Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #56826495

Tender For Maintenance Of Internal Elect Services & Allied Work In The Aor Of Ge (P) No-1 Jabalpur

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
49.99 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
5 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Internal Elect Services & Allied Work In The Aor Of Ge (P) No-1 Jabalpur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Aug-2026 ERRATA/ AMENDMENT TO TENDER DOCUMENTS AND BOQ Other 25-Aug-2026
2 25-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-Sep-2026

BOQ

Name of Work:- MAINTENANCE OF INTERNAL ELECT SERVICES & ALLIED WORK IN THE AOR OF GE (P) NO-1 JABALPUR
Sl. No. Item Description
1Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and directed. Note: Painting work measured and paid seperately under respective items.
2Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed.
3M&L for Sub main wiring single core PVC Insulated cable two run of size 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed. Note : - Two run of 1.5 Sqmm,one run of 1.5 Sqmm cable & one run of PVC conduit shall be measured as one unit run.
4M&L for Sub main wiring single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed. Note : - Two run of 4 Sqmm , one run of 4.0 Sqmm & one run of PVC conduit shall be measured as one unit run.
5M&L for Sub main wiring single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm , one run of 6 Sqmm cable & one run of PVC conduit shall be measured as one unit run.
6M&L for Sub main wiring single core PVC Insulated cable three run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and two run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Three run of 10 Sqmm , two run of 10 Sqmm cable & one run of PVC conduit shall be measured as one unit run.
7Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside including Modular sheet cover with frame plate of required module size for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces for One light Point/fan point controlled by one switch. complete all as specified and directed.
8~Ditto~ all as per item No.7 but for one Bell Point controlled by one switch.
9~Ditto~ all as per item No.7 but for one socket point 5 Amp controlled by one switch on same board.
10~Ditto~ all as per item No.7 but for one socket point 5 Amp controlled by one switch on Independent board.
11~Ditto~ all as per item No.7 but for one light point controlled by two way switch.
12~Ditto~ all as per item No.7 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and directed.
13Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces for One light Point/fan point controlled by one switch. complete all as specified and directed.
14~Ditto~ all as per item No. 13 but for one Bell Point controlled by one switch.
15~Ditto~ all as per item No. 13 but for one socket point 5 Amp controlled by one switch on same board.
16~Ditto~ all as per item No. 13 but for one socket point 5 Amp controlled by one switch on Independent board.
17~Ditto~ all as per item No. 13 but for one light point controlled by two way switch.
18~Ditto~ all as per item No.13 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified and directed. .
19M&L for drawing the wire in with casing caping complete with point wiring with FRLSH PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed for one light/ Fan / Bell Point controlled by one switch. complete all as specified and directed. (Note: Rates are inclusive of PVC boxes of suitable size for mounting switches /Sockets /Regulators etc whereever required)
20~Ditto~ all as per item No. 19 but for one socket point 5 Amp controlled by one switch on same board.
21~Ditto~ all as per item No. 19 but for one socket point 5 Amp controlled by one switch on Independent board.
22~Ditto~ all as per item No. 19 but for one light point controlled by two way switch.
23~Ditto~ all as per item No. 19 here in above but drawing in with casing caping point wiring using 2.5 Sqmm (Nominal area)triple layer FRLSH PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board” with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete all as specified and directed. .
24S&F Call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified and directed.
25S&F switch modular bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and directed.
26S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and directed.
27S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified and directed.
28S&F Switch socket combination 5 in 1, 5 pin 5/6 Amps flush type universal of polycabonate body complete all as specified and directed.
29S&F Switch socket combination 5 in 1, 5 pin 6/16 Amps flush type universal of polycabonate body complete all as specified and directed.
30S&F lamp holder / batten or angle holder Insulated body incl 9 w LED bulb with back plate suitable for batten fittings complete all as specified and directed
31S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified and directed.
32S&F Ceiling Fan regulator electronic type suitable for upto 80 Watt capacity of polycarbonate body ISI marked complete all as specified and directed.
33S&F in replacement of modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and directed
34S&F in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and directed
35S&F in replacement of modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed.
36S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed .
37S&F in replacement modular fan regulator, 1/2 Module suitable for upto 80 watts heavy duty 230 volts as per existing model/make complete all as specified and as directed.
38S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and directed.
39Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 8 way , 10 KA breaking capacity rated bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
40Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 4 way , 10 KA breaking capacity rated bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
41Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 12 way , 10 KA breaking capacity rated bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
42S&F in replacement sheet metal enclosure MCB DB double door Triple pole and neutral, 440 volts, 4 way , 10 KA breaking capacity rated copper bus bar as per IEC Standard with blanking plate wherever required and IP-43 degree protection complete all as specified and directed.
43S&F in replacement MCB Triple Pole and Neutral 63 Amps,415 V ,10KA breaking capacity complete all as specified and directed.
44S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified and directed.
45S&F in replacement MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified and directed.
46Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified and directed.
47S&F in replacement switch piano type switch two way AC 230 volts 6 Amps as per on existing switch board complete all as specified and directed.
48Supply & Fixing in repairs RCBO four Pole 240Volt, 63 Amp,100 MA protection for earth over load and short circuit complete all as specified and directed.
49Supply & Fixing in repairs RCBO double Pole 240Volt, 32 Amp,100 MA protection for earth over load and short circuit complete all as specified and directed.
50S&F in replacement MCCB four Pole 415 Volt, 100 amp,16KA breaking capacity complete all as specified and directed.
51S&F LED surface mounted light fitting square 2'x2', 30/36watt, min 120 lumen/watt , THD max 10 % ,Voltage operating range: 140-270V, including Surge Protection CRI min 80 % warm white along with fixture Surface / Recessed /Pendent mounting LED luminaries with diffuser channel Luminaires , connector block, etc complete with all accessories internally pre-wired and connecting up with three core flexible copper conductor cable suitable size complete all as specified and directed.(Note: CCT will be as per site requirement either 4000 / 5700 / 6500 K)
52S&F 3/5 watt spot COB ceiling light warm white THD max 10 % ,CRI min 80 %, Voltage operating range: 140-270V, incl Surge Protection complete with all accessories internally pre-wired , connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed.
53S&F 12 watt spot COB ceiling light warm white THD max 10 % ,CRI min 80 %, Voltage operating range: 140-270V, incl Surge Protection complete with all accessories internally pre-wired , connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed.
54S&F 18 watt spot COB ceiling light warm white THD max 10 % ,CRI min 80 %, Voltage operating range: 140-270V, incl Surge Protection complete with all accessories internally pre-wired , connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed.
55Supply & Fixing in replacement , LED luminaire using LEDs 20 watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements with the following specification:-(1) IP rating = IP 20(2) CRI= max 80%(3) Surge Protection = 2.5KV(4) LED Driver should be complete with att standard portections as design of manufacturer.(5) Voltage operating range: 140-270V(6) THD = max 20%(7) Lumen Efficacy= min 120 Lumen/Watt (8) CCT=4000K/6500 K (CCT will be as per site requirement either 4000 or 6500) complete all as specified and directed.
56Supply & Fixing in replacement, LED luminaire using LEDs 10 watt mirror with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements with the following specification:-(1) IP rating = IP 20(2) CRI= max 80%(3) Surge Protection = 2.5KV(4) LED Driver should be complete with att standard portections as design of manufacturer.(5) Voltage operating range: 140-270V(6) THD = max 20%(7) Lumen Efficacy= min 900 Lumen(8) CCT=6500K complete all as specified and directed.
57S&F in replacement Double Head polycarbonate wall engage Light with LED 9/10 Watt bulb Green & Red light fitting, complete with fixing arrangements on wall etc complete with all accessories internally pre-wired and connecting up with three core flexible copper conductor cable suitable size complete all as specified and directed.
58S&F in replacement decorative LED mirror light fitting 9/10 Watt with gold metal finish , complete with fixing arrangements on wall etc complete with all accessories internally pre-wired and connecting up with three core flexible copper conductor cable suitable size complete all as specified and directed.
59S&F in replacement decorative LED wall light fitting, clear glass with metal gold finish,with LED lamp 9/10 Watt complete with fixing arrangements on wall wall , etc complete with all accessories internally pre-wired and connecting up with three core flexible copper conductor cable suitable size complete all as specified and directed.
60S&F in replacement Bulk head LED light fitting complete 10 watt LED,IK 09 ,IP 66 with pressure die cast housing making necessary electric connection with copper conductor of suitable size and accessories & length complete all the requirements with the following specification:-(1) CRI:-≥80(2) Surge Protection :- 3.5KV(3) Voltage operating range: 140-270V(4) THD - ≤ 15%(5) Life (Hrs) :- 35,000(6) CCT:- 6500K complete all as specified and directed.
61Supply & fixing in replacement LED light down lighter by recess or surface mounted 12 watt, warm white/cool white, circular/Square, min 110 lumen/W with fixing arrangemnts on ceiling complete all as specified & directed with the following specification:-(a) Shape as per Site requirements either square or Circular.(b) CRI= max 80%(c) Surge Protection = 2.5KV(d) LED Driver should be complete with att standard portections as design of manufacturer.(e) Voltage operating range: 140-270V(f) THD = max 20%(g) Lumen Efficacy= min1800 Lumen(h) CCT=4000/6500K (CCT will be as per site requirement either 4000 or 6500) complete all as specified and directed.
62Supply & fixingin replacement LED light down lighter by recess or surface mounted 15/18 watt, warm white/cool white, circular/Square, min 110 lumen/W with fixing arrangemnts on ceiling complete all as specified & directed with the following specification:-(a) Shape as per Site requirements either square or Circular.(b) CRI= max 80%(c) Surge Protection = 2.5KV(d) LED Driver should be complete with att standard portections as design of manufacturer.(e) Voltage operating range: 140-270V(f) THD = max 20%(g) Lumen Efficacy= min1800 Lumen(h) CCT=4000/6500K (CCT will be as per site requirement either 4000 or 6500) complete all as specified and directed.
63Supply & fix in replacement of LED Security Light Luminaire 35/40 watt with 4200 or more lumen(120 lm/W) , surge protection device upto 4KV inbuilt and external both, IP65/66 rated , IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paintwith the following specification:-(1) CRI:- ≥70(2) LED Driver should be complete with att standard portections as design of manufacturer.(3) THD - ≤ 10 %(4) Life (Hrs) :- 50,000(5) CCT:- 5700K complete all as specified and directed.
64Supply, fixing and connecting LED top post lantern 20/25 watts, CCT 3000 K / 5700K decorative luminaire with diffuser, including Surge protection device ,IP 65/66 Rated protection 240 volts, 50 Hz, with mounting arrangements ,3 core cable connection and fitiings incl taking down of existing fitting complete all as specified and directed.
65S&F in replacement decorative wall light fitting made up of Polycarbonate ,Cylindrical shape acrylic type,with LED lamp 9 Watt complete with all fixing arrangements on wall incl connector block, etc complete with all accessories internally pre-wired and connecting up with three core flexible copper conductor cable suitable size complete all as specified and directed.
66Note For Item No. 51 to 65(a) LED CHIP, DRIVER & HOUSING IN SAME MAKE DRIVER COMPLIANCES IS LUMINAIRE CERTIFIED BIOLOGICAL TEST REPORT BY OEM LAB APPROVED BY NATIONAL TEST HOUSE. (b) NABL testing Certificate must be required at the time of make approval by the GE.(c) Tender shall submit LM-80 Report for LEDs and LM-79 report from NABL. (d) Contractor has to furnish a replacement warranty of two years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases:- (i) Manufacturing defects. (ii) Failure due to machanical and electrical impact. (iii) Drop in lumen (or Lux at 1m below 90% of clamied values of lumens (or lux at 1m of the LED/Luminaries. (iii) All LED light/luminare must meet the provision laid down in IS-16101,16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II section 13. (e) Minor items required for completion of job included in overall cost quoted by contractor. Nothing extra shall be payable on this account.
67Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 16 SQMM 4 CORE including suitable size lugs & suitable size of DWC pipe including taking out /dismantling of existing cable. complete all as specified and directed.
68Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 10 SQMM 4 CORE including suitable size lugs & suitable size of DWC pipe including taking out /dismantling of existing cable. complete all as specified and directed.
69Supply, laying or fixing or passing through pipe commissioning and testing of PVC XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 25 SQMM 3.5 CORE including suitable size lugs & suitable size of DWC pipe including taking out /dismantling of existing cable. complete all as specified and directed.
70M&L for GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
71S&F in replacement of sheet steel enclosure distribution boards, double door factory made VTPN 4 way 3 phase 415 volts 4 way rated bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits comprising of 3 phase 4 wire of suitable rating complete all as specified and directed.(Note: MCCB & MCB should be paid separately)
72Repairing of earthing including PCC pit cover ,GI funnel,PCC work of pit ,necessary fixing arrangements like clamps bolts for earthing conductor to be fixed properly in its place and testing of earthing with earthing tester of proper calibration and painting the earthing resistance results on wall and pit cover complete all as specified and directed.
73Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron wire 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. complete all as specified and directed.
74Schedule of credit of Amount Rs. 1,09,141.00 to be deducted during AOC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56826495
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.99 Lakhs
LAST DATE 01-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance Of Internal Elect Services & Allied Work In The Aor Of Ge (P) No-1 Jabalpur
Basic Detail
Tender No 8626/KH/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 25 Aug 2026
Submission Date 01 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value 49.99 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Not Available
Document List
8626TenderDocuments.pdf
BOQ_876837.xls
d905da6a-1d86-44d7-93e5-b987f5f43d87.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 01, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
pdf

8626TenderDocuments.pdf

xls

BOQ_876837.xls

html

d905da6a-1d86-44d7-93e5-b987f5f43d87.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail