Supply Of ENDOTRACHEAL TUBE FLEXOMETALIC/REINFORCED SIZE / ENDOTRACHEAL TUBE CUFFED SIZE
Tender Overview
Project Description
Supply Of endotracheal tube flexometalic/reinforced size / endotracheal tube cuffed size , srphc82201390-endotracheal tube flexometalic/reinforced size:8.5mm id. single use, colo r coded for easy identification of ports, balloons and 15mm connectors. low pressure / high volume cuffs and radio opaque stripe , sterile. should have good strength metal spirals embedded in wall o f the tube.should have murphy eye prefrably. ] , srphc82201295-endotracheal tube cuffed size:5.5 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201300-endotracheal tube cuffed size:6.0 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201305-endotracheal tube cuffed size:6.5 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201310-endotracheal tube cuffed size:7.0 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201315-endotracheal tube cuffed size:7.5 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201280-endotracheal tube cuffed size:4.0 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201285-endotracheal tube cuffed size:4.5 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201290-endotracheal tube cuffed size:5.0 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201320-endotracheal tube cuffed size:8.0 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201330-endotracheal tube cuffed size:9.0 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201325-endotracheal tube cuffed size:8.5 mm id.made of clear polyvinyl chloride (pvc). thermosensitive material that minimizes pressure on tracheal wall.radio opaque blue line for x-ray visualization.high volume, low pressure cuff. printed self sealing pilot balloon.the size of the tracheal tube internal diameter is printed on the pilot balloon. tube has a 15 mm connector enablin g connection to anaesthetic and ventilator breathing circuits. murphy eye. magill curve. sterile.single use. should conform to ce/ iso 5361:2023 (en) anesthetic and respiratory equipment - tr acheal tubes and connectors standards or equivalents ] , srphc82201400-endotracheal tube uncuffed size:2.5 id. designed for smaller airways. spe cial depth lines at the distal tip indicate the depth of intubation. the smooth, molded, gently cupped tip eases intubation, while the tube is desingned to soften at body temperature to conform to the ai rway anatomy. single - use , sterile. not made with natural rubber latex . ] , srphc82201410-endotracheal tube uncuffed size:3.5 id. designed for smaller airways. spe cial depth lines at the distal tip indicate the depth of intubation. the smooth, molded, gently cupped tip eases intubation, while the tube is desingned to soften at body temperature to conform to the ai rway anatomy. single - use , sterile. not made with natural rubber latex . ] , srphc82201360-endotracheal tube flexometalic/reinforced size:5.5mm id. single use, colo r coded for easy identification of ports, balloons and 15mm connectors. low pressure / high volume cuffs and radio opaque stripe , sterile. should have good strength metal spirals embedded in wall o f the tube.should have murphy eye prefrably. ] , srphc82201365-endotracheal tube flexometalic/reinforced size:6.0mm id. single use, colo r coded for easy identification of ports, balloons and 15mm connectors. low pressure / high volume cuffs and radio opaque stripe , sterile. should have good strength metal spirals embedded in wall o f the tube.should have murphy eye prefrably. ] , srphc82201375-endotracheal tube flexometalic/reinforced size:7.0mm id. single use, colo r coded for easy identification of ports, balloons and 15mm connectors. low pressure / high volume cuffs and radio opaque stripe , sterile. should have good strength metal spirals embedded in wall o f the tube.should have murphy eye prefrably. ] , srphc82201380-endotracheal tube flexometalic/reinforced size:7.5mm id. single use, colo r coded for easy identification of ports, balloons and 15mm connectors. low pressure / high volume cuffs and radio opaque stripe , sterile. should have good strength metal spirals embedded in wall o f the tube.should have murphy eye prefrably. ] , srphc82201385-endotracheal tube flexometalic/reinforced size:8.0mm id. single use, colo r coded for easy identification of ports, balloons and 15mm connectors. low pressure / high volume cuffs and radio opaque stripe , sterile. should have good strength metal spirals embedded in wall o f the tube.should have murphy eye prefrably. ]
BOQ
| Sl. No. | Item Description |
|---|---|
| 1 | SRPHC82201390-ENDOTRACHEAL TUBE FLEXOMETALIC/REINFORCED SIZE:8.5MM ID. SINGLE USE, COLO R CODED FOR EASY IDENTIFICATION OF PORTS, BALLOONS AND 15MM CONNECTORS. LOW PRESSURE / HIGH VOLUME CUFFS AND RADIO OPAQUE STRIPE , STERILE. SHOULD HAVE GOOD STRENGTH METAL SPIRALS EMBEDDED IN WALL O F THE TUBE.SHOULD HAVE MURPHY EYE PREFRABLY. ] |
| 2 | SRPHC82201295-ENDOTRACHEAL TUBE CUFFED SIZE:5.5 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 3 | SRPHC82201300-ENDOTRACHEAL TUBE CUFFED SIZE:6.0 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 4 | SRPHC82201305-ENDOTRACHEAL TUBE CUFFED SIZE:6.5 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 5 | SRPHC82201310-ENDOTRACHEAL TUBE CUFFED SIZE:7.0 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 6 | SRPHC82201315-ENDOTRACHEAL TUBE CUFFED SIZE:7.5 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 7 | SRPHC82201280-ENDOTRACHEAL TUBE CUFFED SIZE:4.0 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 8 | SRPHC82201285-ENDOTRACHEAL TUBE CUFFED SIZE:4.5 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 9 | SRPHC82201290-ENDOTRACHEAL TUBE CUFFED SIZE:5.0 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 10 | SRPHC82201320-ENDOTRACHEAL TUBE CUFFED SIZE:8.0 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 11 | SRPHC82201330-ENDOTRACHEAL TUBE CUFFED SIZE:9.0 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 12 | SRPHC82201325-ENDOTRACHEAL TUBE CUFFED SIZE:8.5 MM ID.MADE OF CLEAR POLYVINYL CHLORIDE (PVC). THERMOSENSITIVE MATERIAL THAT MINIMIZES PRESSURE ON TRACHEAL WALL.RADIO OPAQUE BLUE LINE FOR X-RAY VISUALIZATION.HIGH VOLUME, LOW PRESSURE CUFF. PRINTED SELF SEALING PILOT BALLOON.THE SIZE OF THE TRACHEAL TUBE INTERNAL DIAMETER IS PRINTED ON THE PILOT BALLOON. TUBE HAS A 15 MM CONNECTOR ENABLIN G CONNECTION TO ANAESTHETIC AND VENTILATOR BREATHING CIRCUITS. MURPHY EYE. MAGILL CURVE. STERILE.SINGLE USE. SHOULD CONFORM TO CE/ ISO 5361:2023 (EN) ANESTHETIC AND RESPIRATORY EQUIPMENT - TR ACHEAL TUBES AND CONNECTORS STANDARDS OR EQUIVALENTS ] |
| 13 | SRPHC82201400-ENDOTRACHEAL TUBE UNCUFFED SIZE:2.5 ID. DESIGNED FOR SMALLER AIRWAYS. SPE CIAL DEPTH LINES AT THE DISTAL TIP INDICATE THE DEPTH OF INTUBATION. THE SMOOTH, MOLDED, GENTLY CUPPED TIP EASES INTUBATION, WHILE THE TUBE IS DESINGNED TO SOFTEN AT BODY TEMPERATURE TO CONFORM TO THE AI RWAY ANATOMY. SINGLE - USE , STERILE. NOT MADE WITH NATURAL RUBBER LATEX . ] |
| 14 | SRPHC82201410-ENDOTRACHEAL TUBE UNCUFFED SIZE:3.5 ID. DESIGNED FOR SMALLER AIRWAYS. SPE CIAL DEPTH LINES AT THE DISTAL TIP INDICATE THE DEPTH OF INTUBATION. THE SMOOTH, MOLDED, GENTLY CUPPED TIP EASES INTUBATION, WHILE THE TUBE IS DESINGNED TO SOFTEN AT BODY TEMPERATURE TO CONFORM TO THE AI RWAY ANATOMY. SINGLE - USE , STERILE. NOT MADE WITH NATURAL RUBBER LATEX . ] |
| 15 | SRPHC82201360-ENDOTRACHEAL TUBE FLEXOMETALIC/REINFORCED SIZE:5.5MM ID. SINGLE USE, COLO R CODED FOR EASY IDENTIFICATION OF PORTS, BALLOONS AND 15MM CONNECTORS. LOW PRESSURE / HIGH VOLUME CUFFS AND RADIO OPAQUE STRIPE , STERILE. SHOULD HAVE GOOD STRENGTH METAL SPIRALS EMBEDDED IN WALL O F THE TUBE.SHOULD HAVE MURPHY EYE PREFRABLY. ] |
| 16 | SRPHC82201365-ENDOTRACHEAL TUBE FLEXOMETALIC/REINFORCED SIZE:6.0MM ID. SINGLE USE, COLO R CODED FOR EASY IDENTIFICATION OF PORTS, BALLOONS AND 15MM CONNECTORS. LOW PRESSURE / HIGH VOLUME CUFFS AND RADIO OPAQUE STRIPE , STERILE. SHOULD HAVE GOOD STRENGTH METAL SPIRALS EMBEDDED IN WALL O F THE TUBE.SHOULD HAVE MURPHY EYE PREFRABLY. ] |
| 17 | SRPHC82201375-ENDOTRACHEAL TUBE FLEXOMETALIC/REINFORCED SIZE:7.0MM ID. SINGLE USE, COLO R CODED FOR EASY IDENTIFICATION OF PORTS, BALLOONS AND 15MM CONNECTORS. LOW PRESSURE / HIGH VOLUME CUFFS AND RADIO OPAQUE STRIPE , STERILE. SHOULD HAVE GOOD STRENGTH METAL SPIRALS EMBEDDED IN WALL O F THE TUBE.SHOULD HAVE MURPHY EYE PREFRABLY. ] |
| 18 | SRPHC82201380-ENDOTRACHEAL TUBE FLEXOMETALIC/REINFORCED SIZE:7.5MM ID. SINGLE USE, COLO R CODED FOR EASY IDENTIFICATION OF PORTS, BALLOONS AND 15MM CONNECTORS. LOW PRESSURE / HIGH VOLUME CUFFS AND RADIO OPAQUE STRIPE , STERILE. SHOULD HAVE GOOD STRENGTH METAL SPIRALS EMBEDDED IN WALL O F THE TUBE.SHOULD HAVE MURPHY EYE PREFRABLY. ] |
| 19 | SRPHC82201385-ENDOTRACHEAL TUBE FLEXOMETALIC/REINFORCED SIZE:8.0MM ID. SINGLE USE, COLO R CODED FOR EASY IDENTIFICATION OF PORTS, BALLOONS AND 15MM CONNECTORS. LOW PRESSURE / HIGH VOLUME CUFFS AND RADIO OPAQUE STRIPE , STERILE. SHOULD HAVE GOOD STRENGTH METAL SPIRALS EMBEDDED IN WALL O F THE TUBE.SHOULD HAVE MURPHY EYE PREFRABLY. ] |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender