Tender For Comprehensive B/R Maintenance Works At Kotdwara Under Age(I) Lansdowne
Tender Overview
Project Description
Tender For Comprehensive B/R Maintenance Works At Kotdwara Under Age(I) Lansdowne- 1 Removing Existing Water Proofing Treatment What So Ever Exist (Except Concrete Padding) And Removing Debries / Rubbish Material Out Side Mod Land Complete All As Specified And Directed. 2 M&L Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust Etc And Brushing Neat Cement Slurry With 3.0 Kg Of Cement Per Sqm Complete All As Specified And Directed. 3 Demolition Of Cement Concrete In Ground Floors And Pavings N Exc 15 Cm Thickness (Below Or Above Ground Level) Including Removal Of Rubbish Out Side Mod Land Complete All As Specified And Directed. 4 M&L For 25Mm Thick Pcc 1:2:4 Type B-0 (Using 12.5 Mm Graded Stone Aggregate) As In Padding Over Rcc Roof And Finishing Cement Concrete Surface Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 5 M&L For 15 Mm Thick Screed Bed Or Bedding Layer In Cm (1:4) Mixed With Water Proofing Compound (Liquid Type) As Per Manufacturer Instruction On Concrete Roof Surface Finished Fair And Even To Maintain The Proper Slope Of Roof Surface Etc Complete All As Specified And Directed.Note :- Wpc (Liquid Type) Shall Be Measured And Paid Separately As Supply Only. 6 M&L Of Water Proofing Treatment To Non-Accessible Roof Slab With App Based Modified Polymeric Membrane As Per Manufacturer’S Instructions With Following Course Of Description Below :- (A) Applying A Priming Coat Of Industrial Bitumen 85/25 @ Of 1.2 Kg Per Sqm, Till The Surface Is Properly Impregnated.(B) Providing App Based 5 Layer Polymeric Membrane Minimum Weighing 3.0 Kg/ Sqm And Minimum 3 Mm Thick Reinforced With Polyester Non-Woven Fabric (Weight Not Less Than 150 Gms/Sqm) Centre Core, Laid On Primed Surface By Torced Applications As Per The ManufacturerS Instructions With Side Over Lap Of 100 Mm And End Overlap Of 150 Mm. All Overlap Joints Shall Be Sealed Thoroughly By Thermo Fusing Both The Membrane Layer (Torching Overlap By Propane Or Butane Gas Torch ) And Sealing It With The Help Of Hot Trowel. The Overlap Joints Shall Be Made As A Monolithic Layer(C) Apply Two Coat Of Solar Reflective Bituminous Aluminium Paint Over A Coat Of Aluminium Red Oxide Over The Membrane 1. The Work Of Water Proofing Treatment Shall Be Got Executed Through Authorised Applicator Of The Manufacturer Only And 10 Year Company Back Warranty To Be Submitted By Contractor 2. The Work Is Required To Be Carried Out At Non-Accessible Roof Slab . The Contractor Shall Make Arrangement Of Scaffolding, Safety And Security Of Workers And Arrangement For Approach To Roof.The Rates Quoted Shall Deemed To Be Included For These Items.) 7 M&L For 75 Mm Thick Pcc (1:4:8) Type D2, (Using 40 Mm Graded Stone Agg) As In Sub Base Etc Finished Even And Rough To Recive Top Layer Complete All As Specified And Directed. 8 M&L For Chequered Cement Concrete Tiles With Grey Cement And Pigment Of Size 30Cmx30Cmx 30Mm Thick, Set And Jointed And Pointed In Neat Cement Slurry In Floor Etc Over And Including 15Mm Thick Screed Bed In Cm 1:6 Including Dismantling Of Existing Tiles Complete All As Specified And Directed 9 Dismantling Of Plain Or Corrugated Steel Sheeting, Any Gauge, Thickness In Roof Coverings Complete All As Specified And Directed. 10 S&F Pre-Painted Galvalume Aluminum Zinc Coated Gi Based Corrugated Steel Sheet 0.50Mm Thick Of Colour, As Approved By Age(I) Having Tensile Strength Of 550 Mpa, Az-150 As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 11 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Colour As Approved Age(I) Having Tensile Strength Of 550 Mpa, Az-150 As In Roof Covering/ Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 12 Dismantling Of Timber Scantling 40 Sqcm And Over In Section, In Any Position As In Unframed Work Complete All As Specified And As Directed. 13 S&F Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc. Conforming To Fe-290- W(Gde- E-165) Quality- A Complete All As Specified And Directed. 14 Demolition Of Brick Work Or Stone/ Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins,Arches, Pillars,Etc. But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles Complete All As Specified And Directed. 15 M&L For Brick Work With Old Size Full Brick Subclass ‘B’ Burnt Clay Bricks, Straight Or Curved On Plan Exc 6M Mean Radius, Built In Cm (1:6) Complete All As Specified And Directed. 16 Taking Down Cement Plaster On Brick Or Stone Wall Surfaces Including Glazed Tiles Wherever Exists Including Raking Out Joints, Hacking For Key And Scrubbing Down With Water Etc And Removing Unseviceable Materials Out Side Mod Land Complete All As Specified And As Directed. 17 M&L Rendering 15 Mm Thick In Cm 1:4 On Brick Work Or Concrete Surfaces Finished Even & Smooth (Without Using Extra Cement) Completed All As Specified And Directed. 18 M&L Rendering 10 Mm Thick On Brick Work Or Concrete Surfaces In Cm (1:6) Finished Even & Smooth (Without Using Extra Cement) Completed All As Specified And Directed. 19 M & L For Preparation Of New Plasterd Surfaces And Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Over Complete All As Specified And Directed. 20 M & L For Preparation Of New Plasterd Surfaces Of Wall And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Alkali Resistance Primer Over 1 Mm Thick Wall Putty Complete All As Specified And Directed. 21 Supply Only Liquid Water Proofing Compound Complete All As Specified And Directed. 22 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises From Mod Land Complete All As Specified And As Directed. 23 S & F Glazed Ceramic Coloured Tiles Of Size 450Mm X 350 Mm X 7 Mm Thick On Vertical Surface Such As Skirting, Dado, Risers To Steps Etc Set & Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Colour Of Tiles Over And Including 10 Mm Thick Cement Plaster In Cm (1:4) Complete All As Specified And Directed. Tiles Shall Be Confirming To Is-15622-2017, Group B Iii With Average Water Absorption Between 10% To 15% Length, Width And Strightness Of Sides +0.20% (Max Deviation) Thickness + 4.0% (Max Deviation) Straightness Of Sides And Rectangularity +0.15% (Max Deviation) Surface Flatness +0.22% (Max Deviation). Breaking Strength 500 N (Minimum) And Minimum 95% Tiles Shall Be Free From Visible Defects. Note :- Shade Of The Tiles Including Colour, Design And Pattern Shall Be Approved By Age (I) 24 M & L Non Skid Light Colour Ceramic Tiles Of Any Design And Pattern 7 To 8 Mm Thick (Square/Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over And Including 15 Mm Thick Screed Bed Or Bedding Layer In Cm 1:6. Finished Fair And Even For Laying Floor Finishes/Tiles Etc Complete All As Specified And Directed. Tiles Shall Be Conforming To Is-15622-2006, Group B Ii With Average Water Absorption Between 3% To 6% Length, Width And Strightness Of Sides +0.10% (Max Deviation). Thickness + 5.0% (Max Deviation). Centre & Edge Curvature And Warpage +0.50% (Max Deviation). Breaking Strength 1000N (Minimum) And Minimum 95% Tiles Shall Be Free From Visible Defects. Note :- Shade Of The Tiles Including Colour, Design And Pattern Shall Be Approved By Age (I) 25 Dismantling Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Laid Bedded And Pointed In Any Mortar Removing Servicable Tiles To Store And Rubbish Off The Premises Complete All As Specified & Directed 26 M & L For Granite (Of Any Type) Tiles 20Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing , Rounded Exposed Edge Complete Laid Over 20 Mm Thick Screed Bed In Cm 1:6 Complete All As Specified And Directed 27 M & L For Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing , Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Kota Stone Laid Over 20 Mm Thick Screed Bed In Cm 1:6 Complete All As Specified And Directed. Note :- Size Of The Kota Stone Shall Be Approved By Age (I) 28 Taking Down Chowkhats Or Frames Of Any Description With Shutters (Without Taking Off Shutter From The Frames) Exe 1.5 Sqm But Not Exceeding 4.0 Sqm Each Complete All As Specified And Directed 29 S&F Solid Pvc Door Frame Of Size 50Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet, Reinforced With Ms Square Tube, Fixing In Opening As Per Specification &Drawing Complete As All As Specified And Directed. 30 S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail,Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed. 31 S&F 100 Mm Butt Hinges, Cold Rolled Mild Steel Medium Weight Isi Marked Complete All As Specified And Directed 32 S & F 100 Mm Long, Aluminium Anodised, Barrel Tower Bolts, Of Extruded Section Isi Marked Complete All As Specified And Directed 33 S & F Aluminium Handles Cast Type Anodised Of Size 100 Mm Long Isi Marked Complete All As Specified And Directed 34 Dismantling Water Tanks And Removing To Store Of Capacity Exc 500 Ltr But N.Exc 1000 Ltrs Complete All As Specified And Directed. 35 S & F 1000 Litres Capacity Rotational Moulded Polyethylene Water Storage Tanks Triple Layer,White Colour (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including 20 Mm Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe And Fixed Min Weight 20Mm-210Gms Complete All As Specified And Directed 36 Taking Up Or Down Steel Water Tubing (Gi Pipe) And Connections Of Following Bore Complete All As Specified And As Directed :- 37 15Mm Bore 38 20Mm Bore 39 S&F Galvanised Steel Water Tubing (Gi Pipe), Medium Grade With All Fittings (Isi Marked) And Fixed To Wall And Ceiling Of Following Bore Complete All As Specified And As Directed :- 40 15Mm Bore 41 20Mm Bore 42 S&F In Repair 15 Mm Bore Bib Taps, Chromium Plated, Fancy Type, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specified And Directed . 43 S&F In Repair 15 Mm Bore Bib Tap Of Standard Ptmt (Min Wt 90 Gm), Any Colour, High Pressure, Screwed For Iron Pipe And Fixed Complete All As Specified And Directed . 44 S&F In Repairs 15Mm Bore Stop Valves (Angular Stop Valve), Cast Copper Alloy, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Screwed Down High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipe Or For Unions Complete All As Specified And Directed. 45 S&F In Repairs 15 Mm Bore Pillar Taps, Cast Copper Alloy, With Capstan Heads, Chromium Plated , Fancy Type Screwed Down For Pipe,High Pressure , With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts , Screwed For Iron Pipe Complete All As Specified And Directed. 46 S&F In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 550Mm X 400Mm Excluding Taps, Chain And Plug And Porcelain Stopper But Including Cutting For And Pinning In Ends Of And Including Brackets, Waste Pipe & Cp Brass Waste Coupling Of 32Mm Dia Complete All As Specified And Directed.Note : Rate Quoted Under This Item Deemed Included Fixing Of Taps, Plug And Chain And Connecting Up To Supply Pipes, Wastes Or Traps Etc. 47 S&F In Repair Vitreous China Squatting Pan Of “Orissa” Pattern Of Size 580 Mmx 440Mm White With Integral Foot Rest (Excluding Flushing Cistern And Flush Pipe) Including Connection To Trap And To Flushing Pipe, Anti Syphonage Pipe Etc And Making Good To Floor Complete All As Specified And As Directed. 48 S&F In Repair Vitreous China Wash Down Water Closet Pan (Pedestal Pattern), White, With And Including Plastic Seat And Cover, White, Closed Pattern With Flat Bottom And Mild Steel Chromium Plated Or Aluminised Hinging Device, (Excluding Fixing Bolts, Flushing Cistern And Flush Pipe) Including Connection To Drain (Or Outgoing Pipe) And To Flushing Pipe, Anti -Syphonage Pipe, Etc Complete All As Specified And Directed. 49 S&F In Repair Pvc Valveless, Syphonic Action Type Low Level Flushing Cistern White With Inlet Ball Valve, Float And Handle Including Brackets, 10 Ltr Capacity Complete With Flush Pipe(Long Bend) 32Mm Dia Complete All As Specified & Directed. 50 S&F In Repair Cp Waste Coupling 32/40Mm Dia Fittings For Sinks ,Basins Etc With Long Screw Shanks And Fly Nuts Flange End Bedded In Red Lead Cement And Other Fixed Complete All As Specified And Directed. 51 S&F In Repair Pvc Waste Pipe With Adopter 32 Mm Dia Suitable For Whb Or Sink Complete All Specified And Directed 52 S&F In Repair Pvc Connection 15 Mm Size With Ptmt Nut Of Following Length Complete All As Specified And Directed :- 53 450Mm 54 600Mm 55 S&F Grating Doom 100Mm Dia Of Ptmt (With Waste Hole Or Without Waste Hole)(Min Wt 25 Gms) Complete All As Specified And Directed. 56 S&F In Repairs 25 Mm Dia Stainless Steel Curtain Rod With And Including Fixing Of Stainless Steel Socket And Brackets One Pair In Each Rod Complete All As Specified And As Directed.
BOQ
| Sl. No. | Item Description |
| 1 | Removing existing water proofing treatment what so ever exist (except concrete padding) and removing debries / rubbish material out side MoD land complete all as specified and directed. |
| 2 | M&L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed. |
| 3 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of rubbish out side MOD land complete all as specified and directed. |
| 4 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in padding over RCC roof and finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for 15 mm thick screed bed or bedding layer in CM (1:4) mixed with water proofing compound (liquid type) as per manufacturer instruction on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.Note :- WPC (liquid type) shall be measured and paid separately as supply only. |
| 6 | M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of industrial bitumen 85/25 @ of 1.2 kg per sqm, till the surface is properly impregnated.(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.0 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by torced applications as per the manufacturer's instructions with side over lap of 100 mm and end overlap of 150 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of solar reflective bituminous aluminium paint over a coat of aluminium red oxide over the membrane 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab . The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof.The rates quoted shall deemed to be included for these items.) |
| 7 | M&L for 75 mm thick PCC (1:4:8) type D2, (using 40 mm graded stone agg) as in sub base etc finished even and rough to recive top layer complete all as specified and directed. |
| 8 | M&L for chequered cement concrete tiles with grey cement and pigment of size 30cmX30cmX 30mm thick, set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 including dismantling of existing tiles complete all as specified and directed |
| 9 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness in roof coverings complete all as specified and directed. |
| 10 | S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of colour, as approved by AGE(I) having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 11 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of colour as approved AGE(I) having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 12 | Dismantling of timber scantling 40 sqcm and over in section, in any position as in unframed work complete all as specified and as directed. |
| 13 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290- W(Gde- E-165) quality- A complete all as specified and directed. |
| 14 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 15 | M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 16 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water etc and removing unseviceable materials out side MoD land complete all as specified and as directed. |
| 17 | M&L Rendering 15 mm thick in CM 1:4 on brick work or concrete surfaces finished even & smooth (without using extra cement) completed all as specified and directed. |
| 18 | M&L Rendering 10 mm thick on brick work or concrete surfaces in CM (1:6) finished even & smooth (without using extra cement) completed all as specified and directed. |
| 19 | M & L for preparation of new plasterd surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over complete all as specified and directed. |
| 20 | M & L for preparation of new plasterd surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistance primer over 1 mm thick wall putty complete all as specified and directed. |
| 21 | Supply only liquid water proofing compound complete all as specified and directed. |
| 22 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises from MoD land complete all as specified and as directed. |
| 23 | S & F glazed ceramic coloured tiles of size 450mm x 350 mm x 7 mm thick on vertical surface such as skirting, dado, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10 mm thick cement plaster in CM (1:4) complete all as specified and directed. Tiles shall be confirming to IS-15622-2017, Group B III with average water absorption between 10% to 15% length, width and strightness of sides +0.20% (Max deviation) Thickness + 4.0% (Max deviation) straightness of sides and rectangularity +0.15% (Max deviation) surface flatness +0.22% (max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note :- Shade of the tiles including colour, design and pattern shall be approved by AGE (I) |
| 24 | M & L Non skid light colour ceramic tiles of any design and pattern 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:6. finished fair and even for laying floor finishes/tiles etc complete all as specified and directed. Tiles shall be conforming to IS-15622-2006, Group B II with average water absorption between 3% to 6% length, width and strightness of sides +0.10% (Max deviation). thickness + 5.0% (Max deviation). Centre & edge curvature and warpage +0.50% (Max deviation). breaking strength 1000N (Minimum) and minimum 95% tiles shall be free from visible defects. Note :- Shade of the tiles including colour, design and pattern shall be approved by AGE (I) |
| 25 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar removing servicable tiles to store and rubbish off the premises complete all as specified & directed |
| 26 | M & L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing , rounded exposed edge complete laid over 20 mm thick screed bed in CM 1:6 complete all as specified and directed |
| 27 | M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of kota stone laid over 20 mm thick screed bed in CM 1:6 complete all as specified and directed. Note :- size of the kota stone shall be approved by AGE (I) |
| 28 | Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and directed |
| 29 | S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with MS square tube, fixing in opening as per specification &drawing complete as all as specified and directed. |
| 30 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 31 | S&F 100 mm butt hinges, cold rolled mild steel medium weight ISI marked complete all as specified and directed |
| 32 | S & F 100 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed |
| 33 | S & F aluminium handles cast type anodised of size 100 mm long ISI marked complete all as specified and directed |
| 34 | Dismantling water tanks and removing to store of capacity exc 500 ltr but n.exc 1000 Ltrs complete all as specified and directed. |
| 35 | S & F 1000 litres capacity rotational moulded polyethylene water storage tanks triple layer,white colour (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed min weight 20mm-210gms complete all as specified and directed |
| 36 | Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :- |
| 37 | 15mm bore |
| 38 | 20mm bore |
| 39 | S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall and ceiling of following bore complete all as specified and as directed :- |
| 40 | 15mm bore |
| 41 | 20mm bore |
| 42 | S&F in repair 15 mm bore bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed . |
| 43 | S&F in repair 15 mm bore bib tap of standard PTMT (min wt 90 gm), any colour, high pressure, screwed for iron pipe and fixed complete all as specified and directed . |
| 44 | S&F in repairs 15mm bore Stop valves (angular stop valve), cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 45 | S&F in repairs 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated , Fancy type screwed down for pipe,high pressure , with or without lettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed. |
| 46 | S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm excluding taps, chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc. |
| 47 | S&F in repair vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed. |
| 48 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic seat and cover, white, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti -syphonage pipe, etc complete all as specified and directed. |
| 49 | S&F in repair PVC valveless, syphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia complete all as specified & directed. |
| 50 | S&F in repair CP waste coupling 32/40mm dia fittings for sinks ,basins etc with long screw shanks and fly nuts flange end bedded in red lead cement and other fixed complete all as specified and directed. |
| 51 | S&F in repair PVC waste pipe with adopter 32 mm dia suitable for WHB or Sink complete all specified and directed |
| 52 | S&F in repair PVC connection 15 mm size with PTMT nut of following length complete all as specified and directed :- |
| 53 | 450mm |
| 54 | 600mm |
| 55 | S&F grating doom 100mm dia of PTMT (with waste hole or without waste hole)(Min wt 25 gms) complete all as specified and directed. |
| 56 | S&F in repairs 25 mm dia stainless steel curtain rod with and including fixing of stainless steel socket and brackets one pair in each rod complete all as specified and as directed. |
| 57 | Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones glazed with oil putty fixed with beads or in wooden shutters complete all as specified and as directed. |
| 58 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beads not exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 59 | S&F in repair of Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender