Tender for Running maintenance Of Different L.I/Dtw Schemes At Mohanbhog R.D Block Under W.R Sub-Division , Melaghar During The Year 2026-27/Sh: Repairs Of Pump & Motor, Suction & Delivery Line Including Panel Board Equipment & Re-Winding Of Horizontal Motor & Submersible Motor. Dniet No:- 25/Ee/Wrd-Ii /2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Rewinding of Horizontal Motor suitable for centrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.a) 20HP |
| 2 | b) 25-30 HP |
| 3 | Repair and maintenance of 15 HP / 17.5 HP Motor suitablefor 7500 GPH capacity submerssible pumpset by completedismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 )conductor winding in stator & all necessary spare parts andreassembling the same including servicing of rotor &necessary trial run as per specification and direction of theEngineer-in-charge |
| 4 | Labour charge of lifting of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block as per direction of the Engineer-in-charge. |
| 5 | Labour charge for lowering & fifting fixing of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block and making necessary electrical connection with main switch /starter with motor in/c trial run for 10 hrs in two spell complete as per direction of the Engineer-in-charge. |
| 6 | Labour charge for dismentalling and overhauling of 5,000 to 20,000 GPH water lubricated vertical submesible pump after taking out shaft etc. including necessary fittings of new & existing submersible materials as per direction of the Engineer-in-charge. |
| 7 | Supplying & fitting fixing of rubber flange washer 6mm thick of approved quality as per direction of the Engineer-in-chargea) 150 mm dia |
| 8 | b) 125 mm dia |
| 9 | c) 100 mm dia |
| 10 | Supplying & fitting fixing of PVC insulated Copper Wire with allelectrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.a) 7/16 Copper Wire |
| 11 | b) 1 sqmm Multistrand Wire |
| 12 | Supplying & fitting fixing of spare parts for submersible pump 5 HP to 25 HP of approved quality as per direction of Engineer-in-Charge.a) Impeller of brass make |
| 13 | b) Motor bush (Brass make) |
| 14 | c) Sand guard |
| 15 | e) Pump bush (Brass make) |
| 16 | k) Pump column nut |
| 17 | l) Impeller key |
| 18 | Dismentaling of pump for over hauiling including greasing, glandpacking, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineer in- Charge. For LI |
| 19 | Dismentalling of motor for vernishing, heating etc. complete in/creinstallation and making necessary electrical connection with main switch / starter with motor in/c trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge. |
| 20 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality.i) 150 mm dia |
| 21 | ii) 190 mm dia |
| 22 | iii) 225 mm dia |
| 23 | Providing & fitting fixing coupling nuts & bolts (all Size)of approved quality. |
| 24 | Providing & fitting fixing coupling rubber bush (All Size)of approved quality. |
| 25 | Providing & fitting fixing coupling star bush (All Size) of approved quality.i) 150 mm dia |
| 26 | ii) 190 mm dia |
| 27 | iii) 225 mm dia |
| 28 | Providing & fitting fixing Pump Shaft of approved quality. |
| 29 | Providing & fitting fixing Shaft sleeve bush of approved quality For LIi) Cast iron (CI) |
| 30 | ii) Stainless Steel (SS) |
| 31 | Providing & fitting fixing Shaft sleeve nut of approved quality.i) Cast iron (CI) |
| 32 | ii) Stainless Steel (SS) |
| 33 | Providing & fitting fixing coupling/ impeller Key of approvedquality. Stainless Steel |
| 34 | Providing & fitting fixing Casing ring of approved quality.a) 150 mm dia, 8 mm thick |
| 35 | b) 200 mm dia, 10 mm thick |
| 36 | Providing & fitting fixing C.I.gland of approved quality. For LI |
| 37 | Providing & fitting fixing Gland nut / Stag nut 100 mm long for gland of approved quality. For LI |
| 38 | Providing & fitting fixing Lantern Ring for pump of approved quality. |
| 39 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.i) 6206 Ball bearing (TATA /SKF) |
| 40 | ii) 6305 Ball bearing (TATA /SKF) |
| 41 | iii) 6306 Ball bearing (TATA /SKF) |
| 42 | iv) 6308 Ball bearing (TATA /SKF) |
| 43 | v) 6309 Ball bearing (TATA /SKF) |
| 44 | vi) 6310 Ball bearing (TATA /SKF) |
| 45 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in charge. Internal work - Exposed on wall. I) 40 mm dia nominal bore |
| 46 | Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in - charge. i) 40 mm dia |
| 47 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i) 40 mm dia |
| 48 | ii) 125 mm dia |
| 49 | iii)150 mm dia |
| 50 | Providing & fixing of brass union joints (medium class) with the pipe line in/c testing of joints complete as per CPWD specification & direction of Engg-in-charge.i) 40 mm dia |
| 51 | Providing & fixing G.I equal Tee with the pipe line in/c testing of joints complete as per CPWD specification & direction of Engg-in-charge.i) 40 x 40 x 40 mm dia |
| 52 | Providing & fitting fixing G.I. flange (10mm wall thickness) by welding with G.I./ M.S. pipe and placing position as per specification and direction of Engineer in Charge.i) 150 mm dia |
| 53 | ii) 125 mm dia |
| 54 | iii) 100 mm dia |
| 55 | Providing and fitting fixing M.S. clamp for hose pipes with nuts & bolts complete as per relevant IS specification and direction of Engineer-in-charge.i) 150 mm dia |
| 56 | Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm. as per relevant IS specification and direction of Engineer-in-charge.i) 150 mm dia |
| 57 | Providing & fitting fixing C.I tail piece of approved quality at site of work.i) 150 mm dia |
| 58 | ii) 125 mm dia |
| 59 | Providing and fitting fixing MS Foot valve as per relevant IS specification and the direction of the Engineer-in-charge.i) 150 mm dia |
| 60 | Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality.i) C.I foot valve weight |
| 61 | ii) C.I foot valve ring |
| 62 | iii) C.I foot valve net |
| 63 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality.i) 150 mm dia |
| 64 | Welding by gas or electric plant in/c transportation of plant at site etc. complete as per direction of the Engg-In-Charge. |
| 65 | Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge.a) 125 mm dia |
| 66 | Suppling & fitting fixing of sluice valve spendle suitable for sluice valve of approved quality as per direction of the E-I-C.a) 125 mm dia |
| 67 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- Upto 300mm length. |
| 68 | Demolishing cement concrete mannualy/ by mechanical means including disposal of material with all lifts and upto 50 mtr lead etc. complete as per direction of the Engg-in-charge. A) Nominal cincrete 1:3:6 or reacher mix.(in/c equivalent design mix) |
| 69 | Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design. |
| 70 | Providing and laying in position cement concrete of specified grade excluding the cost of centering & shuttering- all work upto plinth level: I) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brick aggregate of 20 mm nominal size) |
| 71 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. |
| 72 | Installation of pump motor set including carriage of materials from Departmental store yard to site of work and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run for 10hrs. in two spell as per direction of the Engineer-in-charge. |
| 73 | Providing and fitting fixing of moving iron type, Range 0-500V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make)with selector switch as a electrical instrument of the pannelboard as per specification and direction of the Engineer-in charge. |
| 74 | Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meterdirect reading type ( L & T / AE make) with selector switchand CT coil as a electrical instrument of the pannel board asper specification and direction of the Engineer-in-charge. |
| 75 | Providing & fitting fixing Steel sheet enclosed switch Fuse unit ( Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in-Charge.a) Current range 63 Amps |
| 76 | b) Current range 200 Amps |
| 77 | Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality. |
| 78 | Providing and installation of Copper Strips of 200 Amps busbar by replacing the damaged one with necessary nuts and bolts etc. as per direction of Engg.- In - Charge. |
| 79 | Supplying & fitting fixing manually operated oil immerged starter of approved quality. A) 30 HP Osco/BCH make. |
| 80 | Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of Engg.- In - Charge.a) Stand finger |
| 81 | b) Gola finger |
| 82 | c) CT Coil |
| 83 | d) Magnet Coil |
| 84 | e) Circuit board for Osco starter of Backelite make |
| 85 | Supplying & fitting fixing of spare parts for 20/25 HP Horizontal motor.a) Motor fan |
| 86 | b) Terminal plate |
| 87 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.i) 25 HP/18.5 kw Relay range within 13-21 + 10% |
| 88 | Supplying and fitting fixing of spare contact kit , type ML 1.5/2.0/3.0/ 4.0/6.0 suitable for Fully Automatic Star Delta type Motor startar L&T BCH, Havells make as per direction of Engineer-in- Charge.i) Type ML2.0 |
| 89 | Supplying and fitting fixing of spare coil, type ML 1.5/2.0/3.0/4.0/6.0 range suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge.i) Type ML2.0 |
| 90 | Supplying and fitting fixing of Thermal overload Relay, relay range 20- 32, & 28-42, directly operated suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge |
| 91 | Supplying and fitting fixing of thermal timer type GT 200 (230/250 V, 360 V, 400/440 V, 500 V, 50 Hz for 5-18 secs range) suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge. |
| 92 | Providing & fitting fixing of pannel board of local teak wood forfitting & fixing of electrical items including 2 nos. MS angle post ( Size 50X50X6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feetX1feetX 2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engineer-in-Charge.i) Size 1.80X1.20X0.025 mtr. |
| 93 | Dismentling of pannel board by disconnection of all electricalequipments & stacking of materials & return the same to Sub Divisional store as per direction of the Engineer-in-charge. |
| 94 | Labour charge for reinstallation of all electrical equipments(dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely) on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge. |
| 95 | Dismentaling of G.I pipe including necessary earth cutting etc. &return the same to Sub-Divisional store as per direction of theEngineer-in-Charge. 125/150 mm dia |
| 96 | Dismentaling of G.I bend including necessary earth cutting etc. &return the same to Sub-Divisional store as per direction of theEngineer-in-Charge. 125/150 mm dia |
| 97 | Providing and fixing G.I. pipes medim class as per IS : 1239with latest amendment complete with G.I. fittings includingtrenching and refilling, cutting and making good the walls etc.complete as per CPWD specification and direction of theEngineer - in - chargeA. External work.i) 125 mm dia |
| 98 | ii) 150 mm dia |
| 99 | Supplying & filling of Transformer Oil in the oil tank of manually operated oil immerged starter of approved quality. |
| 100 | Supplying & fitting fixing of 63 Amps kit cut for main & sub-main switch (Male & female) |
| 101 | Supplying & fitting fixing of 200 Amps kit cut for main & sub-main swich (Male & female) |
| 102 | Providing and fixing C.I. sluice valves ( with cap) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately) as per CPWD specification and direction of the Engineer - in - charge.i) 125 mm diameter, PN-1.0 |
| 103 | ii) 150 mm diameter, PN-1.0 |
| 104 | iii)200 mm dia PN-1.0 |
| 105 | Making road crossing by horizontal boring for smooth layingof UPVC / CI / DI / GI pipes etc. of required dia complete asper specification and the direction of the Engineer-in-chargeBy manual means |
| 106 | Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-inChargei) 150 mm dia nominal bore (medium) |
| 107 | ii) 125 mm dia nominal bore (medium) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender