Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56824086

Tender For Repair/ Replacement Of External Electric Distribution System, Dg, Street Lights, L Post, Summer Appliances And Connected Work At Aizawl Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Aizawl, Mizoram
Tender Value
46.80 Lakhs
Estimated cost
Bid Submission
26 Aug 2026
19 days left
EMD
93600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Aizawl → Mizoram
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of External Electric Distribution System, Dg, Street Lights, L Post, Summer Appliances And Connected Work At Aizawl Mil Stn

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF EXTERNAL ELECTRIC DISTRIBUTION SYSTEM, DG, STREET LIGHTS, L POST, SUMMER APPLIANCES AND CONNECTED WORK AT AIZAWL MIL STN
Sl. No. Item Description
1E & M Division Items
2Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil.
3Excavating in trenches, n exc 1.5 m wide and exc 1.5 m and n exc 3.0 m in depth; for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil.
4Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
5Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
6M & L hard core of gauge n.exc 63mm deposited spread and leveled in layers n.exc 15cm thick, watered and rammed to true surface broken stone or boulders or aggregate around 4 pole , 2 pole structure and transformer etc.as per directed by Engr-in-charge.
7M & L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directedNote: Only punned thickness of sand shall be considered for measurement purposes
8M & L for Bricks common burnt clay building bricks, sub-class ‘B’ locally available laid flat with width equal to length of brick over LT underground cable in trenches for mechanical protection of size 23 cm x 11.5 cm x 7.5 cm thick complete all as specified and directed.
9S & F 80mm bore galvanised steel tubing, Light grade, fixed on the top of the roof with socket/clamps or by welding etc. for fixing single point air termination rod for lightening conductor support as required at site including removing of the old rusted pipe complete as specified and directed.
10S & F 50mm bore galvanised steel tubing, Light grade, fixed on the top of the roof with socket/clamps or by welding etc. for fixing single point air termination rod for lightening conductor support as required at site including removing of the old rusted pipe complete as specified and directed.
11S & F 40mm bore galvanised steel tubing, Light grade, fixed on the top of the roof with socket/clamps or by welding etc. for fixing single point air termination rod for lightening conductor support as required at site including removing of the old rusted pipe complete as specified and directed.
12Supplying laying, jointing and testing for 40mm bore steel Tubes, 'light grade' galvanised,with all fittings and fixed complete to walls or laid under road for passing cables or used as pole for installation of LED Post top lantern complete including dismantling old one complete all as specified and directed.
13Supplying laying, jointing and testing for 25mm bore steel Tubes, 'light grade' galvanised,with all fittings and fixed complete to walls or laid under road for passing cables or used as pole for installation of LED Post top lantern complete including dismantling old one complete all as specified and directed.
14M & L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate for errection of Stay rod, filling and mass concrete etc complete all as specified and directed by Engr-in-Charge
15M & L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for coping of pole, for errection of pole, filling of road cuttings etc complete all as specified and directed by Engr-in-Charge
16M & L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
17S & F hot dipped GI Octagonal pole of 5 mtrs long with single arm of 0.50/1 mtrs, complete arrangement suitable for mounting of LED Street light fitting, with bottom dia 130mm, top dia 70mm with 3mm sheet thickness and foundation nut bolts,Making one hole in pole for cable 4 sqmm 3 core complete including necessory earth work excavation, PCC, RCC in (1:1.5:3) as per OEM Drawings attached complete. (Rate quoted includes all connected works such as excavation, PCC, RCC, reinforcement,nut bolts,etc)
18M & L for steel tubular swaged poles complete with cast iron base plate, final tapper plug, bolt, nuts and screws as specified type 410 SP-55, 11 metre long and applying one coat of aluminium paint over a coat of red oxide zinc chrome primer including dismantling old one complete all as specified and directed.
19M & L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to steel tubular poles, 9/11m high, with two coats of synthetic enamel paint upto a height of 1.5m from ground, in alternate stripes in black & yellow, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2\\"x3\\") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of balance portion of pole, cross arms, brackets with two coats of aluminum paint with all necessary staging, safety precautions, etc. as required complete all as specified all as directed
20Supplying, laying / fixing, commissioning and testing of HT electric cable, aluminium conductor XLPE insulated, earthed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 95sqmm 3 core, 11000 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
21Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 6sqmm 2 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
22Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 10sqmm 2 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
23Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 10sqmm 4 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
24Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 16sqmm 2 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
25Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 16sqmm 4 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
26Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 25sqmm 4 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
27Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 50sqmm 3-1/2 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
28Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 70sqmm 3-1/2 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
29Supplying, laying / fixing, commissioning and testing of LT electric cable, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 95sqmm 3-1/2 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
30Supplying, laying / fixing, commissioning and testing of LT electric cable heavy duty, aluminium conductor XLPE insulated, erathed grade, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath cross sectional area 120sqmm 3-1/2 core, 1100 volts grade, laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed.Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein
31Supplying, laying / fixing, testing and commissioning of electric cable, grade aluminium conductor PVC insulated, erathed grade, Un-armoured cables conforming to IS-7098 (Part-I)-1988, stranded, PVC insulation, PVC tape inner sheath, cross sectional area 6 sqmm 2 core, 1100V grade, laid in trenches/wall/ ceiling/ passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed
32Supplying, laying / fixing, testing and commissioning of electric cable, grade aluminium conductor PVC insulated, erathed grade, Un-armoured cables conforming to IS-7098 (Part-I)-1988, stranded, PVC insulation, PVC tape inner sheath, cross sectional area 10 sqmm 2 core, 1100V grade, laid in trenches/wall/ ceiling/ passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed
33M & L for cable jointing kit for 11kV earthed grade cable heat shrink type joint, outdoor termination with jointing material and accessories suitable for 50 to 95sqmm 3.0 core, XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
34S & F MCB TPN 40 to 100Amps 415V 10KA 'C' curve current carrying capacity in the DB complete with connection testing and commissioning including taking down old one complete all as spcified and directed.
35S & F in repair MCB SPN 6 to 32 Amps, 220 volts, 10 KA, 'C' Series including dismantling old one complete all as spcified and directed.
36S & F in repairs onload change over switch capacity 63 Amp 4 Pole , 415V, 50Hz with SS enclosure of fixed to panel board with necessary arrangement including nuts, bolt, lugs, glands, etc. complete all as specified and as directed
37S & F in repairs onload change over switch capacity 100 Amp 4 Pole, 415V, 50Hz with SS enclosure fixed to panel board with necessary arrangement including nuts, bolt, lugs, glands, etc. complete all as specified and as directed
38S & F in repairs MCCB 4 pole 35kA, 250A, 415V, 50Hz, with thermal magnetic release setting, fixed to panel board with necessary arrangement including nuts, bolt, lugs, etc. complete all as specified and as directed
39S & F in repairs MCCB 4 pole 35kA, 200A, 415V, 50Hz, with thermal magnetic release setting, fixed to panel board with necessary arrangement including nuts, bolt, lugs, etc. complete all as specified and as directed
40S & F in repairs MCCB 4 pole 35kA, 160A, 415V, 50Hz, with thermal magnetic release setting, fixed to panel board with necessary arrangement including nuts, bolt, lugs, etc. complete all as specified and as directed
41S & F in repairs MCCB 4 pole 25kA, 125A, 415V, 50Hz, with thermal magnetic release setting, fixed to panel board with necessary arrangement including nuts, bolt, lugs, etc. complete all as specified and as directed
42S & F in repairs MCCB 4 pole 25kA, 100A, 415V, 50Hz, with thermal magnetic release setting, fixed to panel board with necessary arrangement including nuts, bolt, lugs, etc. complete all as specified and as directed
43S & F in repairs MCCB 4 pole 16kA, 63A, 415V, 50Hz, with thermal magnetic release setting, fixed to panel board with necessary arrangement including nuts, bolt, lugs, etc. complete all as specified and as directed Please Enable Macros to View BoQ information
44S & F in repairs MCCB 4 pole 16kA, 63A, 415V, 50Hz, with thermal magnetic release setting, fixed to panel board with necessary arrangement including nuts, bolt, lugs, etc. complete all as specified and as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56824086
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.80 Lakhs
LAST DATE 26-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of External Electric Distribution System, Dg, Street Lights, L Post, Summer Appliances And Connected Work At Aizawl Mil Stn
Basic Detail
Tender No 8172A/E8
Bidding Type Tender
Location
City Aizawl
State Mizoram
Key Dates
Publish Date 04 Aug 2026
Submission Date 26 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 46.80 Lakhs
Tender Fee 500
EMD 93600
Exemption Available
Document List
72f90078-c83b-4b62-90b7-ceda26cfdd71.html
8172A-SchofCreditformat.pdf
8172A-TP.pdf
BOQ_876799.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

72f90078-c83b-4b62-90b7-ceda26cfdd71.html

pdf

8172A-SchofCreditformat.pdf

pdf

8172A-TP.pdf

xls

BOQ_876799.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders