Tender For Repair / Maintenance Of Internal Electrification At Niwaru Mil Stn Under Ge Jaipur
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Aug 2026
2 days left
EMD
48000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Internal Electrification At Niwaru Mil Stn Under Ge Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully aluminum /copper point wiring, casing capping /PVC concealed conduit for (light, fan, socket, bell or power etc) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed. |
| 2 | M&L for point wiring with 1100 volts grade PVC insulated, unsheathed, FRLSH multistranded copper conductor cable (conforming to (IS:694 /1990), single core, 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn through and including PVC casing-capping (double lock pattern) not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessoriesd fixed on wall/ceiling or above false ceiling incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one light/fan/exhaust fan point controlled by one, one way switch 6 Amp and making good the disturbed portion as per existing complete all as specified and directed. |
| 3 | ,---ditto--- all as per item No. 2 above but for one 5 pin 5 Amp socket outlet controlled by one switch on indepdendent board complete all as specified and directed. |
| 4 | ,---ditto--- all as per item No. 2 above but for one 5 pin 5 Amp socket outlet controlled by one switch on same board with other switches omplete all as specified and directed. |
| 5 | ,---ditto--- all as per item No. 2 above but with cable of size 2.5 Sq mm for one 5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge. |
| 6 | M&L for point wiring with 1100 volts grade PVC insulated, unsheathed, FRLSH multistranded copper conductor cable, single core (conforming to (IS:694 /1990), 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn through and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor including cutting chases in walls for conduits and sunken boxes etc incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one light/fan/exhaust fan point controlled by one, one way switch 6 Amp and making good the disturbed portion as per existing complete all as specified and directed. |
| 7 | ,---ditto--- all as per item No. 6 above but for one light point controlled by two, two way switch complete all as specified and directed. |
| 8 | ,---ditto--- all as per item No. 6 above but for one bell point controlled by one bell push complete all as specified and directed. |
| 9 | ,---ditto--- all as per item No. 6 above but for one 5 pin 5 Amp socket outlet controlled by one switch on indepdendent board complete all as specified and directed. |
| 10 | ,---ditto--- all as per item No. 6 above but for one 3 pin 5 Amp socket outlet controlled by one switch on same board with other switches complete all as specified and directed. |
| 11 | ,---ditto--- all as per item No. 6 above but wiring with cable of size 2.5 Sq mm for one 5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge. |
| 12 | S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed |
| 13 | S&F modular switch, 6 Amps, one way, 240 volts, 1 module complete all as specified and directed. |
| 14 | S&F modular switch 16 Amps, one way, 240 volts, 1 module complete all as specified and directed. |
| 15 | S&F modular socket outlet 2/3 pin 5/6 Amp, 230 Volts, 2 Module flush type complete all as specified and directed |
| 16 | S&F modular socket, 6/16 Amps, 2/3pin combined, 2 module AC 240 volts complete all as specified and directed. |
| 17 | S&F modular bell push, 6 Amp, 1 module complete all as specified and directed. |
| 18 | S&F modular switch, 6 Amp, two way, 1 module AC 240 volts complete all as specified and directed. |
| 19 | S&F modular hum free electronic step fan regulator 120-280 volts of 120 watts capacity including connecting up complete all as specified and directed. |
| 20 | S & F blank spacer plate for single module complete all as specified and directed. |
| 21 | S&F in repair switch modular 1 way 6 Amps, 230 volts, 1 module as per existing make and size complete all as specified and directed. |
| 22 | S&F in repair modular switch 1 way 16 Amps, 230 volts, 1 module as per existing make and size complete all as specified and directed. |
| 23 | S&F in repair modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts. as per existing make and size complete all as specified and directed. |
| 24 | S&F in repair modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts as per existing make and size complete all as specified and directed. |
| 25 | S&F in repair modular bell push, 6 Amp, 1 module complete all as specified and directed. |
| 26 | S&F in repair modular switch, 6 Amp, two way, 1 module AC 240 volts complete all as specified and directed. |
| 27 | S&F in repair modular hum free electronic step fan regulator 120-280 volts of 120 watts capacity including connecting up complete all as specified and directed. |
| 28 | S&F in repair metalic sunken box (metal flush box) 12 module along with modular white cover plate and frame for fixing of modular switches complete all as specified and directed. |
| 29 | ,---ditto--- all as per item No. 28 above but sunken box 8 module complete all as specified and directed. |
| 30 | ,---ditto--- all as per item No. 28 above but sunken box 6 module complete all as specified and directed. |
| 31 | ,---ditto--- all as per item No. 28 above but sunken box 4 module complete all as specified and directed. |
| 32 | ,---ditto--- all as per item No. 28 above but sunken box 3 module complete all as specified and directed. |
| 33 | ,---ditto--- all as per item No. 28 above but sunken box 2 module complete all as specified and directed. |
| 34 | ,---ditto--- all as per item No. 28 above but sunken box 1 module complete all as specified and directed. |
| 35 | S&F in replacement modular MCB 32 Amps double pole, 230 V , 2 module complete all as specified and directed and specified by Engineer-in-Charge. |
| 36 | S&F in repair switch piano flush button single pole one way 5/6 Amp complete all as specified and directed. |
| 37 | S&F in repair switch piano, flush type, single pole, two way 5/6 Amp 240 volts complete all as specified and directed. |
| 38 | S&F in repair switch piano flush button single pole one way 15/16 Amp complete all as specified and directed. |
| 39 | S&F in repair socket outlet, 2-in-1, 5/6 pin,5/ 6 Amps flush type complete all as specified and directed. |
| 40 | S&F in repair socket outlet, 2-in-1, 3 pin 6 & 16 Amps combined flush type compete all as specified and directed. |
| 41 | S&F in replacement 20 Amps, 240 V, modular Switch socket combined with polycarbonate box surface mounting type along with screw complete all as specified and directed by Engineer-in-Charge. |
| 42 | S & F in repair 20 amp single pole and neutral enclosure with 2 pole and earth metal enclosed plug top in powder coated CRCA steel sheet enclosre recess mounted with chained matel cover for socket out let with and incl one no single pole MCB 20 Amps complete all as specified and directed. |
| 43 | S&F in repair bell push, flush type 5/6 Amp complete all as specified and directed. |
| 44 | S&F in replacement Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed. |
| 45 | S&F in repair stepped type electronic fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete all as specified and directed. |
| 46 | S&Fx in replacement 3 mm thick plastic laminated sheet top covers of size 200mm x 120mm for fixing existing switches incl taking out and refixing complete all as specified and directed by Engineer-in-Charge |
| 47 | S&F in replacement 3 mm thick plastic laminated sheet top covers of size 120mm x 120mm for fixing existing switches complete all as specified and directed by Engineer-in-Charge |
| 48 | S&F in replacement fresh air fan of sweep 250 mm, made of sturdy Engineering plastic with self closing louvers, 230V, 50 Hz, 1200 RPM, copper winding incl incl three core 0.75sqmm copper cable connection from ceiling rose to exhaust fan complete all as specified and directed. |
| 49 | S&F in replacement of Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type includign taking down complete all as specified and directed. |
| 50 | S&F in replacement surface mounted LED luminiare, 10 watt, 2 Feet with all accessories having aluminum extruded channel with diffuser for glare free light, high lumen output, driver PF >0.90 having over voltage protection upto 400 volts and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified and directed. |
| 51 | S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 105 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. Make - Philips Cat part BN308C LED20S-6500 L120 PSU WH, Crompton Cat part CIS-305-40-57-SL-DP-NWH, Havells Cat no STOUTPLUS600BS20WLED840SPCWH. |
| 52 | S&F in replacement 36 Watt, LED Panel 2X2 Feet environmental friendly, fully diffused, using engineering grade aluminum diffuser, new generation, aesthetically designed, CRCA housing, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.90, thd<15%, CCT 6500K, with separate electronic driver ceiling light 36W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specified & directed. |
| 53 | S&F in replacement Wall Bracket light fitting (Bldg Security light) 35W housing made out of die cast aluminium alloy with tougned glass , IP 65 protection having clamp for mounting on building wall working on 240V AC 50 Hz , 20 Watts consisting of reflective lens, wired with appropriate driver PF>0.90 having over voltage protection up to 400 volts, surge protection level 7 - 10 KV, thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and LED lumen efficiency >120 lumen Per watt, including fixed on wall with 02 Nos MS Clamps made of 40x6 mm FI and bracket made of 40 mm dia light grade GI Pipe bend to shape, not less than 1.2 m long including connecting with 02 single core PVC insulated copper conductor cable 1100 v grade size 1.5 sqmm complete all as specified and directed. Note : Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above. |
| 54 | S&F in replacement wall decorative glob light glass Single Wall Light Premium Indoor Decorative Light with Smokey Glass & Brush Antique Nickel Design Surface Mounted Classic Wall Light of approved make complete all as specified and directed by Engineer-in-Charge. |
| 55 | S&F in repair MCBs Distribution board tripple pole and neutral (VTPN) 4 ways, powder coated, CRCA steel sheet, suitable for MCCB incomer, degree of protection IP-43, IK09 with reversible double door, 415V, recess mounted having insulated 250 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.Note : MCCB, MCBs and MCB DB shall be of the same make. |
| 56 | S&F in repair flush mounting factory made MCBs Distribution board SPN, 8 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 240V, recess mounted having insulated 200 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. Note : MCCB, MCBs and MCB DB shall be of the same make. |
| 57 | S&F in repair flush mounting factory made MCBs Distribution board SPN, 4 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 240V, recess mounted having insulated 200 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. Note : MCCB, MCBs and MCB DB shall be of the same make. |
| 58 | S&F in repair MCBs of 'C' curve TPN 32-40Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. |
| 59 | S&F in repair MCBs of 'C' curve SPN 32Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. |
| 60 | S&F in repair MCBs of 'B' curve single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. |
| 61 | M&L in repair for sub main wiring with two run of 4 Sqmm single core, PVC insulated, unsheathed, FRLSH multistranded copper conductor cable alongwith one run of 4 Sqmm earth wire as earth continuity conductor (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non-metallic PVC conduit not less than 20mm dia, medium duty, ISI marked, ivory colour with fitting / fixing accessories of suitable size as required including making connection as required incl taking down old wiring with casing capping / conduit including taking down old wiring complete all as specified and directed. NOTE - Two run of 4 sq.mm phase and neutral wire, One run of 4 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. |
| 62 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia medium grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 63 | Note:- (a) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender