Tender For Rep/Maint Flushing Of Submersible Pump Sets, Electric Control Panels, Dg Protection System At Rushikuliya Pump House And Rep/Repl Of Flame Proof Wiring, Water & Flame Proof Light Fittings & Fixtures At Amn Dump, Supply Depot Mag Guards And
Tender Overview
Project Description
Tender for Rep/Maint Flushing Of Submersible Pump Sets, Electric Control Panels, Dg Protection System At Rushikuliya Pump House And Rep/Repl Of Flame Proof Wiring, Water & Flame Proof Light Fittings & Fixtures At Amn Dump, Supply Depot Mag Guards And Connected Items Under Ge (I) Gos
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting the electric connection and taking out the submersible pump set from bore / open well of any capacity including GI column pipe complete and lowering down repaired motor with column pipe, welding joints and connecting electrical connection as directed and transportation of submersible pump set upto 15 HP 3 phase from pump house to any location in GMS area to contractors work shop repaired pump set for relowering, dismantling and carrying out necessary repairs complete all as specified and directed |
| 2 | Dismantling of submersible motor 7.5 HP 3 phase from pump house at any location in GMS area under AGE E/M GOS Yard, transporting to contractors workshop, dismantling and carrying out necessary repairs/replacement of motor as per the following :- (a) Cutting out existing winding of stator of submersible motor of any make and rewinding with same size of copper winding wire as existing as directed by the EIC. (b) Straightening the slot of starter of submersible motor of any make (c) Replacement of thrust washer and bearing complete of submersible motor of any make. (d) Replacement of worn-out bushes of submersible motor as per manufacturers design and specification. (e) Replacement of sand guard (f) Providing of sleeves in end plate of submersible motor (g) Replacement of cable gormmet (h) Replacement of water seal (i) Replacement of studs with nuts (j) Lathe work of motor shaft, turning to bring it to original size and shape and plastering of shaft of submersible motor for smooth functioning on described amps |
| 3 | Replacement of impeller upto 7.5 HP submersible pump set |
| 4 | Replacement of old rusted GI Column Pipe heavy grade of size 50 mm dia in pieces of 3.3 metre long , lathe m/c threaded both ends in the bore/open wells complete all as specified and directed. |
| 5 | Replacement of old rusted heavy grade GI socket of size 50 mm dia complete all as specified and directed by EIC. |
| 6 | S&F in repair PVC insulated submerssible cable water proof flate type 3 core with standed copper conductor cable, 4 Sqmm, 1100 volts grade including cable lugs/joints, connection to submerssible motor and other end to aluminium armoured cable including jointing complete as directed. |
| 7 | S&F in repair HDPE Borecaps of size 200/250mm dia complete all as directed by Engineer-in-Charge |
| 8 | S&F in repair of steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia(multi wire steenless steel) for holding of submersible pump motor set all as directed by Engineer-in-Charge. |
| 9 | Dismantling complete openwell submersible pump of capacity 60 HP and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers. replacement of gunmetal bush bearing and gland packing of pump set. and refitting the same after the repair/replacement duly all as specified and tested for smooth functioning of capacity 60 HP |
| 10 | Dismantling the power supply of open well submersible pump set of 60 HP including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including motor terminals plate/cable ducts complete of capacity 60 HP including painting complete all as directed. |
| 11 | S&F in repair Star Detla Timer 0-30 Seconds duration |
| 12 | Supply and fix in replacement of MCB TP 40 amps, |
| 13 | Supply and fix in replacement gun metal NRV of size 50 mm dia. |
| 14 | Supply and fix in replacement of low/high voltage monitoring device 440 volts, 3 phase |
| 15 | Supply and fix in replacement of phase monitoring device 440 volts, 3 phase . |
| 16 | Supply & fix in replacement of Dry run & over load protection with phase failure relay alongwith suitable CTS |
| 17 | Supply and fix in replacement of electronic adjustable cyclic timer |
| 18 | Supply and fix in replacement of DOL starter for submersible pump set type MN-16 and relay range 9-15 amps with contactor complete. |
| 19 | Supply and replacement contactor 16 /18 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ |
| 20 | All as per Item No 19 above but 40/50 Amps capacity |
| 21 | Supply and fix in replacement of MCCB 4 Pole , 415 V , 250 Amps with breaking capacity 36 KA panel mounting type , AC |
| 22 | Supply and fix in replacement of MCCB 4 pole , 415 V , fixed type 125 Amp panel mounting type ,with breaking capacity 16 KA AC, |
| 23 | Supply and fix in replacement of MCCB 4 pole , 415 V , fixed type 63 Amp panel mounting type ,with breaking capacity 16 KA AC, |
| 24 | Flushing the bore well for flushing of silt, fine sand etc by air compressor of suitable capacity and pumping out turbidity till obtaining clear water all as directed and as per site requirement. |
| 25 | Supply and fix in replacement Voltmeter digital type (0-500V) |
| 26 | Supply and fix in replacement Ammeter digital type (0- 100 Amps) |
| 27 | Supply and fix double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified and directed |
| 28 | Material and labour for filling the road / hard standings cut for laying cable with PCC 1:2:4, type B2, using 40 mm graded stone aggregate and finishing the surface even and smooth without using extra cement all as specified and directed. |
| 29 | M & L GI tubing light grade 40mm borewith all fitting(ISI marked) for protection of cable fixed to pole/wall / laid under floor or road including necessary joints and clamps complete all as specified and directed |
| 30 | Boring of holes horizontally for laying of 40mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 31 | Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 10 Sqmm 4 Core, including taking down old, complete all as specified and directed. |
| 32 | All as per item No 31 above, but 16 Sqmm 4 Core. |
| 33 | Supply and Fix stainless Steel nut and bolt 10 mm to 16 mm ,40 mm long complete all as specified and as directed |
| 34 | Supply only copper lugs 10 to 35 sqmm for existing panel board complete all as specified and as directed |
| 35 | Supply and fix Gland rope of size 10 mm to 15 mm for various motor complete all as specified and as directed |
| 36 | Supply and replacement contactor MNX -18 ,50/60 Hz 55 degree centrigate Amps capacity , AC 3 phase 415 Volts, 50 HZ |
| 37 | Supply, and Fix 16 sqmm single Core, copper conductor for existing panel to smooth functioning of motor and pump including taking down old, complete all as specified and directed. |
| 38 | Supply, and Fix 35 sqmm single Core, copper conductor for existing panel to smooth functioning of motor and pump including taking down old, complete all as specified and directed. |
| 39 | Supply and Fixing of Change over switch with encloser of capacity 250 Amp ,3 Phase ,4 Pole complete including taking out of old /burn U/S changeover.complete all as specified . |
| 40 | Supply and fixing street light fitting LED type 25 Watt new generation in aluminium PDC housing, toughened glasscover with IP 66 protection complete in all respect with GI tubing 25mm/40mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of flexible aluminium/copper conductor of size 1.5 sq mm cable from fitting to junction box/conductor to street light as suitable on site, testing & commissioning complete all as specified and directed. |
| 41 | Supply and fixing LED flood light 200 watt Lumos II new generation LED with high luminous efficacy of 120 lm/w protected to IP-66 with front toughened glass complte in all respect with GI tubing reqd in site, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of suitable flexible aluminium/copper conductor of size 2.5 sq mm or fixed in appropriate size of PCC block made with PCC 1:3:6 with fixing arrangement suitable on site, testing & commissioning complete incl taking down old unsv any type and make all as specified and directed. |
| 42 | Taking Down old unserviceable GI/PPR pipes and S&F 3-layer PP-R polypropylene random copolymer concealed pipe (PN 16/SDR 7.4) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings, floors or in trenches etc of size 63 mm OD complete all as specified and directed. |
| 43 | All as per Item No. 42 above but of size 32 mm OD. |
| 44 | S&F in repair of PP-R gate valves(brass inlet) as per requirement of size 63 mm OD complete all as specified and directed. Make : SFMC or equivalent in approved by E-in-C |
| 45 | All as per Item No. 44 above but 32 mm OD. |
| 46 | Excavation of trenches in any type of soil n.exc 1.5 M wide and n.exc 1.5 M in depth for taking out/laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and as directed. |
| 47 | Returning, filling in and including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed |
| 48 | Removing excavated surplus materials to a distance not exceeding 50 Mtrs and deposited where directed at a level not exceeding 1.5 Mtr. Above starting point complete all as specified and directed. |
| 49 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 50 | Supply and laying bricks common burnt clay flyash building bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and directed. Please Enable Macros to View BoQ information |
| 51 | Supply and laying bricks common burnt clay flyash building bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender