Supply Of OESOPHAGEAL METALSTENT-FULLY COVERED REMOVABLE STENT SHOULD HAVE A COAXIAL DELIVERY SYSTEM WITH 25-30 MM FLARE, 20-25 MM BODY AND LENGTHS 8 OR 10 OR 12 OR 15CM. IT SHOULD BE RECONSTRAINABLE EVEN AFTER 75% DEPLOYMENT., OESOPHAGEAL VARICEAL B
Tender Overview
Project Description
Supply Of oesophageal metalstent-fully covered removable stent should have a coaxial delivery system with 25-30 mm flare, 20-25 mm body and lengths 8 or 10 or 12 or 15cm. it should be reconstrainable even after 75% deployment., oesophageal variceal bleed stent: 1. it should contains fully covered self expandable oesophageal stent with delivery system, guide wire and 50ml plastic syringe. 2. stent should made up of durable silicon and should have flaresdiameter 30mm, body diameter 25mm, nominal length 135mm. 3. delivery system should have active length 60cm and outer diameter 28/20 f. 4. guide wire should have 0.035inch (0.89mm)/260cm ultra stiff, oesophageal metal stent-partially covered stent should have 20-23 mm flare, 18-20 mm body and lengths 10 or 12 or 15cm oesophageal stent though the scope delivery system: should be a) preloaded in 10.5fr fully/partially silicone covered esophageal stent. b) 4ro marker at both ends and 2 in the middle. c) stent diameter 18mm and flare diameter 24mm. d) stent length 6,8,10 and 12cm., , srphc82336405-oesophageal metal stent-fully covered removable stent should have a co axial delivery system with 25-30 mm flare, 20-25 mm body and lengths 8 or 10 or 12 or 15cm. it should be reconstrainable even after 75% deployment. ] , srphc82336410-oesophageal metal stent-partially covered stent should have 20-23 mm fl are, 18-20 mm body and lengths 10 or 12 or 15cm. ] , srphc82336420-oesophageal variceal bleed stent: 1. it should contains fully covered sel f expandable oesophageal stent with delivery system, guide wire and 50ml plastic syringe. 2. stent sh ould made up of durable silicon and should have flares diameter 30mm, body diameter 25mm, nominal length 135mm. 3. delivery system should have active length 60cm and outer diameter 28/20 f. 4. guide wire should have 0.035inch (0.89mm)/260cm ultra stiff. ] , srphc82336415-oesophageal stent though the scope delivery system: should be a) preloa ded in 10.5fr fully/partially silicone covered esophageal stent. b) 4ro marker at both ends and 2 in t he middle. c) stent diameter 18mm and flare diameter 24mm. d) stent length 6,8,10 and 12cm. ]
BOQ
| Sl. No. | Item Description |
|---|---|
| 1 | SRPHC82336405-OESOPHAGEAL METAL STENT-FULLY COVERED REMOVABLE STENT SHOULD HAVE A CO AXIAL DELIVERY SYSTEM WITH 25-30 MM FLARE, 20-25 MM BODY AND LENGTHS 8 OR 10 OR 12 OR 15CM. IT SHOULD BE RECONSTRAINABLE EVEN AFTER 75% DEPLOYMENT. ] |
| 2 | SRPHC82336410-OESOPHAGEAL METAL STENT-PARTIALLY COVERED STENT SHOULD HAVE 20-23 MM FL ARE, 18-20 MM BODY AND LENGTHS 10 OR 12 OR 15CM. ] |
| 3 | SRPHC82336420-OESOPHAGEAL VARICEAL BLEED STENT: 1. IT SHOULD CONTAINS FULLY COVERED SEL F EXPANDABLE OESOPHAGEAL STENT WITH DELIVERY SYSTEM, GUIDE WIRE AND 50ML PLASTIC SYRINGE. 2. STENT SH OULD MADE UP OF DURABLE SILICON AND SHOULD HAVE FLARES DIAMETER 30MM, BODY DIAMETER 25MM, NOMINAL LENGTH 135MM. 3. DELIVERY SYSTEM SHOULD HAVE ACTIVE LENGTH 60CM AND OUTER DIAMETER 28/20 F. 4. GUIDE WIRE SHOULD HAVE 0.035INCH (0.89MM)/260CM ULTRA STIFF. ] |
| 4 | SRPHC82336415-OESOPHAGEAL STENT THOUGH THE SCOPE DELIVERY SYSTEM: SHOULD BE A) PRELOA DED IN 10.5FR FULLY/PARTIALLY SILICONE COVERED ESOPHAGEAL STENT. B) 4RO MARKER AT BOTH ENDS AND 2 IN T HE MIDDLE. C) STENT DIAMETER 18MM AND FLARE DIAMETER 24MM. D) STENT LENGTH 6,8,10 AND 12CM. ] |