Tender for 1) repair maintenance Electrical And Mechanical Services At Trade & Taxes Building, I.P.Estate, New Delhi. 2) repair maintenance Electrical And Mechanical Services At Trade & Taxes Building, I.P.Estate, New Delhi 3) maintenance of electrical installation & Fans, Compound Light And repair maintenance Drinking Water Supply Pump Set, Air Conditioner Equipments Including Heating System Installed At Diet, Ansari Road, Daryaganj, New Delhi. (Sh: Servicing Of Substation Equipments & Various electrical installation Work)
BOQ
| Sl. No. | Item Description |
| 1 | Servicing of VCB with Drawing out VCB bwith the help of rotating draw out handle panel and servicing / overhauling of existing, VMX type VCB of 11 kv, 630 to 800 amps, checking and cleaning of VCB & Draining out the Sewage Water & Wet Waste with Cloathetc& interrupter contacts with waste cloth, blower, tetrachloride etc. checking and cleaning of auxiliary contact (NO/NC) with CTC & bus bar with CRC2-26 spray i/c checking of 24 volts closing/ trapping mechanism, bus bar insulators, spout insulators etc. meggering of VCB on opening/ closing, high voltage testing for vacuum interrupter, continuity test , CRM Test , Time Interval Test for VCB contacts, testing of battery charger unit for 24 volt DC tripping function checking & testing of current transformer (150/5A) of 0.5 accuracy & potential transformer of 110 volts, electrical & mechanical interlocking, earth continuity testing for HT panel etc. complete i/c greasing, setting for spring, charging gear tripping and closing, roller gearsing etc. and refixing the VCB in its chamber, testing, commissioning complete in all respect etc. as reqd. 800 Amp = 7 Nos. |
| 2 | Servicing/overhauling of existing 800Amp to 2500 Amp capacity air circuit breaker of including testing and re-commissioning as required, cleaning of breaker with CRC &checking of control wiring, arcing contacts,microprocessor/ thermal magnetic release,alignment, arc chutes, CT'S, reset & tripping mechanism and connections i/c carrying out contact resistance test, Insulation test and Protection Release LSIG Testing & calibration & tripping mechanism and connections etc. complete as required.2500/2000 Amp = 7 Nos.1250/1000 Amp = 16 Nos.800 Amp = 26 Nos. |
| 3 | Servicing of 1250-1600 KVA Dry Type Transformer complete with Cleaning & Draining of Sewage Water Waste & Wet Carbon from Cloath etc. &Blowering of Dust & Carbon inside the Transformer with Checking of Transformer with IR Value Test, Magnetic Balnace Test , Vector Group Test and Checking the TrppingMechanisium of Transformer from TR-7570 Temp. Winding Relay complete with Test Report with Testing , Commissioning & Heating etc.1600 kVA =3 No.1250 kVA = 1 No. |
| 4 | Supplying, installation, testing &commissioning of 400mm sweep size wall fan of with fan regulator and fixing with the help of dash fasteners including connections etc as required. |
| 5 | Supplying, installation, testing & commissioning of energy efficient 1200 mm sweep size ceiling fan, including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable including providing and fixing phenolic laminated sheet cover on fan box etc. as required |
| 6 | S.I.T.C of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP -65, suitable for operation on 150 V to 270V,(5500 to 6500K), 50 Hz AC Supply, havingpower factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency >85%, 10 kv surge protection, L-70 Life 50,000burning hours. complete i/c dismentalingofexisting fitting if any, connection, etc complete as reqd. a) 45-50 Watt |
| 7 | Supplying, Installation, Testing & Commissioning of Turboforce Heavy duty metal body Air Circulator Wall Fan of sweep size 600 mm, Aerodynamically designed blades for higher air delivery and minimal noise levels,Double ‘z’ shielded ball bearings for longer life,Indexable to different positions up to 15°,Oscillation up to 90° for total flexibility, Sturdy brazed wire guards with powder coating ensures corrosion resistance, operating at 230v, 50 HZ etc as required. |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.8.01) 3 x 1.5 sq. mm |
| 9 | 8.02) 3 x 4 sq. mm |
| 10 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.9.01) 20 mm |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.10.01) 5/6 amps switch |
| 12 | 10.02) 15/16 amp switch |
| 13 | 10.03) 3 pin 5/6 amp socket outlet |
| 14 | 10.04) 6 pin 15/16 amp socket outlet |
| 15 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.11.01) 3 Module (100mmX75mm) |
| 16 | 11.02) 6 Module (200mmX75mm) |
| 17 | 11.03) 8 Module (125mmX125mm) |
| 18 | 11.04) 12 Module (200mmX150mm) |
| 19 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 20 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 22 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 23 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 24 | Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on Wall/surface etc complete as required.17.01) 3 X 10 Sq.mm |
| 25 | 17.02) 4 X 25 Sq.mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender