Power Government Departments Closing in 1 days TDR #56827333

Tender For Installation Of Solar Panel On Phc Building At Kodiyeri In Thalassery Municipality - Project No: So 277/26

Issued by Government Departments · Malappuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Aug 2026
1 days left
EMD
12274
Bank guarantee accepted
Document Fee
1159
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Installation Of Solar Panel On Phc Building At Kodiyeri In Thalassery Municipality - Project No: So 277/26

BOQ

Name of Work:- Installation of Solar Panel on PHC building at Kodiyeri in Thalassery Municipality - Project No: SO 277/26
Sl. No. Item Description
1Civil Work
2OD55139/2026-2027Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of200-1000 V DC Input voltage range or nearest range and 400V AC, threephase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power withefficiency not less than 97%, total harmonic distortion less than 3% and suitablefor ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage andfrequency level to suit the Grid Voltage Frequency and adjustable for connecting timeto grid as per KSEB norms, including Data Monitoring System complete withaccessories WIFI/LAN connecting and connected application software etc. fixing onwall using wall brackets and giving all connection as required (Make UTL, Luminous,Microtek etc..
3OD55138/2026-2027Supply and providing Solar Photovoltaic Module Mono Perc Half Cut / Bi facialMono Perc Half Cut of capacity 540 Wp or nearest size, manufactured in India,conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolarPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak wattcapacity, which should not be less than 90% at the end of 10 years and 80% at the endof 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitabledirection at site condition and giving connection and inter connection wire tied usingsuitable steel wire tie as per the system string design and direction of department staff(make UTL, Luminous , Microtek etc..)
4OD55146/2026-2027 Supply and providing wall mounted AC DB for on grid solar system for connectingInverter AC side consists of a). Poly carbonate Enclosure IP65 protection withtransparent front cover with hinged door and termination arrangement, b). SPDUp1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection usingsuitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection andDB fixing on wall using suitable screws and plugs etc as required
5OD55145/2026-2027Supply and providing wall mounted DC DB for on grid solar system for connecting 2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65 protectionwith transparent front cover with hinged/screws door and termination arrangement, b).2set 20A DC Fuse and Holder for +ve and connector for -ve incomer side, c). 2setSPD 1000V DC Up1.9kV,Ucpv 585 VDC, In 15kA, Imax 40kA and giving internalconnection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side,giving all connection and DB fixing on wall using suitable screws and plugs etc asrequired
6OD55142/2026-2027Supplying and drawing 1 run x 4 sq. mm PVC insulated tinned copper conductor,single core Solar DC cable in the existing surface / recessed steel/ PVC conduit asrequired
7OD55134/2026-2027Supply and crimping the Male Female MC4 Solar Panel cable connector includingcrimping and connecting etc as required.
8OD55150/2026-2027Supply & installation of dust and vermin proof, 3 Phase Meter Board and to fixKSEB meters, fuse units etc as required including fixing it on wall, making good thedamages colour washing etc. as required
9OD55144/2026-2027Providing and fixing following capacity TP and N Isolator unit inside the existingpanel board with ISI marked HRC fuses including drilling holes in cubicle panel,making connections, etc. as required.63 Amp
102.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
11OD55137/2026-2027Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. asrequired.Triple pole
122.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
132.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
14OD55141/2026-2027Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range,electronic type in the existing meter board complete with connections, testing andcommissioning etc. as required (including testing if required, test certificate forsubmitting KSEB)
15OD55135/2026-2027Supply and wiring with PVC insulated stranded single core copper conductor cablesfor interconnecting the control devices/ equipment's including the wiring firm bysuitable tie/ tie mounts/ PVC duct etc as required. 10 Sqmm single run
16OD55148/2026-2027Supplying and fixing Three phase 4 wire KWh Net meter, 415V, 10 - 100 A or nearestrange ,electronic type in the existing meter board complete with connections, testingand commissioning etc. as required for charging On grid plant after dismantling theexisting KWH meter (including testing if required, test certificate for submittingKSEB).
171.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
181.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
1990.9.2.1Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 onsurface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.100 x 50 mm CMS with base and lid
2090.9.2.8Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 onsurface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.End cap
2190.6.4.54Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single corecopper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the followingsizes.10.00 sq.mm 4 Run
2290.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps noted alongwith the cables, spacing of clamps not exceeding 60cms, making good the damages ,colour washing etc. as required.4 core 10 sq mm with factory made clamp
2390.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2490.16.1.6Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required6.00 mm copper conductor (4 SWG)
255.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
26OD55152/2026-2027Supply and fixing 2 x 25mm X 3 mm copper strip test joint for the earthing system
27OD55143/2026-2027Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to theearth plate
28OD55147/2026-2027Supply and providing 25x3mm brass bolt
29OD55151/2026-2027Supply and providing 25 x 6mm brass bolt
30OD55149/2026-2027Supply and providing 12x3 mm brass bolt
31OD55136/2026-2027Supply and providing Copper Bounded lightning arrester single spike " Airtermination rod " are placed on top of the structure using suitable base plate andnut bolt and giving connection to existing lightning down conductor etc as required.
3290.16.3.9Supply and clamping the following size of strips on surface of wall/ parapet/ existingcable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy dutyGI spacer saddles spacing of clamps not exceeding 1 m, making good the damages,colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
33OD55140/2026-2027KSEB and Electrical inspectorate Charge for availing approval from electricalinspectorate if required and on grid solar system feasibility and charging charge(Actual amount will be reimbursed on production of receipts)
34APP A: Installation of Solar Power Plant
354.1.3Providing and laying in position cement concrete of specified grade excluding the costof centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand(zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources)
364.3.1Centering and shuttering including strutting, propping etc. and removal of form workfor:Foundations, footings, bases for columns
3750.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete
3810.25.2Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works
39OD55154/2026-2027Fabrication supply conveyance and installation of Granite name board indicating thecost involved, commencement date, completion date and inaguration date etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56827333
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 11-08-2026
Authority
Authority Name Kerala Electrical And Allied Engineering Co Limited
Work Description Tender for Installation Of Solar Panel On Phc Building At Kodiyeri In Thalassery Municipality - Project No: So 277/26
Basic Detail
Tender No KEL/ KEMG/83 /2026-27
Bidding Type Tender
Location
City Malappuram
State Kerala
Key Dates
Publish Date 04 Aug 2026
Submission Date 11 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 1159
EMD 12274
Exemption Available
Document List
bcb99fd5-c8d3-471f-b7e5-6e5c52b5187d.html
BOQ_1461967.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

bcb99fd5-c8d3-471f-b7e5-6e5c52b5187d.html

xls

BOQ_1461967.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders