified and as directed.
117M & L rendering 10 mm thick on brick or concrete surface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed. Please Enable Macros to View BoQ information
118M & L rendering 10 mm thick on brick or concrete surface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56841023
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35.50 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Ci/Di/Gi/Ppr Pipeline At Md Accns And Klps Outside Moat Area At Vijay Durg Under Ge(Fw) Kolkata
Basic Detail
Tender No 8631/E8
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 04 Aug 2026
Submission Date 25 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 35.50 Lakhs
Tender Fee 500
EMD 71000
Exemption Not Available
Document List
924a7941-7fa6-4c14-bac5-fbc009d72633.html
BOQ_876926.xls
TENDER8631REJOIN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

924a7941-7fa6-4c14-bac5-fbc009d72633.html

xls

BOQ_876926.xls

pdf

TENDER8631REJOIN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders