Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #56841000

Tender For Repair/Replacement Of Roof, Water Proofing Treatment, Roof Sheets, Chajja, Grit Wash Plaster & Other Connected Works In Airmen Mess, Sncos Mess, Dsc Line, Dsc Md Accn, Madhur Milan, Offrs Mess & Offrs Living Accn Area Of 13 Brd And 16 Brd

Issued by Statutory Bodies & Commissions/Committees · Gurgaon, Haryana
Tender Value
48 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
5 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Roof, Water Proofing Treatment, Roof Sheets, Chajja, Grit Wash Plaster & Other Connected Works In Airmen Mess, Sncos Mess, Dsc Line, Dsc Md Accn, Madhur Milan, Offrs Mess & Offrs Living Accn Area Of 13 Brd And 16 Brd At Af Stn Palam Under Ge (Af) Gurgaon No. 01

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-Aug-2026

BOQ

Name of Work:- Repair/Replacement of roof, water proofing treatment, roof sheets, chajja, grit wash plaster & other connected works in Airmen mess, SNCOs Mess, DSC Line, DSC Md Accn, Madhur Milan, Offrs Mess & Offrs Living Accn area of 13 BRD and 16 BRD at AF Stn Palam under GE (AF) Gurgaon No. 01
Sl. No. Item Description
1Schedule-A
2Taking down complete existing water proofing treatment/brick tiles of any description over roof slabs / parapets etc including grass, trees treating with chemical and cleaning the surface and removal out side of MoD land complete all as specified and as directed.Note :Taking down earthig strips and solar panel wires/ PVC Water Tanks of any size/ GI/CPVC/UPVC Pipe from roof and re-fixing on the same position after APP laying is deemed to be inclusive of rate quoted by the contractor.
3Demolition of existing old padding concrete of any thickness of existing water proofing treatment over the RCC slab other than beams, chajjas, staircase etc by chipping of with proper tools viz chiesel and with applying reasonable force so as to avoid any damages to existing RCC roof slab complete as directed by Engineer-in-charge.
4Taking down cement plaster, any description on brick, concrete or stone walls/ceiling/facias/Chajjas including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off out side of MoD land all as specified and directed by Engineer-in-charge.
5M&L for Cutting grooves as V type in brick wall/ slab, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and directed by Engr-in-Charge.
6M&L for providing PCC 1:2:4 type B0 using 12.5mm graded stone aggregates avg Th 40 mm as in levelling/ padding course on roof slab, projections on similar surfaces existing with slope, making the surface even and smooth without using extra cement.
7M&L for cement concrete, type B-1, 1:2:4 (20 mm graded stone aggregate) in roof kerbs or mud stops, using rounded or chamfered on edges or making slop on roof for padding, complete all as specified and directed by Engr-in-Charge.
8M&L 100 mm thick PCC type B2, (1:2:4) using 40mm graded stone aggregate as in flooring, Tank Stagging complete fair finished even and smooth without using extra cement
9M&L for 15 mm thick cement plastering in CM 1:4 on brick/ concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement (Including 04 Story building), complete all as specified and directed by Engr-in-Charge. (Note :- Water proofing compound shall be measured & paid separately).
10Supply only liquid water proofing compound.
11M&L water proofing treatment on roof/parapet/Chajjas on horizontal or vertical surfaces consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.40 Kg/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified.(c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/ sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.
12M&L for applying two coats of aluminium paint on the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge.
13Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer -in-Charge Please Enable Macros to View BoQ information
14Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer -in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56841000
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Roof, Water Proofing Treatment, Roof Sheets, Chajja, Grit Wash Plaster & Other Connected Works In Airmen Mess, Sncos Mess, Dsc Line, Dsc Md Accn, Madhur Milan, Offrs Mess & Offrs Living Accn Area Of 13 Brd And 16 Brd At Af Stn Palam Under Ge (Af) Gurgaon No. 01
Basic Detail
Tender No GE(AF) No 1/GUR-35/2026-27
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 18 Aug 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 48 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
38396596-f16f-4995-928e-9fe7a439a014.html
BOQ_876349.xls
TenderDocument35.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

38396596-f16f-4995-928e-9fe7a439a014.html

xls

BOQ_876349.xls

pdf

TenderDocument35.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders