Tender For Repair Maintenance Of Lt Panels, Servo Stablizers Mccbs Lt Cable For Lkt At Af Stn Bhowali.
Tender Value
7.92 Lakhs
Estimated cost
Bid Submission
22 Aug 2026
11 days left
EMD
15840
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nainital → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Maintenance Of Lt Panels, Servo Stablizers Mccbs Lt Cable For Lkt At Af Stn Bhowali.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar/ street light pole box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed. |
| 2 | M&L for dismanteling of of old damaged /cracked PCC coping and prepare the new coping for steel/PCC pole using PCC 1:3:6 type D-2 with 20 mm graded stone aggregate making collar above ground level on existing foundation of pole size 450x450x300 mm high and plastering with 1:4 cement sand mixer for smooth look including curing to achieve the strength and breaking/removing existing old damaged coping complete all as specified and directed. |
| 3 | S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size as followinng items:- |
| 4 | 25 sqmm 3.5 core to 70 sqmm, 3.5 core |
| 5 | 95 sqmm 3.5 core to 240 sqmm 3.5 core |
| 6 | Trimming/cutting of tree /removal of bushes/removal of vegetation growth/cutting trunk portion protruding over ground, digging out roots arround 2 mtr radius of LT panel and removal from site complete all as specified and directed. Note:- This job may be repeated after three month at the same location. |
| 7 | S&F (in replacement) following items in the existing out door/ indoor LT panels and connection with using aluminum lugs/ferrules including disconnection & connection of cable and making necessary alteration in panel/door using welding work and cutting as required for proper fixing & connection complete all as specified and directed as below :- |
| 8 | MCCB 3 Pole 63 amps rating, 16 KA breaking capacity, 415 Volt |
| 9 | MCCB 3 pole 100 amps rating, 16 KA breaking capacity with spreader at both sides |
| 10 | MCCB 3 pole150/160 amps rating, 36 KA breaking capacity with spreader at both sides |
| 11 | MCCB 3 pole 200 amps rating, 36 KA breaking capacity with spreader at both sides |
| 12 | MCCB 3 pole 250 amps rating, 36 KA breaking capacity with spreader at both sides |
| 13 | Volt meter (0 to 500 volts) anolog type with selector switch for three phase |
| 14 | Amp meter (0 to 500 amps) anolog type, with selector switch for three phase measurement. |
| 15 | CTs of existing ratio and capacity fixed in LT panels and connect with ammeter |
| 16 | Indicator lamp, LED type including 1.5 sqmm wire for connection to desired point of bus bar. |
| 17 | MCB TPN 63 amps, 'C' series, 415 volt |
| 18 | M&L for boring under road horizontally of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soil complete all as specified and directed. |
| 19 | Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs both ends of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed for following size :- (Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) |
| 20 | 25 Sqmm 4 core |
| 21 | 50 Sqmm 3.5 core |
| 22 | 95 Sqmm 3.5 core |
| 23 | Excavation in trenches in hard/dense soil not exceeding 1.50 Mtr wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed by Engr-in-Charge. |
| 24 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed. |
| 25 | Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed. |
| 26 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable i.e. total 23 cm) Note:- 18 cm punned thickness shall be taken for payment. |
| 27 | M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ laid dry flat complete all as specified and as directed. |
| 28 | M&L(in replacement) for laying of GI Pipe medium grade of 50 mm bore dia in trenches /under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and directed. |
| 29 | M & L for busbar chamber box of 1.6 mm sheet with tinned plated 04 Nos copper bars of following bus bar and following box size, factory made, suitable for pole/wall mounted including all connections with aluminum strips/lugs, glands to be provided at cable entries, powder coated paint complete all as specified and directed for the following rating:- |
| 30 | Bus bar of rating 100 amps |
| 31 | Bus bar of rating 200 amps |
| 32 | S&F MCCB 4 pole, 415 volts with suitable size of sheel metal enclosure and connection with using aluminum lugs and making arrangement to fix on wall or on PCC (1:2 :4) Block complete for the following capacity/rating:- |
| 33 | 63 amps rating, 25 KA breaking capacity with both side spreader for cable connection |
| 34 | 100 amps rating, 25 KA breaking capacity with both side spreader for cable connection |
| 35 | Supply & fixing (in replacement) copper strips 20x3 mm on porceline insulator 15 BMD type 'T' placed not more than 50 cm apart including copper nut & bolts & brazing etc. complete all as specified & directed. (Note:- Insulators will be measured and paid separately under relavent items) |
| 36 | S&F (in replacement) test point terminal block made out of gun metal or phosphorous bronze size 150x150x75 mm depth, drolled, cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete all as specified and directed. |
| 37 | S&F (in replacement) porceline insulators 15 BMD type 'T' with nut bolts / screws for fixing of aluminium strips on roof including provn of PCC of size 10cmX10cmX10cm height to avoid leakage of roof complete all as specified and directed. Please Enable Macros to View BoQ information |
| 38 | S&F (in replacement) porceline insulators 15 BMD type 'T' with nut bolts / screws for fixing of aluminium strips on roof including provn of PCC of size 10cmX10cmX10cm height to avoid leakage of roof complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender