Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #56819449

Tender For Maintenance Of E/M Installations At Zone A Area Under Ge (Navy) Chennai

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
12 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
1 days left
EMD
24000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maintenance Of E/M Installations At Zone A Area Under Ge (Navy) Chennai

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-Aug-2026

BOQ

Name of Work:- MAINTENANCE OF E/M INSTALLATIONS AT ZONE A AREA UNDER GE (NAVY) CHENNAI
Sl. No. Item Description
1M & L for Straight through joint kit Heat shrinkable type suitable for 1.1 KV XLPE under ground cable of size 25-35 sqmm 3.5 core all as directed.
2M & L for Straight through joint kit Heat shrinkable type suitable for 1.1 KV XLPE under ground cable of size 120-185 sqmm 3.5 core all as directed.
3Supply and fix heat shrinkable straight through cable jointing kit for 11 KV grade cable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
4Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
5Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
6Material & Labour for MCCB 250 Amps 25 KA, 4 Pole including dismentling of old one MCCB testing and commissioning complete all as specified and directed by Engineer-in-Charge.
7Supply & fixing MCB TPN 63 amps of 10 KA in existing panel with incoming and outgoing connection complete all as directed.
8Supply & fixing MCB TPN 32 amps of 10 KA in existing panel with incoming and outgoing connection complete all as directed.
9M&L for roughing old painTing from the LT panels by paint removers, cleaning with scrapes and preparing the surface and applying one coat of painting complete to LT panel with synthetic enamelled paint of existing colour and writing work for incoming and outgoing complete all as directed.
10Supply and fix Digital ammeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring.
11Supply and fix Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring.
12Supply and fix Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring and volts.
13Supply and fix CT coil 250/5 Amps with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring.
14Taking out existing LT cable off sizes up to 240 Sqmm 3/3.5 core from duct/wall/floor/ trenches and re-laying the same serviceable cable after fault rectification in existing position with supply and fixing connecting materials such as thimbles, lugs, nuts, bolts and washers as required at site all as specified and directed.
15Material and labour for shifting carefuly transformer / DG Set of capacity 100 to 500 KVA, 11000 V/415 V from one substation to another substation including disconnecting HV/LV cables, earthing connections etc and reconnecting all connections after installation complete in all respect.
16S&F Mild Steel Chequered Plate of 6 mm thick to Cable Duct Cover and 45 x 45 x 6 mm angle iron, cut in to required pieces and lifting groove and placing over angle iron complete all as specified and as directed.
17Supply & fix aluminium lugs for 50 sqmm to 70 sqmm 3.5 core cable complete all as specefied and as directed
18Supply & fix aluminium lugs for 95 sqmm to 120 sqmm 3.5 core cable complete all as specefied and as directed
19Supply & fix aluminium lugs for 240 sqmm to 300 sqmm 3.5 core cable complete all as specefied and as directed
20M & L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25x4 mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately. Please Enable Macros to View BoQ information
21M & L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25x4 mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56819449
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 12 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance Of E/M Installations At Zone A Area Under Ge (Navy) Chennai
Basic Detail
Tender No 8842/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 22 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 12 Lakhs
Tender Fee 500
EMD 24000
Exemption Available
Document List
8842GENERALPAGES.pdf
8842PS.pdf
BOQ_876698.xls
c2b95f9c-c6ef-4b5c-9cd9-868c46e158eb.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
pdf

8842GENERALPAGES.pdf

pdf

8842PS.pdf

xls

BOQ_876698.xls

html

c2b95f9c-c6ef-4b5c-9cd9-868c46e158eb.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders