Tender For Name Of Work :- Rewinding Of 3300V Ht Motor 2 Nos At Ps Ii And Servicing And Overhauling Of 3300V Ht Motor 3 Nos At Ps Iii And Ps Iv Of Kanwarsain Lift Scheme For The Year 2026-27. (Item No 2)
Tender Value
35.41 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
8 days left
EMD
70824
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Name Of Work :- Rewinding Of 3300V Ht Motor 2 Nos At Ps Ii And Servicing And Overhauling Of 3300V Ht Motor 3 Nos At Ps Iii And Ps Iv Of Kanwarsain Lift Scheme For The Year 2026-27. (Item No 2)
BOQ
| Sl. No. | Item Description |
| 1 | Section 1: Servicing of motor at PS III and PS IV |
| 2 | Transportation charges for 3.3 KV HT Motor repair/servicing/rewinding from site to workshop & from workshop to site 150 KW-300 KW |
| 3 | Transportation charges for 3.3 KV HT Motor repair/servicing/rewinding from site to workshop & from workshop to site 301 KW-700KW |
| 4 | P&F of BTD of 3.3 KV HT induction motor |
| 5 | P&F of RTD of 3.3 KV HT induction motor |
| 6 | P&F of Insulator/Bushing/Lugs of 3.3 KV HT induction motor |
| 7 | P&F of bearing temperature meter for 3.3 KV HT induction motor (130 KW-670 KW) |
| 8 | P&F of grease pipe for DE side of 3.3 KV HT induction motor |
| 9 | P&F of grease pipe for NDE side of 3.3 KV HT induction motor |
| 10 | P&F of Stator lead per lead (approx 2.5 Meter. length) of 3.3 KV HT induction motor 150KW-300 KW |
| 11 | P&F of Stator lead per lead (approx 2.5 Meter. length) of 3.3 KV HT induction motor 301KW-700 KW |
| 12 | Labour Work :- Servicing of 3.3 KV Vertical squirrel cage three phase induction HT motor carrying out minor repair of the coils & insulation of the stator/rotor. Decarburization / cleaning / heating /varnishing / baking of stator winding for protection against moisture, dirt/dust and rotor lamination for any hot spot after conducting magnetic flux loop test .Repair of damaged insulation of HT leads &. re-enforcing loose lugs. Checking/regreasing of bearings of DE & NDE side & Fixing of new bearings if required with making of bearing hub sheet, Checking the Shaft trueness, Checking and repair work of end shield cover, Repair/ replacement of RTD/ BTD/ space heater & missing & broken wedges from new magnetic wedges, cleaning & leakage repair of water radiator tubes, painting of motor, Final testing of Motor like following tests as IR Value test, Resistance test, inductance test & submit the test report. Testing, Trial of motor on site (supply of Bearing, RTD,BTD,space heater,temprature meter not in scope of work) 132 KW |
| 13 | Labour Work :- Servicing of 3.3 KV Vertical squirrel cage three phase induction HT motor carrying out minor repair of the coils & insulation of the stator/rotor. Decarburization / cleaning / heating /varnishing / baking of stator winding for protection against moisture, dirt/dust and rotor lamination for any hot spot after conducting magnetic flux loop test .Repair of damaged insulation of HT leads &. re-enforcing loose lugs. Checking/regreasing of bearings of DE & NDE side & Fixing of new bearings if required with making of bearing hub sheet, Checking the Shaft trueness,Checking and repair work of end shield cover, Repair/ replacement of RTD/ BTD/ space heater & missing & broken wedges from new magnetic wedges, cleaning & leakage repair of water radiator tubes, painting of motor, Final testing of Motor like following tests as IR Value test, Resistance test, inductance test & submit the test report. Testing, Trial of motor on site (supply of Bearing, RTD,BTD,space heater,temprature meter not in scope of work) 250 KW |
| 14 | Labour Work :- Servicing of 3.3 KV Vertical squirrel cage three phase induction HT motor carrying out minor repair of the coils & insulation of the stator/rotor. Decarburization / cleaning / heating /varnishing / baking of stator winding for protection against moisture, dirt/dust and rotor lamination for any hot spot after conducting magnetic flux loop test .Repair of damaged insulation of HT leads &. re-enforcing loose lugs. Checking/regreasing of bearings of DE & NDE side & Fixing of new bearings if required with making of bearing hub sheet, Checking the Shaft trueness,Checking and repair work of end shield cover, Repair/ replacement of RTD/ BTD/ space heater & missing & broken wedges from new magnetic wedges, cleaning & leakage repair of water radiator tubes, painting of motor, Final testing of Motor like following tests as IR Value test, Resistance test, inductance test & submit the test report. Testing, Trial of motor on site (supply of Bearing, RTD,BTD,space heater,temprature meter not in scope of work) 320 KW |
| 15 | Section 2: Rewinding of 270 KW motor at PS II Malkisar |
| 16 | Rewinding of 3.3 KV HT induction Motor stator with Global VPI system , testing of motor at test bench, testing and trial of motor at site. Scrap will be retained by firm & rates are inclusive of scrap generated in rewinding. 270 KW |
| 17 | Re-barring/ Rewinding of the rotor of 3.3 KV Vertical squirrel cage three phase induction HT motor 270 KW |
| 18 | Transportation charges for 3.3 KV HT Motor repair/servicing/rewinding from site to workshop & from workshop to site 150 KW-300 KW |
| 19 | P&F of Stator lead per lead (approx 2.5 Meter. length) of 3.3 KV HT induction motor 150 KW-300 KW |
| 20 | P&F of Insulator/Bushing/Lugs of 3.3 KV HT induction motor |
| 21 | P&F of bearing temperature meter for 3.3 KV HT induction motor (130 KW-670 KW) |
| 22 | GST @ 18% ( 9% CGST+ 9% SGST) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender