Tender For Repair/ Maintenance Of Servo Stabilizers, Lt Panels, Mccbs Lt Cable For Mes Complex Adm Site At Af Stn Bhowali.
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Servo Stabilizers, Lt Panels, Mccbs Lt Cable For Mes Complex Adm Site At Af Stn Bhowali.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar/ street light pole box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed. |
| 2 | S&F (in replacement) following items in the existing out door/ indoor LT panels and connection with using aluminum lugs/ferrules including disconnection & connection of cable and making necessary alteration in panel/door using welding work and cutting as required for proper fixing & connection complete all as specified and directed as below :- |
| 3 | MCCB 3 Pole 63 amps rating, 16 KA breaking capacity, 415 Volt |
| 4 | MCCB 3 pole 100 amps rating, 16 KA breaking capacity with spreader at both sides |
| 5 | MCCB 4 pole150/160 amps rating, 36 KA breaking capacity with spreader at both sides |
| 6 | MCCB 4 pole 200 amps rating, 36 KA breaking capacity with spreader at both sides |
| 7 | MCCB 4 pole 250 amps rating, 36 KA breaking capacity with spreader at both sides |
| 8 | MCCB 4 pole 350 amps rating, 36 KA breaking capacity with spreader at both sides |
| 9 | Volt meter (0 to 500 volts) analog type with selector switch for three phase |
| 10 | Amp meter (0 to 500 amps) analog type, with selector switch for three phase measurement . |
| 11 | CTs of existing ratio and capacity fixed in LT panels and connect with ammeter |
| 12 | (k) Indicator lamp, LED type incl 1.5 sqmm wire for connection to desired point of bus bar. |
| 13 | MCB TPN 63 amps, 'C' series, 415 volt |
| 14 | M&L for boring under road horizontely of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soil complete all as specified and directed. |
| 15 | Disconnecting & dismentling of damaged/unserviceable cable any type /make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs both ends of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified and directed for following size :- (Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately) |
| 16 | 95 Sqmm 3.5 core |
| 17 | 16 Sqmm 4 core |
| 18 | 70 Sqmm 3.5 core |
| 19 | Excavation in trenches in hard/dense soil not exceeding 1.50 Mtr wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed. |
| 20 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and directed. |
| 21 | Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed. |
| 22 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable i.e. total 23 cm.) NOTE:- Only punned thickness of 18 cm shall be measured for payment. |
| 23 | M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat all as specified and directed. |
| 24 | M&L(in replacement) for laying of GI Pipe medium grade of 50 mm bore dia in trenches /under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and as directed. |
| 25 | Material and Labour for supply, installation, commissioning and testing of outdoor type LT panel(CPRI Approved) made out of 3.15 mm thick sheet metal, double door made out of MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incomming and outgoing cable including dismantling /taking out complete all as directed of suitable sizes for following :-Incoming (a) MCCB 250 Amps,4 pole, 35 KA adjustable type – 01 Nos (b) Ammeter 96 mm square digital type with selector switch and CT -01 set(c) Voltmeter 0-500V -01 No digital type 96 mm square with selector switch- 1 set(d) LED indicator lamp 230 volts AC Supply (R-Y-B)- 1 set (e) CTs with suitable size as per current ratingOutgoing(a) MCCB 200 Amps,4 pole, 35 KA adjustable type - 01 No (b) MCCB 100 Amps,4 pole, 25 KA adjustable type - 03 No (c) MCCB 63 Amps,4 pole, 25 KA adjustable type - 03 No Please Enable Macros to View BoQ information |
| 26 | Material and Labour for supply, installation, commissioning and testing of outdoor type LT panel(CPRI Approved) made out of 3.15 mm thick sheet metal, double door made out of MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incomming and outgoing cable including dismantling /taking out complete all as directed of suitable sizes for following :-Incoming (a) MCCB 250 Amps,4 pole, 35 KA adjustable type – 01 Nos (b) Ammeter 96 mm square digital type with selector switch and CT -01 set(c) Voltmeter 0-500V -01 No digital type 96 mm square with selector switch- 1 set(d) LED indicator lamp 230 volts AC Supply (R-Y-B)- 1 set (e) CTs with suitable size as per current ratingOutgoing(a) MCCB 200 Amps,4 pole, 35 KA adjustable type - 01 No (b) MCCB 100 Amps,4 pole, 25 KA adjustable type - 03 No (c) MCCB 63 Amps,4 pole, 25 KA adjustable type - 03 No Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender