Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56830036

Tender For Repair And Maintenance Of 33 Kv Ahr&R Grid Including 33 Kv Gis And 11 Kv Ais Panel, Repair And Maintenance Of 8/10 Mva Power Transformer, 11 Kv Rmus And Connected Items Under Age (Sldc) Electric Supply Under Ge (U) Elect Supply, Delhi Cant

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
57.61 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
16 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of 33 Kv Ahr&R Grid Including 33 Kv Gis And 11 Kv Ais Panel, Repair And Maintenance Of 8/10 Mva Power Transformer, 11 Kv Rmus And Connected Items Under Age (Sldc) Electric Supply Under Ge (U) Elect Supply, Delhi Cantt-10.

BOQ

Name of Work:- REPAIR AND MAINT OF 33 KV AHR&R GRID INCLUDING 33 KV GIS AND 11 KV AIS PANEL, REPAIR AND MAINT OF 8/10 MVA POWER TRANSFORMER, 11 KV RMUS AND CONNECTED ITEMS UNDER AGE (SLDC) ELECTRIC SUPPLY UNDER GE (U) ELECT SUPPLY, DELHI CANTT-10.
Sl. No. Item Description
1Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 33 KV HT cables of different sizes from both ends, removal of fault, Re-connections and testing of cables after removal of fault complete all as specified and directed.Note-: (a) 33 KV HT & 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs.(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
2Supply and fix Cable jointing kit for 33 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 400 Sqmm 3 Core complete all as specified and directed.
3Supply and fix Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 400 Sqmm 3 Core complete all as specified and directed.
4Material and labour for emergency maintenance work of 33 KV HT underground lines by deploying skilled electricians and labours at faulty site having team of minimum 6 persons and transportation including hydraulic machine and other tools and plant required at site for fault rectification per call complete all as specified and directed.Note:- Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown . In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000/- per fault per hour will be imposed over contractor and will be deduct from his dues.
5Material & labour for repair /overhauling of OLTC ( On load tap changer ) of 33KV/11KV Power transformer of capacities 8/10 MVA at site by carried out following work of CG make :-(a) Opening of top plate of OLTC.(b) Draining out of transformers oil from the OLTC. (c) Stoping of leakage of oil from main shaft of OLTC including renewal of oil seal and all gasket of OLTC.(d) Checking /servicing of moving and fixed contact of OLTC and resistence test of contact.(e) Flushing of OLTC assembly with hot new oil and removing of sludge.(f) Filling of new transformer oil in OLTC .(g) Tightening of all tapping leads and connections. (h) Refixing of top plate of OLTC in original position after overhauling.(i) Electrical testing of manual/auto operation of OLTC.Note :- Transformer oil as required shall be measured and paid separately under respective item No 44 here-in -after as supply only.
6Material and labour for servicing /testing of 33 KV GIS control panel including indoor CT, PT and relays system in control panel of indoor SF 6 Gas Circuit Breaker of capacity 1250 Amps and rating 36 KV by the authorised agency. The complete as details mentioned as under:-(a) Details of servicing of breaker :-(i) Checking of Closing/Tripping coil assembly(ii) Adjustment of mechanism if required.(iii) Clean the circuit breaker to remove dust and dirt. (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts.(v) Check for rust and wear.(vi) Checking of spring charge mechanism(vii) Visual check for rust and deformation.(viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc.(ix) Check for loosened connections, rust, damaged lead wires.(x) Checking of control circuit & tighten the connections if any.(xi) Check close & trip coil.(xii) renewal of Dashpot/shock absorbers .(xiii) renewal of carbon brush of spring charging motor(xiv) Cleaning of porcelain bushing(xv) Checking of limit switch
7(b) The following test shall be carried out:-(i) Primary Injection Test of outdoor CT / PT(ii) Closing & Opening Timing Test for all three poles.(iii) IR Test with megger in open and closed condition.(iv) Contact resistance test for all three poles(v) Closing coil resistance(vi) Tripping coil resistance.(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-(i) Over current and earth fault relay(ii) Line diffrential relay(d) Testing of followig Aux relay:-(i) DC Supply supervision relay.(ii) Trip Circuit suprvision relay(ii) SF 6 gas pressure low.(iii) PT Fuse failure relay(iv) Master trip relay(v) Under voltage relay(vi) Over voltage relay
8Material and labour for servicing /testing of transformer breaker/control panel including outdoor CT, PT and relays in control panel of indoor 33 KV GIS breakder Panel of capacity 1250 Amps and rating 33 KV complete as details mentioned as under:-(a) Details of servicing of breker :-(i) Checking of oil level in each pole(ii) Checking of visible oil leaks(iii) Cleaning of porcelain bushings(iv) Checking of oil leakage from oil dash pot in operating mechanism(v) Checking of contact burning(vi) Cleaning and lubricating(vii) Checking/tightening of all electrical terminals and earth terminals and earth connections.(viii) Checking of auxiliary switch(ix) Checking of limit switches and friction clutch.(x) Checking of closing/tripping coils(xi) Checking of spring chargingmechanism(xii) Adjustment of mechanism if required.(xiii) Check for rust and wear.(xiv) Visual check for rust and deformation.(xv) Check for loosened bolts and nuts, broken spring washers and snap pins etc.(xvi) Check for loosened connections, rust, damaged lead wires.(xvii) Checking of control circuit & tighten the connections if any.(xviii) renewal of Dashpot/shock absorbers .(xix) renewal of carbon brush of spring charging motor
9Material and labour for epoxy coating on CT, PT, insulators in 11 KV VCB panels complete all as specified and directed.
10Material and labour for servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 1250/800/630 Amps and rating 11 KV complete as details mentioned as under:-(a) Details of servicing of breaker :-(i) Adjustment of mechanism if required.(ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth.(iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts.(iv) Check for rust and wear.(v) Check Spring Tension and pitting of the Cluster Contacts.(vi) Visual check for rust and deformation.(vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc.(viii) Check for loosened connections, rust, damaged lead wires.(ix) Check whether the contacts are damaged by arcing.(x) Checking of control circuit & tighten the connections if any.(xi) Check close & trip coil.(xii) Checking of Jaw Contacts Conditions and repair/adjust.(xiii) renew the jaw contacts,If required.(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.(xv) renewal of Dashpot/shock absorbers .(xvi) renewal of carbon brush of spring charging motor
11(b) The following test shall be carried out:-(i) Primary Injection Test of CT / PT(ii) Closing & Opening Timing Test for all three poles.(iii) IR Test with megger in open and closed condition.(iv) Contact resistance test for all three poles(v) Closing coil resistance(vi) Tripping coil resistance.(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-(i) Over current and earth fault relay(d) Testing of followig Aux relay(i) DC Supply supervision relay.(ii) Master trip relay
12Material & labour for repair /servicing of marshalling box panel of 33KV/11KV Power transformer of capacities 8/10 MVA including follwing :-(a) Testing & repair to control wiring.(b) Testing of OTI, WTI gauge/ meter matching with OTI, WTI indicator in RTCC panel.(c) Testing of fuse/ MCB (d) Repalacement of gaskets & locks including preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of etc complete all as specified and directeed.
13Material and labour for Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of Terminal Kiosk (TK) at 33 KV Yard with spraying machine including writing description of equipment in block English letter 25 mm high with white /black synthetic enamel paint ccomplete all as specified and directed.
14Disconnecting power supply, Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of 33 KV 8/10 MVA transformer and its accessories with spraying machine in the yard including writing description of equipment in block English letter 50 mm high with white/Black synthetic enamel paint and re-connection after painting complete all as specified and directed.
15Material & labour for cleaning of the bay/yard manually without damaging any equipments, cable or parts of the 33 KV Grid bays, removing of dusts/grass/hurbs etc complete all as specified and directed.
16M & L for cutting and removing grass, vegetation bushes etc from inside boundary wall and outsite boundary wall of 33/11 KV Sub Stn, around 33 KV towers and removing all rubbish to a distance not exceeding 50 m as directed.
17Supplying ,fixing , testing of master trip relay , 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
18Supplying ,fixing , testing of Trip circuit supervision relay, 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
19Supplying ,fixing , testing of DC supervision relay relay , 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
20Supplying ,fixing , testing of SF 6 gas pressure supervision relay , 50/24 Volt DC in control panel including wiring and taking down old UNSV relay complete all as specified and directed.
21Supplying and fixing in renewal PT fuse for 11 KV/110 V PT complete as directed at site.
22Supply installation, testing and commissioning in renewal Potential Transformer (PT)cast resin indoor single phase ( Earthed type) of voltage ratio 33 KV/110 V class 3P - 0.5-3, burden 50 VA insulation level of 70/170 KV as specified below:-(a) Normal System Voltage-33 KV(b) Highest System Voltage-36 KV(c) Rated Primary voltage- 33 KV/√3(d) Rated secondary voltage- 110 V/√3(e) Nos of Lt winding 2(f) Metering Core Accuracy class - 0.5(g) Metering Core Rated Burden- 50 VA(h) Nos of Phase- Single (Earthed Type)(j) Protection core accuracy class - 3P(k) Protection core rated Burden - 50 VA(l) Rated Voltage Factor - 1.2 continuous & 1.5 for 30 Sec(m) Insulation Level- 36/70 KV.170 KVP(n) Temp rise at rated contineous thermal current over ambient at site - 45 0C(o) Porcelain Bushing type - Hollow Cylinder(p) 1.2/50 mcro second impulse withstand test vol -170 KV (Peak)(q) Creepage distance of HV bushing - 900 mm (min)(r) Primary & Secondary winding material - Copper
23Supply, installation, testing and commissioning in renewal 33 KV current transformer cast resin indoor single phase, oil immersed and self cooled type of ratio 800-400/1-1-1-1 suitable for metering and protection equipment installed on control panels terminal block as specified below :-(a) Normal System Voltage-33 KV(b) Highest System Voltage-36 KV(c) Rated Primary current- 800-400 Amp(d) Rated secondary current- 1 Amp(e) Nos of Core - 4(f) Core01: Accuracy class 5P10, 10VA, ALF ≥10(g) Core02: Accuracy Class 1.0, 10VA, ISF ≤ 5(h) Core 03 Protection core accuracy class -PS,Protection knee point voltage- 300 Volt at lower ratio(j) Core 04-Spare(k) Continuous thermal current rating 120 % of rated primary current (l)Temp rise at rated contineous thermal current over ambient at site - Less than or equal to 45 degree C(m) Insulation Level- 36/70 KV.170 KVP(n) 1.2/50 Micro second impulse withstand test voltage- 170 KV (peak)(o) Short time thermal current rating for one second - 25 KA/1 Second(p) Dynamic Current Rating - 62.5 KA ( peak)(q) Porcelain Bushing type - Hollow Cylinder(r) Creepage distance of HV bushing - 900 mm (min)(s) Primary & Secondary winding material - Copper Please Enable Macros to View BoQ information
24Supply, installation, testing and commissioning in renewal 33 KV current transformer cast resin indoor single phase, oil immersed and self cooled type of ratio 800-400/1-1-1-1 suitable for metering and protection equipment installed on control panels terminal block as specified below :-(a) Normal System Voltage-33 KV(b) Highest System Voltage-36 KV(c) Rated Primary current- 800-400 Amp(d) Rated secondary current- 1 Amp(e) Nos of Core - 4(f) Core01: Accuracy class 5P10, 10VA, ALF ≥10(g) Core02: Accuracy Class 1.0, 10VA, ISF ≤ 5(h) Core 03 Protection core accuracy class -PS,Protection knee point voltage- 300 Volt at lower ratio(j) Core 04-Spare(k) Continuous thermal current rating 120 % of rated primary current (l)Temp rise at rated contineous thermal current over ambient at site - Less than or equal to 45 degree C(m) Insulation Level- 36/70 KV.170 KVP(n) 1.2/50 Micro second impulse withstand test voltage- 170 KV (peak)(o) Short time thermal current rating for one second - 25 KA/1 Second(p) Dynamic Current Rating - 62.5 KA ( peak)(q) Porcelain Bushing type - Hollow Cylinder(r) Creepage distance of HV bushing - 900 mm (min)(s) Primary & Secondary winding material - Copper Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56830036
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 57.61 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of 33 Kv Ahr&R Grid Including 33 Kv Gis And 11 Kv Ais Panel, Repair And Maintenance Of 8/10 Mva Power Transformer, 11 Kv Rmus And Connected Items Under Age (Sldc) Electric Supply Under Ge (U) Elect Supply, Delhi Cantt-10.
Basic Detail
Tender No CWE(U)/D-10/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 04 Aug 2026
Submission Date 31 Aug 2026
Open Date 07 Sep 2026
Finance
Tender Value 57.61 Lakhs
Tender Fee 1000
EMD 1.11 Lakhs
Exemption Available
Document List
BOQ_876816.xls
cf76fe4c-2e7f-4f04-828e-e289949f44a1.html
Tendernotice_1.pdf
TPD10.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_876816.xls

html

cf76fe4c-2e7f-4f04-828e-e289949f44a1.html

pdf

Tendernotice_1.pdf

pdf

TPD10.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders