Housing Urban and Rular Development Government Departments Closing in 7 days TDR #56828099

Tender For Providing Day To Day Maintenance Of All E&M Services At Group Headquarters Ncc Old Rajdhani College Bldg, Kirti Nagar, New Delhi During 2026-27

Issued by Government Departments · Delhi, Delhi
Tender Value
11.59 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
7 days left
EMD
23182
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Day To Day Maintenance Of All E&M Services At Group Headquarters Ncc Old Rajdhani College Bldg, Kirti Nagar, New Delhi During 2026-27

BOQ

Name of Work:- Providing day to day maintenance of all E&M services at Group Headquarters NCC Old Rajdhani College Bldg, Kirti Nagar, New Delhi during 2026-27
Sl. No. Item Description
1Routine maintenance and attending day to day complaints of electrical installations on all working days of the month excluding Sundays and holidays etc.
2Wireman - 1 No.
3Khallasi - 1 No.
4Supply of following electrical accessories for day maintenance in the existing electrical installation/wiring -rewiring etc as reqd
51.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
64.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
7S.P. 5/6 A, one way modular switch, ISI marked
8S.P. 15/16 A, one way modular switch, ISI marked
93 pin 5/6 A modular socket outlet, ISI marked
106 pin 15/16 A modular socket outlet, ISI marked
1140 Amp DPMCB 10 kA breaking capacity
1263 Amp DPMCB 10 kA breaking capacity
1363 Amp TPN MCB 10 kA breaking capacity
143 pole MCCB, 100A, 16kA
153 pole MCCB, 150A, 16kA
163 pole MCCB, 200A, 25kA
17Call bell/ buzzer, single phase
186 pin 25 amp modular type socket
1940 A, rating, 4 pole RCCB, 30mA
2063 A, rating, 4 pole RCCB, 30mA
21Stepped type Modular Fan regulator (2 module)
226 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity
23Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
241200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
25Supplying, Installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), DCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2640 Watt
27Supplying, Installation, Testing and Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
2836 Watt
29Supplying, Installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
30100 watt
31Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
32Group C
33Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
34Supplying, Installation, testing and commissioning of 400 mm Hi-Speed heavy duty wall fan suitable for operation on 230 Volts + 10%, 50Hz Single Phase A.C. Supply.
35Supply, Installation, Testing and Commissioning of 1 H.P. Self Priming Monoblock suitable for 100 mm borewell capable of delivering 0-120 LPM at head of 98-53 mtr. suitable for operation on 240 ± 5% Volt, 50 HZ A.C. supply etc. as reqd.
36Supplying and Fixing of Three Core Flat Cables with bare bunched copper conductor Insulated and Sheathed with PVC for Submersible Pump Motors with voltage grade up to 1100 volts conforming to IS 694:1990 duly ISI Marked complete etc. as reqd. (Make: Havells)
373 x 4 sq.mm.
38Servicing and complete overhauling of WTAC/Split units removing of dust from condenser coil, cooling coil and chasis wherever required complete cleaning of fin condenser coil with cleaning agent of superior quality, dismantling of blower motor (if required), washing etc after dismantling of condenser motor replacement of defective parts finally applying two coats of black synthetic paint of approved brand before fixing new 5 mm./6 mm. foam sheet with adhesive testing commissioning etc. complete as reqd.
39Supplying, replacing, fixing, testing and commissioning of the following accessories/components in the existing Split/Window Type Air Conditioner Units of capacity 1.0 TR to 2.5 TR, including dismantling and taking over of defective/unserviceable component , removal from site, refrigerant recovery and recharging wherever required, brazing/welding, insulation, electrical connections, alignment, calibration, testing of performance parameters and commissioning of the unit to ensure satisfactory operation, complete in all respects as required. including the buy-back of the dismantled/unserviceable component removed from the AC unit
40Inverter type AC PCB (Complete Set of IDU+ODU)
41Non-inverter type AC PCB (Complete Set of IDU+ODU)
42Inverter type compressor
43Non-inverter type compressor
44Repairing of PCB (Printed Circuit Board) of existing Split/window Type Air Conditioner Unit of any capacity by diagnosing the fault, dismantling the defective PCB, replacement of damaged electronic components such as relays, capacitors, resistors, ICs, transformers, tracks etc. as required, reprogramming/calibration wherever necessary, reinstallation, testing, commissioning and restoring the AC to satisfactory working condition, complete as required.
45Inverter Type AC PCB
46Non inverter Type AC PCB
47Supplying and charging of R-22/R-134 or any other refrigerant gas as per requirement in 1.5/ 2TR capacity WTAC/Split AC unit i/c necessary copper pipe, capllary & fiter i/c brazing the tube leakage, finding, pressure testing and vacummuizzing complete as required.
481.5/2.0 TR WTAC/Split AC
49Supplying, Installation, Testing and Commissioning of 300 mm Sweep fresh air exhaust fan minimum 1400rpm including louvers and shutter, fixing with suitable arrangement, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd.
50Supplying, Installation, Testing and Commissioning of 250mm Sweep fresh air Plastic body with louvers exhaust fan including shutter, fixing with suitable arrangement, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd.
51Dismantling of existing Split Type Air Conditioner Unit of capacity 1.0 TR to 2.5 TR including recovery of refrigerant gas, disconnecting electrical connections, dismantling of indoor and outdoor units, refrigerant copper piping, drain pipe, control cable and associated accessories, making safe the disconnected electrical points, and carefully lowering/removing the units without damage and depositing the dismantled materials in the departmental store or at the location specified by the Engineer-in-Charge, complete as required.
52Installation, testing and commissioning of existing Split Type Air Conditioner Unit of capacity 1.0 TR to 2.5 TR including fixing of indoor and outdoor units at suitable locations, providing and laying interconnecting insulated copper refrigerant piping, condensate drain pipe, control and power cabling between indoor and outdoor units, making necessary wall/floor openings, sealing the openings, charging of refrigerant gas (if required), testing for leakage, electrical connections, earthing of outdoor unit, commissioning and satisfactory operation of the air conditioner complete as required.
53Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
54Buy Back of old dismantle material to agency as received on site
55Switch Socket
56Batten/2x2 Light assorted
57Ceiling fan
58Wall Fan
59MCB(Assorted rating) SP/DP
60PVC Insulated Copper Wire
61Flood Light
62Assorted rating of MCCB
63Exhaust Fan Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56828099
AUTHORITY Government Departments
TENDER VALUE 11.59 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing Day To Day Maintenance Of All E&M Services At Group Headquarters Ncc Old Rajdhani College Bldg, Kirti Nagar, New Delhi During 2026-27
Basic Detail
Tender No 17/EE(E)/WED/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 04 Aug 2026
Submission Date 12 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 11.59 Lakhs
Tender Fee Ref. Documents
EMD 23182
Exemption Not Available
Document List
6cb7f6c9-e775-4737-9505-0c1c26108681.html
BOQ_394536.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

6cb7f6c9-e775-4737-9505-0c1c26108681.html

xls

BOQ_394536.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail