Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56820750

Tender For Repair And Renovation Of Electrical Work For Development Of Existing Sativata Airstrip For The Year 2026-27

Issued by Government Departments · Bargarh, Odisha
Tender Value
24.68 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
6 days left
EMD
24681
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bargarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Renovation Of Electrical Work For Development Of Existing Sativata Airstrip For The Year 2026-27

BOQ

Name of Work:- Repair and renovation of Electrical work for Development of existing Sativata Airstrip for the year 2026-27
Sl. No. Item Description
1INTERNALRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A
2GROUP-B
3GROUP-C
4Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
5Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
6Supplying,fixing of Computer Board (3nos 10 Amp Modular Switch and Socket) with complete fitting (modular type) (Make-Legrand(myrius),Schneider (Zencelo), Panasonic (vision),Hagar (equievalant) or equievalant) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.
7Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
82 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
92 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
102 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
114 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
121nos single core 1.5 sq. mm copper wire for phase copper wire for phase continuty conductor in 20 mm dia non metallic heavy duty PVC conduit (LDB to LSB/5A SOCKET) 1 x 1.5 sq. mm (for inverter wiring)
132+4 way MCB Enclosure DB (GLAZED door) (for separate AC supply control) Warranty on DB is 3 years
14Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
15Supplying and fixing 32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
16Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
17SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
18Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan with aluminium blades having wattage not more than 60w and air delivery 215m3/min Make- Usha striker and eq. model of Crompton /Havells) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(Regulator compatible)
19Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 2160 lumens, 120 lm/watt, CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
20S/F. of 60Wt. LED Street with G.I. bracket. on wall portico & poles having die cast aluminium housing with toughened glass having lumen output of 7200 or more (As per LM 79 report of third party NABL lab) ,IP 66 protection or more , LED street light model will be vide Panasonic/ Philips/LT/WIPRO or equievalant reputed make & model A catogory, ISI marked as approved, with proper model make having warrantied for a period of 3 years . Of Make: Panasonic/LT /Philips/Wipro /Crompton/Bajaj
21Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature).The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 5 Star Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating (Hitachi-RAS.V518PCDIBT1/ Toshiba-RAS-18G3KCV5SG/ Voltas-VOLTAS SAC 185INV VECTRA ELEGANT)(Category III Make :- Hitachi/ Toshiba/ Voltas)
22Supply and fixing of 4kVA Voltage stabilizer Voltage range starting from 90V (Make-V-Guard/Microtek)
23Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
24DG SETSupply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 25KVA ( Make -Kirloskar / Jakson) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 25KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 25KVA DG Set complete with Battery Charger & leads as required. BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. , control cable of 15mtr 2.5sqmm 6core , civil foundation work. The cost is inclusive of 2 nos. 600mmx600mmx6mm GI plate earthing for body and 2 nos. 600mmx600mmx6mm GI plate earthing for neutral .(The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)
25Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. (a) 3.5core x 50 sq mm (From main panel connection)
26Laying of PVC Insulated PVC Seated /XLPE power cable direct in ground 750mm depth in the trench in one horizental formation including excavation, sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.(a) Cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM.
27Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.(a) 3.5 core x 50 sq mm
28S.I.T.C of 63A Changeover control panel board wallmounted size 32\\"x32\\"x8\\" made out of 16SWG cr sheet painted with one coat of gray enameled paint & two coat of red oxide paint with following arrangement. Incoming- 63A Changeover Switch -1no. Outgoing- 100A Cu busbar- 4set, 63A 2P- 3nos, 40kA SP VSD WITH SP MCB- 4nos. DIgital Instrument- (0-100A/5) MFM,RS 485 with 30A/5 CTS- 3nos, LED Indicating lamp (RYB)- 1set as per IE rules. Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9
29SOLAR AIO STREET LIGHTSupply of Elegant look 60 W (+/-10%) AIO LED Solar Street lights having extruded aluminum housing, 180Wp or more Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more LiFePO4 battery (BIS certified), BMS, MPPT charge controller, PIR sensor to provide 2 days (24 hrs.) back up. The luminaire is having IP 65 protection for critical components, IK 07 and having lumen output of 10000 lumen and having minimum lumen efficacy >160 Im/w) as per LM 79 report third party NABL lab to justify the lumen output & lumen efficacy. Lenses should be provided on the LED chip for better lighting distribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party NABL lab reports to justify the lumen efficacy, luminaire output, IK 07 and IP 65 protection. The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole. The Solar Street light and solar panel having capacity of 180 Wp or more must be designed to take the wind load at 180 KM/HR wind speed (As per wind load test report). The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales service will be provided through their toll-free base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredited laboratory. The following test reports must be submitted for the technical acceptance of the products.1.LM 79 REPORT (Third party NABL lab only), 2. IK 07 (Report of Third party NABL lab only for any wattage of AIO solar light), 3. IP 65 (Report of Third party NABL lab only, 4. Wind load test report of AIO Street light having 180 Wp or more capacity Solar Mono Panel suitable for 180 KM/Hr wind Speed. The AIO solar street light must complies to the following:1.EN50530-MPPT Efficiency, 2. IEC61547, 3. IEC61000-3-2-EMC, 4. IEC 60598-2-3,5. IEC 62109-1, (The necessary test reports of third party NABL lab against the above must be submitted for any wattage of AIO Solar street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of solar lighting company)Make- (Philips/Panasonic/Wipro/Crompton or equivalent). NB: The cost includes 5 years CMC including repair/Maintenance/replacement of the product in case of any defect.
30Supply of 8 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate and 4 nos. Type En 8 grade foundation bolts to withstand 180 KM/HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the pole at two different heights (One light on Pole Top and second light on the differential bracket) (Make Bajaj/RR Ispat Valmont/Utkarsh or equivalent)
31Construction of RCC foundation by using M20gradeRCC and Fe415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation for installation of pole with solar lighten that foundation. The work shall be executed as per the instruction of EIC.
32Installation of 8 mtr pole on the adaptor plate/ foundation after fixing the 60 W AIO Light in the pole by using suitable machinery by taking all safety precautions as per the direction of EIC. (make- as approved by PWD Odisha)
33SOLAR BACK-UPSupply, Installation,Testing and Commissioning of Off-Grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono PERC Half Cut bifacial Crystalline silicon solar cells, netmetering facility, necessary protections, earthing, mounted on hot dip G.I structure (bottom height of panels from roof level shall not be less than 300mm) of suitable strength with following components complete as required:a) Solar Photovoltaic Module of capacity 545 Wp or above, manufactured in India, conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity,which should not be less than 90% at the end of 10years and 80% at the end of 25 years. Mono PERC Half Cut bifacial Crystalline silicon solar Panel- 10 nosb) S.I.T.C of 5.5KVA, 48V MPPT based solar Inverter -1set with 12V, 150Ah solar battery- 4nosc) Data Monitoring System complete with accessories in build with Solar Inverterd) Fixing of Array junction box & Main junction box with IP-65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kVgrade armoured power and control cables between solar modules, main power cable to solar inverter unit alongwith supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Make- (TATA/Waaree/Luminous/Panasonic). NB: The cost includes 5 years CMC including repair/Maintenance/replacement any of the product in case of defect.
34Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.
35Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
36MAINTENANCE OF SUB-STATION & LINES:Cleaning of Sub-station, repairing of cable jointing with new cable lugs & sockets, replacement of net LTD box with MCCB of 100A/125A -25kA, LT cable sockting, replacement of burnt cables, replacement of HT insulators, replacement of silica gel, repair of AB switch for proper lock & break, earthing of neutral & body, colouring of boundary wall & gates, filling of soil around the sub-station for proper level maintenance to drain out watter logging near the transformer area, deposit against any electric bills liability pertaining to the airstrip building and reconnection charges etc. as per direction of site engineer in-incharge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56820750
AUTHORITY Government Departments
TENDER VALUE 24.68 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Repair And Renovation Of Electrical Work For Development Of Existing Sativata Airstrip For The Year 2026-27
Basic Detail
Tender No IFB-SE PWD BGH No.05 OF 2026-27
Bidding Type Tender
Location
City Bargarh
State Odisha
Key Dates
Publish Date 04 Aug 2026
Submission Date 17 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 24.68 Lakhs
Tender Fee 6000
EMD 24681
Exemption Available
Document List
1d5f72cc-e3d4-46b1-94c9-594d072d0d23.html
BOQ_604387.xls
Tendernotice_1.pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

1d5f72cc-e3d4-46b1-94c9-594d072d0d23.html

xls

BOQ_604387.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders