Tender For Special Repair To Building No P-30 (Lpg Shed) At Bhalukmara Under Ge Jorhat.
Tender Overview
Project Description
Tender For Special Repair To Building No P-30 (Lpg Shed) At Bhalukmara Under Ge Jorhat.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 31-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed. |
| 3 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed. |
| 4 | Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 5 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed. |
| 6 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams staircases, landing, chajjas and similar suspended work (reinforcement to be cut as required to facilitate demolition) complete all as specified and as directed. |
| 7 | Demolition of cement concrete of (unreinforced) any description and any position not otherwise specifically provided for and removal of rubbish from the site complete all as specified and as directed. |
| 8 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and segregating serviceable materials and keeping for reuse at site and removing unserviceable materials from site of work complete all as specified and as directed. |
| 10 | Material and labour for hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 11 | Material and labour for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channel, drains and like etc. complete all as specified and as directed. |
| 12 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roof landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 13 | Material and labour for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 14 | Material and labour for 40mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 15 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement laid in panels including joint filled with sealing compound complete all as specified and as directed. |
| 16 | Material and labour required extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 17 | .-Ditto- all as per item No 15.00 above but add or deduct for each 25mm girth or part there of over or under 30cm and -ditto-. |
| 18 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 19 | Material and labour for flat formwork to soffits of suppended slab such as roof slabs, floor slab, landings and similar works, not exceeding 200mm thick (Horizontal or sloping) with rough finished flat surface complete all as specified and as directed. |
| 20 | Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 21 | Supply and fix framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted or forged into spikes ; window framed gurad bars ; barred iron doors, laddrs, framed balasters, walk ways, railings framed work of water and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 22 | Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc complete all as specified and as directed. |
| 23 | Supply and fixing as in replacement steel ventilator with top hung shutters including hinges, steel peg stay, and including cutting holes in wall for fixing the ventilator with hold fast in PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) and makding good the disturbed surfaces in CM (1:4) and with the existing finishes to match complete all as specified and as directed. |
| 24 | Supply and fixing as in replacement 1.25mm thick of laths Steel rolling shutters, without ball bearing including top cover, anchoring rod, hasp and staple and one shop coat of red oxide zinc chrome primer erected in position, complete ; operated type with bevel gear box and crank handle type complete all as specified and as directed. |
| 25 | Supply and fixing safety 4 lever mild steel locks suitable for rolling shutters complete all as specified and as directed. |
| 26 | Supply and fixing ball bearing suitable for rolling shutters complete all as specified and as diercted. |
| 27 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 28 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 29 | Supply and fixing 4mm thick HSPC(High Pressure Steam Cured) board as in false ceiling with powder coated GI/aluminium snap grid/section of size 600mm x 600mm fixed to wall hanging from soffits/trusses using adjustable supporting hanger comprising of 4mm dia MS rod or wire ‘J’ type hook, nuts, bolts, holding down clips with GI/aluminium section of size 36.5mm x 25mm x 1.4mm (main tee) and 23.5mm x 26.4mm x 1.4mm (cross tee) and wall angle of size 25mm x 25mm x 1.4mm complete all as specified and as directed. |
| 30 | Supply and fixing 4.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50 Sqm in each pane complete all as specified and as directed. |
| 31 | Supply and fixing as in replacement stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed. |
| 32 | Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed. |
| 33 | Material and labour for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 34 | Materials and labour for 15 mm thick rendering on brick work in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 35 | Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 36 | Supply only integral water proofing compound conforming to IS-2645 complete all as specified and directed. |
| 37 | Material and labour for preparation of concrete surface and applying tack coat over prepared surface @ 0.50 kg/sqm of 80/110 penetration grade Bitumen and providing 20 mm thick mastic asphalt bitumen prepared surface sticky in accordance with IS Specification No. 1195:2002 (as amended) using mastic bitumen of penetration grade Grade 20/30 @ 4.49 kg mixed with stone dust (lime stone powder with calcium value 80%) @ 0.008 cum and stone chippings of 12.5 mm and 10 mm @ 0.0096 cum and sand @ 0.084 cum for per sqm of 20/30 bitumen. The surface shall be finished with approved anti-skid stone grit on top, including all labour, materials, tools, plant, equipment, handling, laying, finishing and all other incidental works, complete in all respects as specified and as directed. |
| 38 | Materials and labour for preparation of old plastered surfaces of walls after complete removal of existing treatment and applying two coats of cement base paint complete all as specified and as directed. |
| 39 | Materials and labour for preparation of old plastered surfaces of wall and Finishing walls with distempering with 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification with two coats of distemper including priming coat over and including 1mm thick wall care putty after complete removal of existing treatment on walls complete all as specified and as directed. |
| 40 | Materials and labour for preparation of newly plastered surfaces of wall and applying two coats of acrylic washable distemper over a coat of primer over and including 2mm thick wall care putty complete all as specified and as directed. |
| 41 | Material and labour for applying two coats of cement base paint over a coat of alkali resistant primer including preparation of newly plastered surfaces of wall complete all as specified and as directed. |
| 42 | Material and labour for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 43 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 44 | Supply and fixing as in replacement 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 45 | Supply and fixing 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 46 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 47 | Material and labour for (concealed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit medium grade with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator and making good the disturbed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.Note: A. Red colored cable shall be used for live connection; black colored cable shall be used for neutral connection and green colored cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following: - (i) Copper standard wire. (ii) PVC conduit with accessories. (iii) Chase cutting. |
| 48 | Material and labour for (concealed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including steel conduit medium grade with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator and making good the disturbed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.Note: A. Red colored cable shall be used for live connection; black colored cable shall be used for neutral connection and green colored cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following: - (i) Copper standard wire. (ii) Steel conduit with accessories. (iii) Chase cutting. |
| 49 | . -Ditto- all as per item No 47.00 here-in-before but for 3 pin 6 amps switch socket combination on the independent board with 1.5 Sqmm cable and -ditto-. |
| 50 | Supply and fixing for switch socket combination multipurpose 2 in 1, 5 pin 6/16 amps 230 volt flush type complete all as specified and as directed. |
| 51 | Supply and fixing Piano switch flush button single pole one way 5/6 Amps, 240 volt complete all as specified and as directed. |
| 52 | Supply and fixing ceiling rose surface Bakelite three terminal complete all as specified and as directed. |
| 53 | Supply and fixing as in replacement MCB DB SPN 8 ways double door including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 54 | Supply and fixing as in replacement MCB SPN, 240 Volts, of 40 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 55 | Supply and fixing as in replacement MCB SP, 240 Volts, of 6-32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 56 | Supply and fixing as in replacement LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 57 | Supply and fixing as in replacement flame proof cum water proof LED batten light fitting of 20 watt certified by CMRI, suitable for gas/vapor group of IIA &IIIB, Zone 1 &2 as per IS-2148(1981) and IS-2206 Part-I having IP 66 degree of protection, cast aluminum alloy material and heat and impact resistance toughen 'A' clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre-wired and including connected up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 58 | Supply and fixing as in replacement Compact street lighting luminaires with deep drawn housing for single 35 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 59 | Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 60 | Supply and laying as in replacement GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables complete all as specified and as directed. |
| 61 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 25 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 62 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 50 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 63 | Supply and laying as in replacement under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 2 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. complete all as specified and as directed. |
| 64 | Supply & fixing as in replacement single pointed air termination copper rod 12 mm dia, 300 mm long including PCC and connecting accessories complete all as specified and as directed. |
| 65 | Supply & fixing as in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm complete drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed. |
| 66 | Supply and fixing as in replacement Polycarbonate weatherproof junction Box IP 69 thermoplastic with size 300mm x 300mm x 150 mm or nearest higher size made of polycarbonate with IP 65 degree of protection (EN60529), dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with heat treated Bakelite for terminals block and PVC Glands for cable entry complete all as specified and as directed. |
| 67 | Materials and labour for Checking of any breaking in the link of Earth Strip/Wire of Galvanised Iron and disconnected and jointing them by Exothermic welding or Brazing, complete all as specified and as directed. |
| 68 | Materials and labour for taking down closed/displaced serviceable Aluminium Strip/Copper Strip/GI Strip of running any size and any description with accessories and refixing the same with necessary fixing arrangements like screws, saddles, nuts and bolts complete all as specified and as directed. Note: (i) Cost of screws, saddles, nuts and bolts etc. deemed included in quoted unit rate.(ii) The strip/insulators shall be kept in the safe custody of the contractor.(iii) Necessary precautions shall be taken to avoid any damage to the strip during dismantling and while it remains in the contractor's custody. |
| 69 | Materials and labour for taking down and refixing Air Termination Rod, including all necessary fixing arrangements such as clamps, nuts and bolts, complete as specified and as directed.Note:(i) The Air Termination Rod shall be kept in the safe custody of the contractor.(ii) Necessary precautions shall be taken to prevent any damage to the Air Termination Rod during dismantling and while it remains in the contractor's custody. |
| 70 | Supply and fixing Galvanised Iron Strip 32 × 6 mm with saddles and fixing screws for roof/earth running and down conductors above ground including taking down unserviceable strip complete all as specified and as directed. |
| 71 | Supply and fixing Aluminium Strip 25 × 3.15 mm with saddles and fixing screws for roof/earth running and down conductors above ground including taking down unserviceable strip complete all as specified and as directed. |
| 72 | Supply and fixing as in replacement porcelain insulator for supporting or passing of Aluminium/GI/Copper strip from roof/wall, including necessary nuts and bolts, complete all as specified and as directed. |
| 73 | Material and labour for cutting, bending and welding of MS flat iron 30 mm × 3 mm for making clamps of required size and shape, including nuts, bolts and painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and as directed. |
| 74 | Material and labour for painting to earth pit cover (old/new) with two coats of synthetic enamel paint after cleaning the earth pit cover properly with a wire brush, including numbering of the earth pit in a GI sheet, complete all as specified and as directed.Note: The colour shall be decided by the Engineer-in-Charge. |
| 75 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10Sqm on plan and not exceeding 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 76 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm on soft/loose soil complete all as specified and as directed. |
| 77 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 78 | Material and labour for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreting complete all as specified and as directed. |
| 79 | Material and labour for sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 cm in depth after laying the Cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. |
| 80 | Material and labour for Brick with subclass 'B' bricks in cable protection, laying with built in each other complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender