Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56819437

Tender For Comprehensive Maintenance And Repair/Replacement Of Internal Wiring, Fitting & Fixtures, Dbs, Sub Main Wirings And Other Connected Accessories At G, H & Other Technical Area Under Garuda At Naval Base Under Ge (Nw) Kochi

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
35 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
0 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance And Repair/Replacement Of Internal Wiring, Fitting & Fixtures, Dbs, Sub Main Wirings And Other Connected Accessories At G, H & Other Technical Area Under Garuda At Naval Base Under Ge (Nw) Kochi

BOQ

Name of Work:- COMPREHENSIVE MAINTENANCE AND REPAIR/REPLACEMENT OF INTERNAL WIRING, FITTING & FIXTURES, DBS, SUB MAIN WIRINGS AND OTHER CONNECTED ACCESSORIES AT G, H & OTHER TECHNICAL AREA UNDER GARUDA AT NAVAL BASE UNDER GE (NW) KOCHI
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
2M&L for point wiring for one light/ fan point/exhaust fan point controlled by one 5 Amp switch with 1100 volt grade PVC insulated-unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc complete all as specified and directed. Note : Proper colour coding shall be adopted.
3All as per item No. 02 here in before but for one 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
4All as per item No. 02 here in before but for one 3 pin 5 Amp switch socket outlet on same board with complete all as specified and directed.
5M&L for point wiring for 15 Amp power point controlled by one 15 Amp switch with 1100 volt grade PVC insulated-unsheathed FRLS 2.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 2.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in & including PVC casing & capping medium grade with fittings (ISI marked) not less than 20 mm dia & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover sheet for housing/fixing switches etc complete all as specified and directed. Note : Proper colour coding to be adopted.
6M&L for point wiring for 15 Amp power point controlled by one 15 Amp switch with 1100 volt grade PVC insulated-unsheathed FRLS 4 Sq mm multi stranded copper conductor cable with continuous earth wire of 4 Sqmm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in & including PVC casing & capping medium grade with fittings (ISI marked) not less than 25 mm dia & sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover sheet for housing/fixing switches etc complete all as specified and directed. Note : Proper colour coding to be adopted.
7S&F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and directed.
8S&F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and directed.
9S&F modular socket 6Amp 2/3 pin combined 2 module complete all as specified and directed.
10S&F switch modular single pole two way 6 amp 240 volts,1 Module complete all as specified and directed.
11S&F modular socket 16Amp 2/3 pin combined 2 module complete all as specified and as directed.
12S&F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed.
13S&F bell push modular 6 Amps single module complete all as specified and directed.
14S&F bell electric ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and directed.
15S&F modular type TV Co - axial Socket out let, 1 module complete all as specified and directed.
16S&F in repair modular white cover plate with frame, but 1 module complete all as specified and directed.
17S&F in repair modular white cover plate with frame, but 2 module complete all as specified and directed.
18S&F in repair modular white cover plate with frame, but 3 module complete all as specified and directed.
19S&F in repair modular white cover plate with frame, but 4 module complete all as specified and directed.
20S&F in repair modular white cover plate with frame, but 6 module complete all as specified and directed.
21S&F in repair modular white cover plate with frame, but 8 module complete all as specified and directed.
22S&F ceiling rose 3 terminals PVC/polycarbonate, isolated body, ISI marked complete all as specified and directed.
23S&F in repair switch piano flush type, single pole, one way 6 amp 240 volts, complete all as specified and directed.
24S&F in repair switch piano flush type, single pole 16 amp 240 volts, complete all as specified and directed.
25S&F in repair socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed.
26S&F in repair socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and directed.
27S&F in repair switch socket combination 2 in1, 3 pin, 5 Amps flush type, universsal complete all as specified and directed.
28S&F in repair switch socket combination 2 in1, 3 pin, 5 and 15 Amp flush type, universsal complete all as specified and directed.
29S&F in replacement flame proof rotary switch 10 to 16 Amps complete all as specified and directed.
30S&F in replacement flame proof socket 10 to 16 Amps complete all as specified and directed.
31S&F in repair bell push flush type 5 amp AC 230 volts, single pole complete all as specified and directed.
32S&F in repair stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed.
33S&F in repair fan capacitor 2.5 MFD for ceiling fans complete all as specified and directed.
34S&F in repair capacitor 4.0 MFD for exhaust fan complete all as specified and directed.
35S&F in repair, capacitor 6.0 MFD for industrial type wall mounting fan complete all as specified and directed.
36S&F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed.
37S&F SPN enclosure with two pin and earth plug and socket complete with one MCB SP 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified and directed.
38M&L for sub main wiring with two runs of 2.5 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC concealed/surface conduit of size not below 25mm size with all fixing accessories along with one run of 2.5 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed. Note :- Two runs of 2.5 sqmm and one run of 2.5 sqmm cable as earth wire along with PVC conduit shall be measured as single unit length.
39M&L for sub main wiring with two runs of 4 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC concealed/surface conduit of size not below 25mm size with all fixing accessories along with one run of 4 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed. Note :- Two runs of 4 sqmm and one run of 4 sqmm cable as earth wire along with PVC conduit shall be measured as single unit length.
40M&L for sub main wiring with two runs of 6 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC concealed/surface conduit of size not below 25mm size with all fixing accessories along with one run of 6 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed. Note :- Two runs of 6 sqmm and one run of 6 sqmm cable as earth wire along with PVC conduit shall be measured as single unit length.
41M&L for sub main wiring with two runs of 10 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC concealed/surface conduit of size not below 25mm size with all fixing accessories along with one run of 10 sqmm copper cable as earth continuity conductor complete including taking down the old existing submain wiring complete all as specified and as directed. Note :- Two runs of 10 sqmm and one runs of 10 sqmm cable as earth along with PVC conduit shall be measured as as single unit length.
42M&L for sub main wiring with four runs of single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including not below the size of 25 mm dia concealed/surface rigid non metallic PVC conduit medium grade with fittings (ISI marked) with all accessories such as Tees, elbows, junction boxes etc, as required, fixed on surface of wall alongwith two run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion complete including taking down the old existing submain wiring complete all as specified and as directed. Note: Four runs of 6 sqmm and two runs of 6 sqmm cable as earth along with PVC conduit will be measured as one length.
43M&L for sub main wiring with four runs of single core 10 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including not below the size of 25 mm dia concealed/surface rigid non metallic PVC conduit medium grade with fittings (ISI marked) with all accessories such as Tees, elbows, junction boxes etc, as required, fixed on surface of wall alongwith two run of 10 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion complete including taking down the old existing submain wiring complete all as directed. Note: Four runs of 10 Sqmm and two runs of 10 sqmm cable as earth wire along with PVC conduit shall be measured as as single unit length.
44S&F in repair LED lights fitting 1x 22W, 230V, AC decorative box type with driver holder, 120 lum/watt including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
45S&F in repair Regal Batten for LED tube lights, single/both side connection type complete all as specified and as directed.
46S&F in repair LED tube rod 1x20 W single/both side connection type all as specified and directed in replacement of conventional tube rods, ballast etc. complete all as specified and as directed.
47S&F in repair LED light fitting mirror type with high out put diffuser 2 feet 120 lum/watt, 12 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
48S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 120 lm/W, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
49S&F in repair LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including taking down old fitting complete all as specified and as directed.
50S&F in repair round/square shape type 12 watt, 220 volts AC, 120 lm/Wattt, recessed type ceiling light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
51S&F in repair round/square shape 6 watt 220 volts AC, 100 lm/Wattt, recessed type ceiling light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
52S&F in repair 12 watt LED bulb 230 Volts, 50 Hz with min 120 lumen/watt must match with the exiting lamp holder with necessary fixtures and fittings complete all as specified and directed.
53S&F sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 4 way with 200 Amp rated bus bar complete including taking down old DBs complete all as specified and directed.
54S&F sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 8 way with 200 Amp rated bus bar complete including taking down old DBs complete all as specified and directed.
55S&F sheet metal enclosures for DBs when MCBs to used single pole & neutral (SPN) double door 240 volts, 12 way with 200 Amp rated bus bar complete including taking down old DBs complete all as specified and directed.
56S&F sheet metal enclosures for DBs when MCBs/MCCBs to be used verticle tripple pole & neutral (VTPN) double door (Optium F1+12), 415 volts, 4 way with IP-42, IK-08 protection incl 200 Amp rated copper bus bar and neutral link (ISI marked) complete including taking down old DBs complete all as specified and directed.
57S&F Sheet Metal Enclosure for MCB DB, TPN 4 Ways double door,with 200 Amps rated bus bar , having IP-43 protection including taking down of old DB complete all as specified and as directed.
58S&F 415V, 10KA 'C' curve miniature circuit breaker (MCB) of triple poles and neutral (TPN/FP) and current carrying capacity 32 Amp in the MCB DB with connection testing and commissioning complete including taking down old MCBs complete all as specified and as directed.
59S&F 415V, 10KA 'C' curve miniature circuit breaker (MCB) of triple poles (TP) and current carrying capacity 25-63Amp in the MCB DB with connection testing and commissioning complete including taking down old MCBs complete all as specified and as directed.
60S&F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral (SPN) and current carrying capacity 32 Amp in the MCB DB with connection testing and commissioning complete including taking down old MCBs complete all as specified and as directed.
61S&F 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete including taking down old MCB complete all as specified and as directed. .
62S&F MCCB 4 Pole, 415 V, adjustable type, 63 Amps with breaking capacity 16 KA duly ISI marked complete including taking down old MCCBs complete all as specified and as directed.
63S&F MCCB 4 Pole, 415 V, adjustable type, 125 Amps with breaking capacity 25 KA duly ISI marked complete including taking down old MCCBs complete all as specified and as directed.
64S&F MCCB 4 Pole, 415 V, adjustable type, 160 Amps with breaking capacity 25 KA duly ISI marked complete including taking down old MCCBs complete all as specified and as directed.
65S&F MCCB 4 Pole, 415 V, adjustable type, 200 Amps with breaking capacity 25 KA duly ISI marked complete including taking down old MCCBs complete all as specified and as directed.
66Taking down unserviceable ceiling fan of 1200/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking/heating up the motor to achieve the proper insulation resistance and re-hanging /refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun complete all as specified and directed.
67Taking down unserviceable exhaust fan of 300/250mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking/heating up the motor to achieve the proper insulation resistance and re-hanging /refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun complete all as specified and directed.
68S&F in repair exhaust fan motor for PVC type exhaust fan of size 200/250/300 mm sweep complete all as specified and directed.
69S&F in repair exhaust motor for steel body type exhaust fan of size 250/300/350 mm sweep complete all as specified and directed.
70M&L for checking of ceiling fans stability (like fan hooks, nuts, bolts, hanging rod, canopy,washer etc) and exhaust fan stability, loose connection in fans and replacement of cable from fans to ceiling rose, minor repairs to ceiling fans/exhaust fans like replacement of capacitors, cleaning and oiling etc, as required to make the fans fully functional and checking the electric connection of distribution boars, MCBs in Qtrs and tightening of all connections in DBs complete all as specified and directed.NOTE: 1. The material incorporated for completion of work like MCBs, DBs, fan capacitors, etc will be measured and paid separately under relevant item.2.The contractor should prepare a register and enter the user name with signature and submit to Engineer-in-charge.
71Material, Labour including transportation of tools for rectification of urgent nature of electrical complaints like checking of existing electrical connection for continuous electric supply including carrying out minor repairs such as changing of screws in MCBs, small pieces of wires etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, at 'L', 'M' & 'K' Area during off hours/Sundays & Holidays complete all as specified and as directed by Engineer-in-charge. NOTE :- (i) The material incorporated for completion of work if necessary will be measured and paid seperately under relevent item.(ii) The contractor should display contact number at complaint cell to register users complaint(iii)The recovery of rupees 1000 per complaints will be charged if contractor failed to attend the instipulated time period. (iv) Number of complaints may vary day to day and shall be on required basis.
72S&F in repair ceiling fan complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note : Old ceiling fans to be deposited at AGE E/M store yard.
73S&F in repair wall mounting fan 400 mm sweep, 230 V, 50 Hz, 5 star rated complete all as specified and as directed. Note : Old wall mounting fans to be deposited at AGE E/M store yard. Make : Havells model Platina Remote White or equivalent make in approved list of manufacturers.
74S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep, 1200 rpm with, blades, and frame and louvers including necessary civil work for fitment of exhaust fan as per existing site conditions complete all as specified and as directed.Note : Old exhaust fans to be deposited at AGE E/M store yard.
75S&F in repair exhaust fan plastic body heavy duty with louvers complete of sweep size 250mm, 1200 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including suitable size of cutting/opening the wall for fixing and provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and as directed. Note : Old exhaust fans to be deposited at AGE E/M store yard.
76S&F 600mm sweep, turbo force AIR Circulator (wall fan) heavy duty, single phase 230 Volts, 1440 rpm complete all as specified and as directed. Note : Old fan to be deposited at AGE E/M store yard.
77S&F factory made optipro enclosure for frame 1, made out of CRCA 1.2 mm thick, powder coated, dust and vermin proof including MCCB thermal based release adjustable type 4 pole 125 Amps, 50 Hz, 415 Volts with rupturing capacity 25 kA including testing, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and as directed.
78S&F triple pole and earth encolsure of 63 Amps, 415 Volts, with a three pin and earth plug with socket complete with one triple pole MCB complete all as specified and as directed.
79S&F rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed.
80M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c, 20 mm bore medium grade watering pipe, water funnel, 25 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and as directed by Engr-in-Charge. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
81Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections including testing complete all as specified and directed.
82Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 2 core nominal cross section in service connections including testing complete all as specified and directed.
83Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 4 core nominal cross section in service connections including testing complete all as specified and directed.
84Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 25 sq. mm 4 core nominal cross section in service connections including testing complete all as specified and directed.
85Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 50 sq. mm 3 ½ core nominal cross section including testing complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56819437
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Maintenance And Repair/Replacement Of Internal Wiring, Fitting & Fixtures, Dbs, Sub Main Wirings And Other Connected Accessories At G, H & Other Technical Area Under Garuda At Naval Base Under Ge (Nw) Kochi
Basic Detail
Tender No 8633_GE_NW
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 03 Aug 2026
Submission Date 24 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Not Available
Document List
0a8c07dc-f49d-46a4-880c-1ce8a1e8119d.html
BOQ_876656.xls
PS8533.pdf
Tender8633.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

0a8c07dc-f49d-46a4-880c-1ce8a1e8119d.html

xls

BOQ_876656.xls

pdf

PS8533.pdf

pdf

Tender8633.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders