Housing Urban and Rular Development Government Departments Closing in 7 days TDR #56818959

Tender For Running maintenance Of Different L.I/Dtw Schemes At Mohanbhog R.D Block Under W.R Sub-Division , Melaghar During The Year 2026-27/Sh: Repairs Of Pump & Motor, Suction & Delivery Line Including Panel Board Equipment & Re-Winding Of Horizont

Issued by Government Departments · tripura, Tripura
Tender Value
9.45 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
7 days left
EMD
18900
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Running maintenance Of Different L.I/Dtw Schemes At Mohanbhog R.D Block Under W.R Sub-Division , Melaghar During The Year 2026-27/Sh: Repairs Of Pump & Motor, Suction & Delivery Line Including Panel Board Equipment & Re-Winding Of Horizontal Motor & Submersible Motor. Dniet No:- 25/Ee/Wrd-Ii /2026-27

BOQ

Name of Work:- Running mtc. of different L.I/DTW schemes at Mohanbhog R.D Block under W.R Sub-Division , Melaghar during the year 2026-27/SH: Repairs of pump & motor, suction & delivery line including panel board equipment & re-winding of horizontal motor & submersible motor. DNIeT No:- 25/EE/WRD-II /2026-27
Sl. No. Item Description
1Rewinding of Horizontal Motor suitable for centrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.a) 20HP
2b) 25-30 HP
3Repair and maintenance of 15 HP / 17.5 HP Motor suitablefor 7500 GPH capacity submerssible pumpset by completedismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 )conductor winding in stator & all necessary spare parts andreassembling the same including servicing of rotor &necessary trial run as per specification and direction of theEngineer-in-charge
4Labour charge of lifting of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block as per direction of the Engineer-in-charge.
5Labour charge for lowering & fifting fixing of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block and making necessary electrical connection with main switch /starter with motor in/c trial run for 10 hrs in two spell complete as per direction of the Engineer-in-charge.
6Labour charge for dismentalling and overhauling of 5,000 to 20,000 GPH water lubricated vertical submesible pump after taking out shaft etc. including necessary fittings of new & existing submersible materials as per direction of the Engineer-in-charge.
7Supplying & fitting fixing of rubber flange washer 6mm thick of approved quality as per direction of the Engineer-in-chargea) 150 mm dia
8b) 125 mm dia
9c) 100 mm dia
10Supplying & fitting fixing of PVC insulated Copper Wire with allelectrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.a) 7/16 Copper Wire
11b) 1 sqmm Multistrand Wire
12Supplying & fitting fixing of spare parts for submersible pump 5 HP to 25 HP of approved quality as per direction of Engineer-in-Charge.a) Impeller of brass make
13b) Motor bush (Brass make)
14c) Sand guard
15e) Pump bush (Brass make)
16k) Pump column nut
17l) Impeller key
18Dismentaling of pump for over hauiling including greasing, glandpacking, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineer in- Charge. For LI
19Dismentalling of motor for vernishing, heating etc. complete in/creinstallation and making necessary electrical connection with main switch / starter with motor in/c trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge.
20Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality.i) 150 mm dia
21ii) 190 mm dia
22iii) 225 mm dia
23Providing & fitting fixing coupling nuts & bolts (all Size)of approved quality.
24Providing & fitting fixing coupling rubber bush (All Size)of approved quality.
25Providing & fitting fixing coupling star bush (All Size) of approved quality.i) 150 mm dia
26ii) 190 mm dia
27iii) 225 mm dia
28Providing & fitting fixing Pump Shaft of approved quality.
29Providing & fitting fixing Shaft sleeve bush of approved quality For LIi) Cast iron (CI)
30ii) Stainless Steel (SS)
31Providing & fitting fixing Shaft sleeve nut of approved quality.i) Cast iron (CI)
32ii) Stainless Steel (SS)
33Providing & fitting fixing coupling/ impeller Key of approvedquality. Stainless Steel
34Providing & fitting fixing Casing ring of approved quality.a) 150 mm dia, 8 mm thick
35b) 200 mm dia, 10 mm thick
36Providing & fitting fixing C.I.gland of approved quality. For LI
37Providing & fitting fixing Gland nut / Stag nut 100 mm long for gland of approved quality. For LI
38Providing & fitting fixing Lantern Ring for pump of approved quality.
39Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.i) 6206 Ball bearing (TATA /SKF)
40ii) 6305 Ball bearing (TATA /SKF)
41iii) 6306 Ball bearing (TATA /SKF)
42iv) 6308 Ball bearing (TATA /SKF)
43v) 6309 Ball bearing (TATA /SKF)
44vi) 6310 Ball bearing (TATA /SKF)
45Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in charge. Internal work - Exposed on wall. I) 40 mm dia nominal bore
46Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in - charge. i) 40 mm dia
47Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i) 40 mm dia
48ii) 125 mm dia
49iii)150 mm dia
50Providing & fixing of brass union joints (medium class) with the pipe line in/c testing of joints complete as per CPWD specification & direction of Engg-in-charge.i) 40 mm dia
51Providing & fixing G.I equal Tee with the pipe line in/c testing of joints complete as per CPWD specification & direction of Engg-in-charge.i) 40 x 40 x 40 mm dia
52Providing & fitting fixing G.I. flange (10mm wall thickness) by welding with G.I./ M.S. pipe and placing position as per specification and direction of Engineer in Charge.i) 150 mm dia
53ii) 125 mm dia
54iii) 100 mm dia
55Providing and fitting fixing M.S. clamp for hose pipes with nuts & bolts complete as per relevant IS specification and direction of Engineer-in-charge.i) 150 mm dia
56Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm. as per relevant IS specification and direction of Engineer-in-charge.i) 150 mm dia
57Providing & fitting fixing C.I tail piece of approved quality at site of work.i) 150 mm dia
58ii) 125 mm dia
59Providing and fitting fixing MS Foot valve as per relevant IS specification and the direction of the Engineer-in-charge.i) 150 mm dia
60Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality.i) C.I foot valve weight
61ii) C.I foot valve ring
62iii) C.I foot valve net
63Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality.i) 150 mm dia
64Welding by gas or electric plant in/c transportation of plant at site etc. complete as per direction of the Engg-In-Charge.
65Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge.a) 125 mm dia
66Suppling & fitting fixing of sluice valve spendle suitable for sluice valve of approved quality as per direction of the E-I-C.a) 125 mm dia
67Providing and fixing MS bolts including nuts and washers complete as per standard design:- Upto 300mm length.
68Demolishing cement concrete mannualy/ by mechanical means including disposal of material with all lifts and upto 50 mtr lead etc. complete as per direction of the Engg-in-charge. A) Nominal cincrete 1:3:6 or reacher mix.(in/c equivalent design mix)
69Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design.
70Providing and laying in position cement concrete of specified grade excluding the cost of centering & shuttering- all work upto plinth level: I) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brick aggregate of 20 mm nominal size)
71Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.
72Installation of pump motor set including carriage of materials from Departmental store yard to site of work and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run for 10hrs. in two spell as per direction of the Engineer-in-charge.
73Providing and fitting fixing of moving iron type, Range 0-500V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make)with selector switch as a electrical instrument of the pannelboard as per specification and direction of the Engineer-in­ charge.
74Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meterdirect reading type ( L & T / AE make) with selector switchand CT coil as a electrical instrument of the pannel board asper specification and direction of the Engineer-in-charge.
75Providing & fitting fixing Steel sheet enclosed switch Fuse unit ( Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in-Charge.a) Current range 63 Amps
76b) Current range 200 Amps
77Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality.
78Providing and installation of Copper Strips of 200 Amps busbar by replacing the damaged one with necessary nuts and bolts etc. as per direction of Engg.- In - Charge.
79Supplying & fitting fixing manually operated oil immerged starter of approved quality. A) 30 HP Osco/BCH make.
80Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of Engg.- In - Charge.a) Stand finger
81b) Gola finger
82c) CT Coil
83d) Magnet Coil
84e) Circuit board for Osco starter of Backelite make
85Supplying & fitting fixing of spare parts for 20/25 HP Horizontal motor.a) Motor fan
86b) Terminal plate
87Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.i) 25 HP/18.5 kw Relay range within 13-21 + 10%
88Supplying and fitting fixing of spare contact kit , type ML 1.5/2.0/3.0/ 4.0/6.0 suitable for Fully Automatic Star Delta type Motor startar L&T BCH, Havells make as per direction of Engineer-in- Charge.i) Type ML2.0
89Supplying and fitting fixing of spare coil, type ML 1.5/2.0/3.0/4.0/6.0 range suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge.i) Type ML2.0
90Supplying and fitting fixing of Thermal overload Relay, relay range 20- 32, & 28-42, directly operated suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge
91Supplying and fitting fixing of thermal timer type GT 200 (230/250 V, 360 V, 400/440 V, 500 V, 50 Hz for 5-18 secs range) suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge.
92Providing & fitting fixing of pannel board of local teak wood forfitting & fixing of electrical items including 2 nos. MS angle post ( Size 50X50X6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feetX1feetX 2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engineer-in-Charge.i) Size 1.80X1.20X0.025 mtr.
93Dismentling of pannel board by disconnection of all electricalequipments & stacking of materials & return the same to Sub Divisional store as per direction of the Engineer-in-charge.
94Labour charge for reinstallation of all electrical equipments(dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely) on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge.
95Dismentaling of G.I pipe including necessary earth cutting etc. &return the same to Sub-Divisional store as per direction of theEngineer-in-Charge. 125/150 mm dia
96Dismentaling of G.I bend including necessary earth cutting etc. &return the same to Sub-Divisional store as per direction of theEngineer-in-Charge. 125/150 mm dia
97Providing and fixing G.I. pipes medim class as per IS : 1239with latest amendment complete with G.I. fittings includingtrenching and refilling, cutting and making good the walls etc.complete as per CPWD specification and direction of theEngineer - in - chargeA. External work.i) 125 mm dia
98ii) 150 mm dia
99Supplying & filling of Transformer Oil in the oil tank of manually operated oil immerged starter of approved quality.
100Supplying & fitting fixing of 63 Amps kit cut for main & sub-main switch (Male & female)
101Supplying & fitting fixing of 200 Amps kit cut for main & sub-main swich (Male & female)
102Providing and fixing C.I. sluice valves ( with cap) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately) as per CPWD specification and direction of the Engineer - in - charge.i) 125 mm diameter, PN-1.0
103ii) 150 mm diameter, PN-1.0
104iii)200 mm dia PN-1.0
105Making road crossing by horizontal boring for smooth layingof UPVC / CI / DI / GI pipes etc. of required dia complete asper specification and the direction of the Engineer-in-chargeBy manual means
106Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-inChargei) 150 mm dia nominal bore (medium)
107ii) 125 mm dia nominal bore (medium) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56818959
AUTHORITY Government Departments
TENDER VALUE 9.45 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Running maintenance Of Different L.I/Dtw Schemes At Mohanbhog R.D Block Under W.R Sub-Division , Melaghar During The Year 2026-27/Sh: Repairs Of Pump & Motor, Suction & Delivery Line Including Panel Board Equipment & Re-Winding Of Horizontal Motor & Submersible Motor. Dniet No:- 25/Ee/Wrd-Ii /2026-27
Basic Detail
Tender No 25/EE/WRD-II/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 03 Aug 2026
Submission Date 12 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 9.45 Lakhs
Tender Fee 1000
EMD 18900
Exemption Not Available
Document List
BOQ_76679.xls
DnitMBG.pdf
f2041490-4d25-47a7-afb7-abd7d051aa92.html
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_76679.xls

pdf

DnitMBG.pdf

html

f2041490-4d25-47a7-afb7-abd7d051aa92.html

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders