Tender For Special Repair To Bldg No. P-6,P-7 (Single Nursing Ofrs Qtr) At Ahrr Complex Under Ge (E/M) repair renovation Hospital, Delhi Cantt-10.
Tender Value
1.44 Crore
Estimated cost
Bid Submission
31 Aug 2026
16 days left
EMD
2.19 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Bldg No. P-6,P-7 (Single Nursing Ofrs Qtr) At Ahrr Complex Under Ge (E/M) repair renovation Hospital, Delhi Cantt-10.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles all as specified. |
| 2 | M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed. |
| 3 | Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed. |
| 4 | M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in ready mix mortar1:6, finished even and fair without using extra cement, complete all as specified & directed. |
| 5 | M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in ready mix mortar 1:4, finished even and fair without using extra cement, complete all as specified & directed. |
| 6 | M&L for rendering 5 mm thick in ready mix mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and fair without using extra cement complete all as specified. |
| 7 | M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of wall and making the surface even & smooth for receiving distemper/ paint of any description, complete all as specified & directed. |
| 8 | M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of ceiling and making the surface even & smooth for receiving distemper / paint of any description, complete all as specified & directed. |
| 9 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed. |
| 10 | M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of weather resistant acrylic primer, complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed. |
| 12 | M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed. |
| 13 | M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of exterior grade weather proof paint, complete all as specified and directed. |
| 14 | M&L for complete removal of existing treatment on old plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed. |
| 15 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing) and rubbish off the premises, complete all as specified & directed. |
| 16 | M&L 15mm thick screed bed or bedding layer in Ready mix cement mortar (1:4) for laying floor finishes, complete all as specified & directed. |
| 17 | M&L 10 mm thick screed bed or bedding layer in Ready mix cement mortar (1:3) to receive wall tiles, complete all as specified & directed. |
| 18 | M&L for non skid colour ceramic tiles 7-8 mm thick (square/rectangular) area of each tiles exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc, set and joint with adhesive of 6 to 8mm thick type-II(floor), complete all as specified and directed. |
| 19 | M&L for coloured glazed ceramic wall tiles as in vertical surfaces of size 600mm x 300mm x 7 to 8 mm thick, set and joint with adhesive of 6 to 8mm thick type-II(wall), complete all as specified and directed. |
| 20 | M&L for jointfree double charged Virified Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and joint with adhesive of 6 to 8mm thick type-II(wall), pointed in white or coloured cement to match) complete all as specified and directed. |
| 21 | Taking down chowkats or frames including shutter (without taking off shutters from the frame) area not exc 1.50 Sqm each, complete all as specified. |
| 22 | Taking down chowkats or frames including shutter (without taking off shutters from the frame) area exc 1.50 Sqm but n.exc 4.00 sqm each, complete all as specified. |
| 23 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 24 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 25 | S&F Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. |
| 26 | Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER conssisting of density 650 Kg/CBM manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strengh and safety purpose (Confirming as per IS 4020). The door should be water prorf, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 Nos. SS butt hinges size 100mmx25mmx2mm and 33mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws. etc. complete all as specified & directed. Note:- MTC and Screw out test will be provided by contractor. |
| 27 | S&F aluminium powder coated sliding window comprising of sliding runner of three way aluminium frame section (weight not less than 0.80 Kg/RM) as per series-A, consisting of three sliding shutters made out of section (weight not less than 0.55 Kg/RM) with 5.5mm thick glass and wiremesh (two No sliding glass shutters and 1 No wire mesh shutter) fixed with rubber and aluminium beading including down push type locking arrangement in shutter, fixed the frame with rawl plug complete all as specified and directed.(Note:- min thickness of powder coating not less than 50 micron.) |
| 28 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified & directed. |
| 29 | S&F 100 mm long butt hinges, medium weight, cold rolled stainless steel and fixed, complete all as specified. |
| 30 | S&F 100 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed. |
| 31 | S&F 100mm size extruded Stainless steel handles, fabricated type complete all as specified and directed. |
| 32 | S&F stainless steel, sliding door bolt 300mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections, complete all as specified & directed. |
| 33 | S&F 150 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed. |
| 34 | S&F 150 mm long stainless steel handle of extruded section fabricated type anodised and fixed, complete all as specified and directed. |
| 35 | S&F in repair mild steel ordinary rat tail rod pattern springs including roller and roller plate complete 300mm length, complete all as specified and directed. |
| 36 | S&F in repairs stainless steel curtain rod 20-22mm dia including brackets, side knobs etc, fixed to walls, complete all as specified and directed. |
| 37 | S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length 140mm, complete all as specified and directed. |
| 38 | Demolition of stone slabs and tiles of any description or thickness in floors etc laid, bedded and pointed in any mortar complete all as specified and as directed. |
| 39 | M&L for 16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed. |
| 40 | Taking up or down 20mm bore steel tubing and connections, complete all as specified & directed. |
| 41 | All as per ser item No. 38 here-in-before but 25mm bore. |
| 42 | Supplying and laying of CPVC pipe 20mm dia SDR 11 and plain CPVC SDR 11 brass fittings on walls/ceilings or laying in floors including all necessary fittings complete all as specified. |
| 43 | All as per ser item No. 40 here-in-before but 25mm bore. |
| 44 | Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc, complete all as specified & directed. |
| 45 | M&L for providing cement concrete 1:2:4 type B-I (20mm graded agg) in roof kerb or mud slops, rounded or chamfered on edges, coping, kneelers, kerb water tough and the like incl weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified & directed. |
| 46 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls, complete all as specified & directed. |
| 47 | M&L for PVC floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement, including embedding with PCC 1:2:4 type B-1, complete all as specified & directed. |
| 48 | S&F 110mm bore PVC (SWR) bends any radius, complete all as specified & directed. |
| 49 | S&F in repair white vitreous china wash hand basin (flat back) of size 550 x 400 mm fixed on and including new brackets complete including 32 mm size brass chromium plated waste coupling, etc, complete all as specified and directed. |
| 50 | S&F in repair European vitretious china wash down water closet pan P or S Trap (excluding flushing cistern but including flush pipe and pvc seat cover white). |
| 51 | S&F in repairs PVC low level flushing cistern, valve less, Syphonic action type, double push bottom, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete all as specified. |
| 52 | S&F in repairs bib taps, cast copper alloy, fancy type, with crutch or butterfly handle, chromium plated, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed. |
| 53 | S&F in repairs stop valves/angle valve, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type), with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed. |
| 54 | S&F PVC connections 15 mm size with PTMT nuts of length 450 mm, all as specified & directed. |
| 55 | S&F 600 mm x 450 mm size beveled edge mirror 5 mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified & directed. |
| 56 | S&F in repair tubular towel rail stainless steel chromium plated 20 mm dia D type 60 cm long between flanges, including brackets and fixed to walls, all as specified and as directed. |
| 57 | S&F in repairs soap dish, brass CP any type, fixed to plugs with chromium plated brass screws, complete all as specified and as directed. |
| 58 | S&F in repairs shower rose, chromium plated brass, fancy type, 125 mm with or without swivel joint, any size, including fixing to steel pipe or union, complete all as directed. |
| 59 | S&F in repairs Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. |
| 60 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as spd and directed |
| 61 | S&F in repairs 32mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as spd and directed. |
| 62 | Supply and fix in repair 1000 litres capacity double layer, rotational molded, polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe including dismantling tank, complete all as specified and directed. |
| 63 | Demolition of cement concrete (unreinforced)/lime concrete/sunken floor of any description and in any position not otherwise specifically provided for by mechanical means (like drill machine, Hilti, pneumatic chisel, etc) complete all as spd & directed. |
| 64 | M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. |
| 65 | Demolition of cement concrete (reinforced) of any description and as in kitchen slabs, shelves, chimney, Chajjas etc not other specifically provided for complete all as specified and directed. |
| 66 | M&L of RCC of nominal mix type B0 1:2:4 (12.5mm graded aggreate) as in chajjas and like all as spd and directed by Engr-in-charge. |
| 67 | S&F in repair brass CP wall , sink, washbasin mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified. |
| 68 | S&F in repairs 20mm bore of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to pipe all as spd and directed. |
| 69 | S&F factory made 18mm thick 100% solid WPC(Wood Polymer Composite) laminated board of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. |
| 70 | M&L for following : (i) Removing plaster & finishes from all exposed/ damaged portion of coloumns, slabs & beams (ii) After cleaning gently removing cover concrete using pneumatic/ electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete sall be done to an extent when reinforcement is visible (iii) Removal of cover concrete with uder cutting of up to a depth of 20mm beyond reinfocement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed (iv) Cleaning exposed concrete substrate by using water jet. (V) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand balsting if rust is approved (vi) Any other work as directed by Engr-in-Charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. |
| 71 | M&L for providing rust proof/ anti corrosive treatment to bars : (i) cleaing of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufacture (iii) Apply two coats of Epoxy phenolic anti corrosive portective coat on bars alround new & old as recommended by the manufacturer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. |
| 72 | M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris and dust(ii) Applying Epoxy bond coat on the sound substrate using approved apray machine & ensuring that no pin holes are visible (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitoius mortar) of 25-50mm thickness.Note : Application of PMM sghall of preferably be in coats of approx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed within 30mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer cmplete all as specified and directed. |
| 73 | S&F 100mm dia cast iron (spun cast) soil, waste and vent pipes in any length, with or without ears, with lead joints, fixed to walls including dismantling old pipes any type complete all as specified and directed. |
| 74 | S&F 75mm dia cast iron (spun cast) soil, waste and vent pipes in any length, with or without ears, with lead joints, fixed to walls including dismantling old pipes any type complete all as specified and directed. |
| 75 | S&F 100 mm dia cast iron bends/Tee with oval access doors for spun pipes (any radious) with polymer jointing materials, complete all as specified and directed. |
| 76 | S&F 75 mm dia cast iron bends/Tee with oval access doors for spun pipes (any radious) with polymer jointing materials, complete all as specified and directed. |
| 77 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls, complete all as specified & directed. |
| 78 | M&L PCC 1:3:6 Type C1 (using 20 mm graded stone aggregate ) in mass concrete for sunken portion of WC, complete all as specified and directed. |
| 79 | M & L for Water proofing treatment of sunken RCC slab : (i) 15mm thick plater in CM (1:3) mixed with WP compound as per manufacturer's instructions shall be provided on sunken portion while the concrete is green.(ii) Apply cement slury @ 0.488 kg/sqm cement mixed with Acrylic based polymer modified cementious composite compound @ 0.253 kg/sqm and the surface will be allowed to air cure for 4 hours. (iii) Apply another layer of cement slurry @ 0.242 kg/sqm of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 kg/sqm and the surface will be allowed to air cure for 4 hrs. (Make of cement composite compound of Dr. Fixit/Fosroc/Sikka)(iv) Curing the sunken portion with water minimum for 7 days by ponding.(v) Paste 200micron thick poythene film of approved make with approved adhesives to the treated sunken surface.(vi) Joints/Traps/WC/Soil pies shall be properly sealed with approved sealing compound of approved make.(vii) Testing of all traps & joints shall be done after sealing and before filling of sunken slabs and ponding test for 96 hours. (viii) Spout pipe shall be provided for drain out the water in sunken portion.Note : Flat surface shall be measured for payment. |
| 80 | M&L for TMT bars 6 to 8mm dia cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. |
| 81 | S&F Factory made single extruded WPC (Wood Polymer Composite) soild door/ window/ Ceosetory windows & other Frames/ Chowkhat of 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after dentsity of 750 kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), mimimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-Charge. |
| 82 | S&F 75 mm long stainless steel handle of extruded section fabricated type anodised and fixed, complete all as specified and as directed. |
| 83 | S&F of SS auto closing hinges openable at 0 degree for kitchen cabinet shutters and bed room cub boards complete all as specified and as directed. |
| 84 | S&F ball catches with 8 mm dia steel ball and brass body and striking plate including letting in anmd fixed complete all as specified and as directed. |
| 85 | S&F Grating doom 100mm dia of SS (Minimum weight 35gms) all as spd and directed by Engg-in-Charge. |
| 86 | M&L for 25mm thick PCC 1:2:4 TYPE B0 using 12.5mm graded stone aggregate in sub baseof floor complete all as spd and directed. |
| 87 | M&L for machine pressed precast concrete interlocking tiles any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade laid including demolition of old tiles complete all as specified and directed. |
| 88 | M&L for sand filling under floors for cushion bed to interlocking paver block all as specified and directed. |
| 89 | M&L for Preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 90 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as spd and directed. |
| 91 | M& L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and directed. |
| 92 | M&L for Formwork tochullah hoods, chajjas, troughs and similar items including edges and fair finished all as spd and directed |
| 93 | M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item). |
| 94 | M&L for Drilling & chemical anchoring of new rebars :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-16 & 20 mm dia bar - drilling length 160 to 180 mmNote : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item). |
| 95 | Supply & fixing 12 mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specified by manufacturer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA). ( The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed. |
| 96 | S&F powder coated anodised aluminium frame for windows, ventilators, grill with one or more rebates including necessary joining cleat, powder coated aluminium snap beading, screws for fixing etc. complete all as specified & directed.Note: (1) Only aluminium items to be measured.(2) Glass, wiremesh, handles to be measured & paid separately.(3) Minimum thickness of powder coating to be 50 micron. |
| 97 | S&F 4 mm thick pin headed or figured glass and glazing with oil putty in square n exc 0.5 sq. m in each pane including Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick sur rounds, any thickness or size; hacking out old putty or removing beads etc,including making good breakages in taking out and handling removing to store or stacking for reuse , complete all as specified and directed. |
| 98 | Dismantling of brick tiles or terracing single layer on roof and removal of rubbish beyond MOD land complete all as specified and directed. |
| 99 | Demolition of mud phuska on roof slabs,any thickness including cleaning of roof surfaces and removing the debris outside the MOD land not less than 1 km complete all as specified and directed. |
| 100 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as specified and directed. |
| 101 | M&L for priming roof surfaces and applying water proofing treatment over roof including preparation & cleaning of roof surface comprising of the following complete all as specified & as directed:-(a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (b) Laying 3 mm thick APP polymeric water proofing membrane of weight not less than 3.0 kg/Sqm, black finish reinforced with non woven polyester matt, with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75 mm at sides and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminous primer, complete all as per manufacturer's instruction. |
| 102 | M&L for ATT along the external wall below concrete or massonary appron using chemical emulsion @ 2.25 litres per linear meter including drilling and plugging holes etc. in apron |
| 103 | M&L for ATT treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia hpoles with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors. |
| 104 | M&L for pre-cast PCC tiles machine pressed of size 25cm x 25cm x 22 mm thick, over and including 20 mm thick screed bed in cement mortar 1:6 and joints grouted flush in cement mortar 1:3 mixed with integral water proofing compound (for screed bad and grouting of joints) as per manufacturer instruction, complete all as specified. |
| 105 | Dampness/ Moisture/ Seepage Intrusion Assessment through Inspection & Thermal Imaging Technology of Bldg No. P-6 & P-7 Single Nursing offr living at AHRR Complex (G+3), in which Ground floor is stilt parking & is having 2 quarters & other floors have total 12 quarters (04 quarters on each floor in each bldg) along with stepwise solution recommendations through a report. The inspection is to be carried out at least two times i.e. before commencement of work and after completion of work physically. The company shall also provide a room-wise excel sheet of activities to be carried out for arresting the issues observed, so that proper managementg of activity can be done during excecution (Make: MACJ/Pidilite/iCanNano). Bldg No P-6 & P-7 Specifications are as following:1. G+3 Storey (14 Qtrs in P-6 Bldg & 14 Qtrs in P-7 Bldg, Total 28 qtrs)2. Total Plinth area of both Bldgs 1646 sqm3. Area of Each Offr Qtr 36 sqm (1xRooms, 1xBathroom & 1 Hall)4. Area of Each Corridor & Staircase 14 Sqm5. Area of Stilt Parking 73 Sqm6. Area of Roof (open terrace area, Chajjas etc. ) 160 SqmNote : A. Each bidder to has to carry out the pre inspection of the above said bldg before quoting the rate for this item during any working day of the GE office.B. Tri-party agreement is to be submitted between the company, the contractor and the department for carrying out the ibid work. |
| 106 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 107 | M & L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 20 mm dia or higher as per site requirement with all fittings such as GI metal flush box of thickness 1.6 mm suitable for modular switches / sockets / fan regulators with cover plates, blanking plates, brass / cadmium plated screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- |
| 108 | (a) One light/fan/bell/exhaust fan point controlled by one switch. |
| 109 | (b) One 3 Pin socket outlet 5 Amps on Independent board. |
| 110 | (c) One 3 Pin socket outlet 5 Amps on same board. |
| 111 | (d) One light point controlled by two, two way switch |
| 112 | All as per srl item No. 2 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 16 Amp power point. |
| 113 | S & F Modular Switch 1 way 16 A, 1 Module, IP-20 complete all as specified and directed |
| 114 | S & F Modular Socket 6 / 16 A - 2/3 Pin combined 2 module, IP-20 complete all as specified and directed |
| 115 | S & F Modular Switch 1 way 6 /10 A, 1 Module,IP-20 complete all as specified and directed. |
| 116 | S & F Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module, IP-20 complete all as specified and directed. |
| 117 | S & F Modular Switch 2 way 6 / 10 A, 1 Module, IP-20 complete all as specified and directed. |
| 118 | S & F Modular fan regulator step type, 120W 2 Module complete all as specified and directed. |
| 119 | S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed. |
| 120 | S & F Modular bell push 6 A, 1 Module, IP-20 |
| 121 | S & F in replacement of Bell Ding Dong, 240 Volts complete all as specified and directed. |
| 122 | Supply and fix in replacement Modular AC Box with MCB (25A, SP) Protected Socket, with sheet steel enclosure including Top Pin of 25 A, with indicator complete all as specified and directed |
| 123 | Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top 15/16 Amp, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc, complete all as specified and directed by by Engineer-in charge. |
| 124 | Supply and fix in replacement Surface / wall mounted LED batten 20 W, luminaire made up of Extruded Aluminium Housing with PC diffuser, IP 40. The LEDs used should have a colour consistency SDCM≤5, CRI ≥ 80 and CCT 6500K, ≥ 120 lumen/watt, PF ≥0.95. The luminaire brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make / manufacturer as that of LED luminaires complete all as specified and directed |
| 125 | Supply of surface/wall mounted 10W LED batten. Luminaire made up of Extruded Aluminum Housing with PC diffuser. the luminiare should be with IP40 from dust. The LEDs used should have CRI ≥ 80 and CCT 6500K. Luminaire system efficacy of ≥ 120 lumen/watt. The luminaire shall have life class of min 50,000 burning hrs .The electronic driver used shall have a power factor ≥0.90 . Fixture must have voltage range protection from 140-270V along with inbuilt surge protection of min 2.5KV. The luminaire shall pass Insulation Resistance test @ ≥ 2MΩ. The luminaire Working Temp. range should be from 0⁰ to 50⁰C. |
| 126 | S & F of LED light Bulkhead fitting 1x9W / 1X10W,220-240 V, 50 Hz, luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, IP-65, high impact vandal resistant Polycarbonate housing with non corrosive powder coating Opal polycarbonate diffuser with high light transmittance, CCT 5700-6500 K, PF≥0.95, Surge protection of minimum 2.5 KV, THD less than 10 %, The luminaire shall have life class of min 50,000 burning hrs, complete all as specified and directed. |
| 127 | S&F surface mounting LED building security light fitting fitted in high pressure die cast aluminium housing not less than 35 W including fabrication of GI bracket 25mm dia suitable for fixing of LED light fitting duly fixed with clamps, nut bolts & washer etc. Fixture should have minimum efficacy at system level >=120 lumens/Watt, life of fixture not less than 50K Hrs,Ripple<5%,UGR<19,minimum Surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 ,THD<10% @ 240v Ac with IP 66 protection. An operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. |
| 128 | Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified and directed. |
| 129 | M & L Sub main wiring with 2 x 6 Sqmm and 1 x 6 sqmm (for earth) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including regid PVC conduit 20 mm dia or higher, complete with all conduit accessories and connected with thimble from main DB / Panel to sub DB complete all as directed.Note :1. The two run of 6 Sqmm wire, one run of 6 Sqmm wire (for earth) and 1 mtr PVC conduit pipe will be measured as one unit. |
| 130 | M & L Sub main wiring with 2 x 4 Sqmm and 1 x 4 sqmm (for earth) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including regid PVC conduit 20 mm dia or higher, complete with all conduit accessories and connected with thimble from main DB / Panel to sub DB complete all as directed.Note :1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire (for earth) and 1 mtr PVC conduit pipe will be measured as one unit. |
| 131 | S & F of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 6 way, 415 volts with bus bar rating of suitable size made of Copper, dust and vermin proof suitable for incorporation of MCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed. |
| 132 | S & F of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating of suitable size made of copper, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed. |
| 133 | S & F in replacement SPN MCB, 40 Amps capacity, 240V, 10 KA breaking capacity, C curve complete all as specified and directed |
| 134 | S & F in replacement MCB SP 40 Amps capacity, 240V, 10 KA with earth leakage protection complete all as specified and directed |
| 135 | S & F in replacement MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed |
| 136 | S & F in replacement MCCB, 415 Volt, 16kA, 4 pole, 100 Amp (Icu = 100% Ics) capacity with over load and short circuit protection and adjustable thermal overload release complete all as specified and directed |
| 137 | Take down water heater storage type of any capacity carefully and reflexing complete with new fasteners and all accessories complete all as directed |
| 138 | Taking down carefully & refixing ceiling / exhaust / wall fan of any size sealing cable end, dismantling blades & removing fan and blades deposited to MES store complete all as directed. |
| 139 | Labour for Taking down of electric meter with box of any make and type from the site and depositing it to the MES store all as specified and directed by Engr-in-charge |
| 140 | S&F of hot press moulded SMC meter box of inside dimensions 400x300x190 mm with hinged doors fixed in walls alongwith exisiting meter and making good to the disturb surfaces complete all as specified and directed. |
| 141 | M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 2 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender