Tender For Repair / Maintenance Of Ceiling Fan, Exhaust Fan, Geyser & Day To Day Maintenance Of Age E/M Under (P) No 1 Jabalpur

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
49.99 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
1 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Ceiling Fan, Exhaust Fan, Geyser & Day To Day Maintenance Of Age E/M Under (P) No 1 Jabalpur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Aug-2026 ERRATA/ AMENDMENT TO TENDER DOCUMENTS AND BOQ Other 25-Aug-2026

BOQ

Name of Work:- REPAIR / MAINT OF CEILING FAN, EXHAUST FAN, GEYSER & DAY TO DAY MAINTENANCE OF AGE E/M UNDER (P) NO 1 JABALPUR
Sl. No. Item Description
1M & L for Taking down of ceiling fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,rubber reel ,clamps ,nuts and bolts including refixing and reconnection of ceiling fan with required size of 3 core copper conductor complete all as specified and directed.Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items) (2) Unsv Fan to be deposited to MES Yard/Store (E/M ) (3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site..
2M & L for Taking down of wall fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,rubber reel ,clamps ,nuts and bolts including refixing and reconnection of wall fan with required size of 3 core copper conductor complete all as specified and directed.Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items) (2) Unsv Fan to be deposited to MES Yard/Store (E/M ) (3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site..
3M & L for Taking down of Exhaust fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,clamps ,nuts and bolts including refixing and reconnection of ex fan with required size of 3 core copper conductor complete all as specified and directed.Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items) (2) Unsv Fan to be deposited to MES Yard/Store (E/M ) (3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site..
4M & L for comprehensive maintenance and overhauling of Geyser 25/50 Ltrs of any make and size including following works complete all as specified and directed.(a) Checking proper working of geysers.(b) Checking of PVC pipe/ safety valve/ heating element/ flange/ thermostat including replacement of unseviceable part (c) Checking of unserviceable bottom cover plate/ PVC pipe/ heating element/ thermostat / indicating lamp. (d) Cleaning of geyser 25/50 Ltr .
5Note for Sr 1 to 4 Above : 1.Contractor has to depute two team (comprising of 01x electrician & 01x helper in each Team) daily from commencement of work to till completion of work for day to day maintenance/ execution of work as per CA, who will report to JE E/M in MES YARD under AGE E/M . 2. Unserviceable parts to be measured & paid seperately under relevant item of Sch A. 3.All Tools & Plants incl transportation for shifting of geyser/Ceiling Fan/Exhaust Fan from user's accn to yard for repair/deposit and ladder provided to electrician at site by the contractor.
6M & L for Opening of ceiling fan of any make and any sweep for repair/ replacement of unserviceable parts complete all as specified and directed.Note: (1) Repair/ replacement of unserviceable parts to be measured & paid seperately in respective items.
7M & L for Opening of Exhaust fan of any make and upto 450 mm sweep size for repair/ replacement of unserviceable parts complete all as specified and directed.Note: (1) Repair/ replacement of unserviceable parts to be measured & paid seperately in respective items.
8Supply only ball bearing of 6201/120 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed.
9Supply only ball bearing of 6202/115 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed.
10Supply only ball bearing of 6203/117 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed.
11Supply only ball bearing of 6204/118 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed.
12Supply only condenser/capacitor 2.5 MFD of apporved make for ceiling fan complete all as specified and directed.
13Supply only condenser/capacitor 4.0 MFD for exhaust fan complete all as specified and directed.
14Supply only self lubricating bush of gun metal of same make for ceiling fan/exhaust fan complete all as specified and directed.
15Supply only shaft of approved quality for ceiling fan/Exhaust fan any make and type & size complete all as specified and directed.
16M&L for painting of ceiling fan including preparing the surface of body/blades of ceiling fan of any sweep and make and painting with 2 coats of synthetic enamel white paint and writing the MES No. with matching colour paint complete all as specified and directed.
17M&L for painting of exhaust fan including preparing the surface of body/blades/frame of exhaust fan of any sweep and make and painting with 2 coats of synthetic enamel Grey paint and writing the MES No. with black paint complete all as specified and as directed.
18Supply and hanging of ceiling fan, BEE 5 star rated high speed 1200 mm sweep(BLDC) complete with blades,downrods,and all accessories as required and provision of 3 core flexible copper conductor cable of suitable size and connecting up from existing ceiling rose to fan complete all as specified and directed.
19Supply and hanging of ceiling fan, BEE 5 star rated high speed 1400 mm sweep(BLDC) complete with blades,downrods,and all accessories as required and provision of 3 core flexible copper conductor cable of suitable size and connecting up from existing ceiling rose to fan complete all as specified and directed.
20S&F in replacement of Printed Circuit Board (PCB) of required make and programing for BLDC Fan 1200/1400 mm as per site required complete all as specified and as directed.
21S & F in replacement motor for fresh air fan size sweep upto 250 mm sweep, 230 v, 50 Hz complete with copper wire winding and connection complete all as specified and directed.
22S & F in replacement motor for fresh air fan size sweep from 300 upto 380 mm sweep, 230 v, 50 Hz complete with copper wire winding and connection complete all as specified and directed.
23S&F in replacement motor for Heavy duty exhaust fan size 450 mm sweep, 230v, 50 Hz complete with copper wire winding and connection complete all as specified and directed.
24S&F fresh air fan size sweep upto 250 mm sweep , complete with louvers including making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed.
25S&F fresh air fan size sweep 225 mm sweep, 230 v, 50 Hz , complete with louvers including making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed.
26S&F fresh air fan size sweep 300 mm sweep, 230 v, 50 Hz , complete with louvers including making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed.
27S & F Exhaust fan heavy duty size sweep 150 mm sweep, 230 v, 50 Hz , complete with louvers including making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed.
28S & F Exhaust fan heavy duty size sweep 225 mm sweep, 230 v, 50 Hz , complete with louvers including making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed
29S & F Exhaust fan heavy duty size sweep 300 mm sweep, 230 v, 50 Hz , complete with louvers including making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed
30Taking down carefully storage type water heater of any make and capacity from clamps/bolts including disconnection water and electric connections and refixing the same and connecting up after cleaning of geyser and repairs complete all as specified and directed.
31S&F Repair of inner flange of 25/50 Ltrs geysers and replacement of worn-out stud brazing with gas welding not exceeding 5mm thick complete all as specified and directed.
32Supply and fix in replacement geyser flange assembly (any make/type) copper alloy chromium plates suitable for 25 Ltrs capacity including rubber gasket, clamps and nuts/bolts etc complete all as specified and directed.
33~ditto~ all as item no 32 above, but for 50 Ltrs. complete all as specified and directed.
34Supply and fix and connecting heating element ( triangular or circular base type) 1.5 KW 230 volts suitable for 25 ltrs capacity geysers in replacement of old unserviceable heating element complete all as specified and directed.
35Supply and fix and connecting heating element ( triangular or circular base type) 2 KW, 230 volts suitable for 50 ltrs capacity geysers in replacement of old unserviceable heating element complete all as specified and directed.
36S&F in replacement thermostat of existing type/make complete or 25 Ltrs geyser complete all as specified and directed.
37S&F in replacement thermostat of existing type/make complete or 50 Ltrs geyser complete all as specified and directed.
38S&F in replacement indicating lamp, 230 volts as per site requirement complete all as specified and directed.
39S&F in replacement 15mm bore GI tube medium grade fixed to wall/geyser into short places including cutting, screwing, threading and all GI fittings (including union, socket if required) complete all as specified and directed.
40S&F in replacement geyser bottom cover complete including machine screws etc. as per original size and shape of any make of geyser 25 ltrs capacity complete all as specified and directed.
41~ditto~ all as item no 40 above, but for 50 ltrs. complete all as specified and directed.
42S&F brass chromium plated flexible pipe connection heavy duty IS Standard suitable for hot water supply with two Nos brass chromium plated union 450 mm long in replacement of PVC pipe connection complete all as specified and directed.
43S&F in replacement non return valve of 15mm size of brass for geyser complete all as specified and directed.
44M&L for painting of geyser with two coats of synthetic enamel white paint and writing the MES No.for 25/50 ltrs capacity geyser of any make and type complete all as specified and directed.
45S&F in replacement stop valve cast copper alloy 15mm bore a inlet or outlet connection of geysers complete all as specified and directed.
46S&F in replacement PVC insulated over all PVC flexible sheathed three core copper cable of size 2.5 sqmm including disconnection of old cable complete all as specified and directed.
47S&F Pressure release valve suitable for 25/50 ltrs any make any type of geyser complete in replacement of dead valve complete all as specified and directed.
48Removing old glass wool for the geysers and providing new glass wool of equal thickness for 25/50 Ltrs complete all as specified and directed.
49S&F three pin top 15 Amp 240 volts complete all as specified and directed
50S&F Top for earth plug socket 20 Amps AC 240 Volts complete all as specified and directed.
51S&F the safety valve suitable for geyser 25/50 litres complete all as specified and directed.
52Supplying and fixing,testing the water heater storage type 25 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as specified and directed.
53Supplying and fixing,testing the water heater storage type 6 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as specified and directed.
54Supplying and fixing,testing the water heater storage type 50 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, ccomplete all as specified and directed.
55S & F in repairs Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick over and including 10mm thick cement plaster in CM 1:4 set or as per existing and jointed in neat cement slurry and pointed in white or colour cement to match existing surfaces complete all as specified and directed.
56M& L for Complete removal of existing treatment Washing, rubbing down and stopping of distempered and painted surfaces of wall and then applying two coats of oil bound distemper over and including 2mm thick wall care putty over a coat of chalk whitening primer including preparation complete all as specified and directed.
57S&F stop valves, CP, screwed down, high pressure, with crutch or butterfly handle , screwed both ends for iron pipe or for unions and fixed of size 15mm complete all as specified and directed.
58Supply and fixing CP mixer for mixing hot & cold water screwed down for iron pipe of size 15mm bore complete all as specified and directed.
59S&F in repairs GI pipe medium grade with all fitting and fixed complete for ceiling fan as down rod of 15 mm bore complete all as specified and directed.
60S&F in replacement GI pipe 40mm medium grade with all fitting and fixed complete for hanging of ceiling fan . complete all as specified and directed.
61M&L for making opening by cutting/chasing existing PCC/Masonary wall for fixing of exhaust fan of 300mm/450 mm sweep capacity including grouting of foundation bolts complete plastering and making good distrubed surface good complete all as specified and directed.
62Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge. Note: Painting work measured and paid seperately under respective items. complete all as specified and directed.
63Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed.
64M&L for Sub main wiring single core PVC Insulated cable two run of size 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed.Note : - Two run of 1.5 Sqmm,one run of 1.5 Sqmm cable & one run of PVC conduit shall be measured as one unit run.
65M&L for Sub main wiring single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed.Note : - Two run of 4 Sqmm , one run of 4.0 Sqmm & one run of PVC conduit shall be measured as one unit run.
66M&L for Sub main wiring single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm , one run of 6 Sqmm cable & one run of PVC conduit shall be measured as one unit run.
67M&L for Sub main wiring single core PVC Insulated cable three run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and two run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Three run of 10 Sqmm , two run of 10 Sqmm cable & one run of PVC conduit shall be measured as one unit run.
68M&L for Sub main wiring single core PVC Insulated cable three run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and two run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Three run of 6 Sqmm ,two run of 6 Sqmm cable & one run of PVC conduit shall be measured as one unit run.
69Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside including Modular sheet cover with frame plate of required module size for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces. One light Point/fan point controlled by one switch. complete all as specified and directed.
70~Ditto~ all per srl item No. 69 but for one Bell Point controlled by one switch.
71~Ditto~ all per srl item No. 69 but for one socket point 5 Amp controlled by one switch on same board.
72~Ditto~ all per srl item No. 69 but for one socket point 5 Amp controlled by one switch on Independent board.
73~Ditto~ all per srl item No. 69 but for one light point controlled by two way switch.
74~Ditto~ all per srl item No. 69 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and directed.
75M&L for drawing the wire in with casing caping complete with point wiring with FRLSH PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface for one light/ Fan / Bell Point controlled by one switch. complete all as specified and directed.(Note: Rates are inclusive of PVC boxes of suitable size for mounting switches /Sockets /Regulators etc whereever required)
76~Ditto~ all per srl item No. 75 but for one socket point 5 Amp controlled by one switch on same board.
77~Ditto~ all per srl item No. 75 but for one socket point 5 Amp controlled by one switch on Independent board.
78~Ditto~ all per srl item No. 75 but for one light point controlled by two way switch.
79~Ditto~ all per srl item No. 75 here in above but drawing in with casing caping point wiring using 2.5 Sqmm (Nominal area)triple layer FRLSH PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete all as specified and directed..
80S&F call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified and directed.
81S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and directed.
82S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and directed.
83S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified and directed.
84S&F Switch socket combination 5 in 1, 5 pin 5/6 Amps flush type universal of polycabonate body complete all as specified and directed.
85S&F Switch socket combination 5 in 1, 5 pin 6/16 Amps flush type universal of polycabonate body complete all as specified and directed.
86S&F lamp holder / batten or angle holder Insulated body incl 9 w LED bulb with back plate suitable for batten fittings complete all as specified and directed
87S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified and directed.
88S&F Ceiling Fan regulator electronic type suitable for upto 80 Watt capacity of polycarbonate body ISI marked complete all as specified and directed.
89S&F in replacement of modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and directed
90S&F in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and directed
91S&F in replacement of modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed.
92S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed .
93S&F in replacement of frame with cover plate for modular switch 2 module including screws and washers etc model/make as per existing in site complete all as specified and directed.
94S&F in replacement of frame with cover plate for modular switch 3 module including screws and washers etc model/make as per existing in site complete all as specified and directed.
95S&F in replacement of frame with cover plate for modular switch 6 module including screws and washers etc model/make as per existing in site complete all as specified and directed.
96S&F in replacement of frame with cover plate for modular switch 8 module including screws and washers etc model/make as per existing in site complete all as specified and directed.
97S&F in replacement of frame with cover plate for modular switch 12 module including screws and washers etc model/make as per existing in site complete all as specified and directed.
98S&F in replacement modular fan regulator, 1/2 Module suitable for upto 80 watts heavy duty 230 volts as per existing model/make complete all as specified and directed.
99S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and directed.
100M&L for Periodical checking & maintenance of smart prepaid energy meter/1-phase /3-Phase meters along with parallel home display unit including checking of connection,display,calibration and rectification of technical faults including repair of minor spares costing upto Rs 400 of Digital meters complete all as specified and directed.
101Supply & fixing in replacement of cubical board of meter box PVC type of min size 750 mm x 500 mm x 150 mm Polycabonate sheet cover of required shape with suitable hinging device with & including meter box in square shape with providing transparent acrylic sheet for looking the meter from outside fixed on wall with required nut, bolts grouting on wall and making holes for connections complete all as specified and directed.
102Supply & fix aluminium strips 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
103Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 8 way , 10 KA breaking capacity rated bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
104Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 4 way , 10 KA breaking capacity rated bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
105Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 12 way , 10 KA breaking capacity rated bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
106S&F in replacement sheet metal enclosure MCB DB double door Triple pole and neutral, 440 volts, 4 way , 10 KA breaking capacity rated copper bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
107S&F in replacement MCB Triple Pole and Neutral 63 Amps,415 V ,10KA breaking capacity complete all as specified and directed.
108S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified and directed.
109S&F in replacement MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified and directed.
110Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified and directed.
111S&F in replacement switch piano type switch two way AC 230 volts 6 Amps as per on existing switch board. complete all as specified and directed.
112Supply & Fixing in repairs RCBO four Pole 240Volt, 63 Amp,100 MA protection for earth over load and short circuit complete all as specified and directed.
113Supply & Fixing in repairs RCBO double Pole 240Volt, 32 Amp,100 MA protection for earth over load and short circuit complete all as specified and directed.
114S&F in replacement MCCB four Pole 415 Volt, 100 amp,16KA breaking capacity complete all as specified and directed.(For VTPN DB)
115Supply & Fixing in replacement , LED luminaire using LEDs 20 watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements with the following specification:- complete all as specified and directed.(1) LED Driver should be complete with att standard portections as design of manufacturer.(2) Voltage operating range: 140-270V(3) THD = max 20%(4) Lumen Efficacy= min 120 Lumen/Watt (5) CCT=4000K/6500 K (CCT will be as per site requirement either 4000 or 6500)
116Supply & Fixing in replacement, LED luminaire using LEDs 10 watt mirror with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements with the following specification:- complete all as specified and directed.(1) LED Driver should be complete with att standard portections as design of manufacturer.(2) Voltage operating range: 140-270V(3) THD = max 20%(4) Lumen Efficacy= min 900 Lumen(5) CCT=6500K
117Supply & fix in replacement of LED Security Light Luminaire 35/40 watt with 4200 or more lumen(120 lm/W) , surge protection device upto 4KV inbuilt and external both, IP65/66 rated , IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paintwith the following specification:- complete all as specified and directed.(1) CRI:- ≥70(2) LED Driver should be complete with att standard portections as design of manufacturer.(3) THD - ≤ 10 %(4) Life (Hrs) :- 50,000(5) CCT:- 5700K
118S&F in replacement decorative wall light fitting made up of Polycarbonate ,Cylindrical shape acrylic type,with LED lamp 9 Watt complete with all fixing arrangements on wall incl connector block, etc complete with all accessories internally pre-wired and connecting up with three core flexible copper conductor cable suitable size complete all complete all as specified and directed.
119S&F in replacement of sheet steel enclosure distribution boards, double door factory made VTPN 4 way 3 phase 415 volts 4 way rated bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits comprising of 3 phase 4 wire of suitable rating complete all as specified and directed.(Note: MCCB & MCB should be paid separately)
120Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron wire 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - complete all as specified and directed. (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
121Schedule of credit of Amount Rs. 77,163.00 to be deducted during AOC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56832208
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.99 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Ceiling Fan, Exhaust Fan, Geyser & Day To Day Maintenance Of Age E/M Under (P) No 1 Jabalpur
Basic Detail
Tender No 8632/KH/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 25 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 49.99 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Not Available
Document List
8632TenderDocuments.pdf
9ac83886-13d3-488d-9fec-c7c7704cf32e.html
BOQ_876902.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
pdf

8632TenderDocuments.pdf

html

9ac83886-13d3-488d-9fec-c7c7704cf32e.html

xls

BOQ_876902.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders