Tender For 2.Creation Of 4X25 Kva Distribution Substations Along With Ht Lt Network At Zargar Mohalla Goshna, Wanipura Tantna, Barwah Nelsoo Kulhand, Gowari Dulyoug Under The Jurisdiction Of Jpdcl Ed Doda On Full Turnkey Basis. Under Ut Capax
Tender Overview
Project Description
Tender for 2.Creation Of 4X25 Kva Distribution Substations Along With Ht Lt Network At Zargar Mohalla Goshna, Wanipura Tantna, Barwah Nelsoo Kulhand, Gowari Dulyoug Under The Jurisdiction Of Jpdcl Ed Doda On Full Turnkey Basis. Under Ut Capax
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer Electric Division Doda JPDCL Jammu Name of Work: 2. Creation of 4x25 KVA Distribution Substations along with HT LT network at Zargar mohalla Goshna, Wanipura Tantna, Barwah Nelsoo Kulhand, Gowari Dulyoug under the jurisdiction of JPDCL ED Doda ON FULL TURNKEY BASIS. Under UT Capax Contract No: ED-Doda/JPDCL/41 of 2026-27 Dated: 04-08-2026 Tender value=19.50Lacs EMD=39000, Tender Fee=2000 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # |
| 2 | Item Description |
| 3 | Creation of 4x25 KVA Distribution Substations along with HT LT network at Zargar mohalla Goshna, Wanipura Tantna, Barwah Nelsoo Kulhand, Gowari Dulyoug .( All items are SITC) |
| 4 | 11/0.433kV, 3-phase 25 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, as per amendment 4 of IS 1180-2014 (Aluminium wound) |
| 5 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 6 | 11kV Link Set Heavy Duty with Bace Channel 75x40x40x6 mm |
| 7 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 8 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor |
| 9 | 8 Mtr. Long ST Pole (ST-410 SP15) |
| 10 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 11 | GI Channel/Angle/Flat of sizes including clamps |
| 12 | Aluminium Thimble 95 Sq. mm |
| 13 | Aluminium Bus Bar |
| 14 | Aluminium Paint |
| 15 | Busbar Insulator |
| 16 | Nuts and Bolts. |
| 17 | Earthing of substation |
| 18 | HT for Zargar mohalla Goshna ( All items are SITC) |
| 19 | 8 Mtr. Long ST Pole (ST-410 SP15) |
| 20 | GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces |
| 21 | 30 mm² ACSR Conductor weasal |
| 22 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 23 | Nuts and Bolts |
| 24 | Aluminium Paint |
| 25 | HT for Wanipura Tantna ( All items are SITC) |
| 26 | 8 Mtr. Long ST Pole (ST-410 SP15) |
| 27 | GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces |
| 28 | 30 mm² ACSR Conductor weasal |
| 29 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 30 | Nuts and Bolts |
| 31 | Aluminium Paint |
| 32 | HT for Barwah Nelsoo Kulhand ( All items are SITC) |
| 33 | 8 Mtr. Long ST Pole (ST-410 SP15) |
| 34 | GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces |
| 35 | 30 mm² ACSR Conductor weasal |
| 36 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 37 | Nuts and Bolts |
| 38 | Aluminium Paint |
| 39 | HT for Gowari Dulyoug ( All items are SITC) |
| 40 | 8 Mtr. Long ST Pole (ST-410 SP15) |
| 41 | GI Channel X-arm 5 FEET Long 75x45x6mm including clamps and angle braces 60x40x6 mm braces |
| 42 | 30 mm² ACSR Conductor weasal |
| 43 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 44 | Nuts and Bolts |
| 45 | Aluminium Paint |
| 46 | LT for Zargar mohalla Goshna ( All items are SITC) |
| 47 | 8 mtr. Long Pole(ST-410, SP15) |
| 48 | GI Mucky-Clamps for Shackle Insulators |
| 49 | 30 mm² ACSR Conductor |
| 50 | 16kN Polymer Shackle Insulators |
| 51 | Nuts and Bolts. |
| 52 | Aluminium Paint |
| 53 | LT for Wanipura Tantna ( All items are SITC) |
| 54 | 8 mtr. Long Pole(ST-410, SP15) |
| 55 | GI Mucky-Clamps for Shackle Insulators |
| 56 | 30 mm² ACSR Conductor |
| 57 | 16kN Polymer Shackle Insulators |
| 58 | Nuts and Bolts. |
| 59 | Aluminium Paint |
| 60 | LT for Barwah Nelsoo Kulhand ( All items are SITC) |
| 61 | 8 mtr. Long Pole(ST-410, SP15) |
| 62 | GI Mucky-Clamps for Shackle Insulators |
| 63 | 30 mm² ACSR Conductor |
| 64 | 16kN Polymer Shackle Insulators |
| 65 | Nuts and Bolts. |
| 66 | Aluminium Paint |
| 67 | LT for Gowari Dulyoug ( All items are SITC) |
| 68 | 8 mtr. Long Pole(ST-410, SP15) |
| 69 | GI Mucky-Clamps for Shackle Insulators |
| 70 | 30 mm² ACSR Conductor |
| 71 | 16kN Polymer Shackle Insulators |
| 72 | Nuts and Bolts. |
| 73 | Aluminium Paint Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 No Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender