Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56812670

Tender For Addition/ Alteration/ Conversion Of Lt Overhead Conductor To Ug Cable And Connected Works At Jodhpur Military Station

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
6.50 Crore
Estimated cost
Bid Submission
31 Aug 2026
19 days left
EMD
6.50 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addition/ Alteration/ Conversion Of Lt Overhead Conductor To Ug Cable And Connected Works At Jodhpur Military Station

BOQ

Name of Work:- ADDITION/ ALTERATION/ CONVERSION OF LT OVERHEAD CONDUCTOR TO UG CABLE AND CONNECTED WORKS AT JODHPUR MILITARY STATION
Sl. No. Item Description
1Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 300 sq mm 3.5 core complete all as specified and directed.
2Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 240 sq mm 3.5 core complete all as specified and directed.
3Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 185 sq mm 3.5 core complete all as specified and directed.
4Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 120 sq mm 3.5 core complete all as specified and directed.
5Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 150 sq mm 3.5 core complete all as specified and directed.
6Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 95 sq mm 3.5 core complete all as specified and directed.
7Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 70 sq mm 3.5 core complete all as specified and directed.
8Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 50 sq mm 3.5 core complete all as specified and directed.
9Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 35 sq mm 3.5 core complete all as specified and directed.
10Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 25 sq mm 4 core complete all as specified and directed.
11Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 16 sq mm 4 core complete all as specified and directed.
12Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 10 sq mm 4 core complete all as specified and directed. Note for Ser Items Nos 1.00 to 12.00 :- Contractor may be visit the site and location before quoting the rate and cable should be CTL tested from approved govt lab/Jodhpur discom lab. Test certificate to be provided.
13Earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x 6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2020 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata including PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site complete all as specified and directed.Note :- GI strip 32 mm x 6 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
14Dismantling of unserviceable ACSR conductor of any type and size from existing poles at various location at site complete all as specified and directed.
15Dismantling of cross arms (Clamp, nut bolts ),care fully from site complete all as specified and directed.
16Dismantling of insulators any type any size from existing poles complete all as specified and directed.
17Taking out serviceable LT cable of any type and size for re-use and relaying in ground/along wall at site complete all as specified and directed.Note : Earth work shall be measured and paid separately of relavent items and, sand & PCC covers/stone slab shall reused all as directed.
18Supply and fixing of security light junction boxes of dimension 240×130×110 mm, with shockproof, rustproof, termite resistant, weather proof, cable entry from bottom, pole mounting arrangement along with 3 phase 4 wire 100 amps almunium busbar with insulators and MCB SP-0.5 amps rating with including Cable Glands input & output, lugs, conforming to IP 65 etc complete all as specified and directed.
19Supply and fixing of three core copper wire 1.5 sqmm FRSH PVC insulated copper conductor, cable in surface/ recessed in PVC conduit as required inclusive of all tees, bends, elbows. Reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, MS clamps for fixing with pole etc of size 25 mm dia complete all as specified and directed.
20Dismantling of stay assembly complete all as specified and directed.
21Supply and fixing of cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 / 4 core XLPE, armoured, Al conductor cable of size 50 sqmm complete all as specified and directed.
22Supply and fixing of cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 / 4 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and directed.
23Supply and fixing of cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 / 4 core XLPE, armoured, Al conductor cable of size 150 sqmm complete all as specified and directed.
24Supply and fixing of cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 / 4 core XLPE, armoured, Al conductor cable of size 185 sqmm complete all as specified and directed.
25Supply and fixing of cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 / 4 core XLPE, armoured, Al conductor cable of size 240 sqmm complete all as specified and directed.
26Supply and fixing of cable jointing kit for 1.1 KV grade cable for end joint indoor type complete with Jointing material heat Shrink type and accessories suitable for 3.5 / 4 core XLPE, armoured, Al conductor cable of size 50 sqmm complete all as specified and directed.
27All as per Item No 26.00 above but size of cable 95 sqmm 3.5/4 core
28All as per Item No 26.00 above but size of cable 120 sqmm 3.5/4 core
29All as per Item No 26.00 above but size of cable 150 sqmm 3.5/4 core
30All as per Item No 26.00 above but size of cable 185 sqmm 3.5/4 core
31All as per Item No 26.00 here-in-before but size of cable 240 sqmm 3.5/4 core
32Material and labour Cement concrete (1:2:4) type B -1 using 20 mm graded stone aggregate for pedestal of poles / copping / road cutting filling / pcc cutting filling including necessary frame work ,fair finishing to exposed surfaces using extra cement complete all as specified and directed.
33M&L for GI tubing 40 mm dia light grade (ISI marked) with all fitting /accessories for protection of cable on pole/wall and under road crossing including clamps, nuts bolts etc complete all as specified and directed.
34M&L for GI tubing 50 mm dia light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nuts bolts etc complete all as specified and directed.
35M&L for GI tubing 80 mm dia light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nuts bolts etc complete all as specified and directed.
36M&L for GI tubing 100 mm dia light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nuts bolts etc complete all as specified and directed.
37Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 1/ HB
38(A) IN COMING(a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.(c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No.(B) OUT GOING(a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -09 Nos(b)street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
39Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 2/ HB
40(A) IN COMING(a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.(c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 63 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 Nos (b) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -09 Nos
41Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1200x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 3,28 / HB
42(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -03 Nos
43Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 6,7,27,30 / HB
44(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -06 Nos
45Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 5/ HB
46(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -08 Nos
47Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 8,15,17,19,23,25 / HB
48(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -06 Nos (b) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magneticadjustable release type(Icu=Ics=100%) -01 No
49Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1200x1000x450mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 9,13,14,16,18,20,21,22,24,26 / HB
50(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -06 Nos
51Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 29, 4 / HB
52(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -06 Nos (c) street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
53Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel 11 / HB
54(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -05 Nos (b) MCCB 4 Pole 415 Volts 16 KA, 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No
55Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1200x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 12 / HB
56(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%)-04 Nos
57Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 10 /HB
58(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 125 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%)-06 Nos (b) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
59Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 21A/ HB
60(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.(c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -02 No (b) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%)-03 Nos (c) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
61Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. MPA / HB
62(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (c) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
63Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 1,2,11,12,16 / SHIK
64(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -06 Nos
65Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel 3,6 / SHIK
66(A) IN COMING(a) MCCB 4 Pole 415 Volts 16 KA 63 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 Nos (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -04 Nos
67Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel 4,10 / SHIK
68(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -05 Nos
69Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 5 / SHIK
70(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -10 Nos
71Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 7 / SHIK
72(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -11 Nos
73Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following : - Panel No. 17,18/SHIK
74(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -12 Nos
75Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 21 / SHIK
76(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 No (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -10 No
77Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No.8,19/SHIK
78(A) INCOMING(a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
79Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 9,15/SHIK
80(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -09 Nos Make : Legrand /Indoasian/ABB (b) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
81Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 13/SHIK
82(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -09 Nos Make : Legrand /Indoasian/ABB
83Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 14/ SHIK
84(a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b)MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -09 Nos Make : Legrand /Indoasian/ABB
85Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 20/ SHIK
86(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a)MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos Make : Legrand /Indoasian/ABB
87Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 22/ SHIK
88(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos Make : Legrand /Indoasian/ABB
89Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel MP2/SHIK
90(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 No (c) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 No
91Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 1/ 73 ASC
92(A) IN COMING (a) MCCB 4 Pole 415 Volts 25 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 25 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos (c) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
93Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 2/ 73 ASC
94(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos
95Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1200x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 3 / 73 ASC
96(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -03 Nos Make : Legrand /Indoasian/ABB
97Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 4 / 73 ASC
98(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -03 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No
99Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- P1(FOL DEPOT)
100(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) Change over switch 300A 4P 414V AC SS Enclosure Extened handle-01 No (c) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (d) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (TO P2) (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -03 No (TO KSP1,KSP2,KSP3) (c) MCCB 4 Pole 415 Volts 16 KA 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -03 No (TO SLT1,SLT2,POST1) (d) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
101Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- P2(FOL DEPOT)
102(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amps rating thermal magnetic adjustable release type(Icu=Ics=100%) -02 No (TO OFFICE DB,P5) (b) MCCB 4 Pole 415 Volts 25 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (TO P3)
103Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- P3(FOL DEPOT)
104(A) IN COMING (a) MCCB 4 Pole 415 Volts 25 KA 100 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING(a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (TO P4) (b) MCCB 4 Pole 415 Volts 16 KA 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -02 No (TO POST 3,FIRE STN)
105Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- P4(FOL DEPOT)
106(A) IN COMING(a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -02 No(TO POST2, WELDING STN)
107Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- P5(FOL DEPOT)
108(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) -02 No (TO HM,SL)
109Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 2000x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 1 / ALSS1
110(a)MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 40 Amp rating thermal magnetic release type(Icu=Ics=100%) -08 No Make : Legrand /Indoasian/ABB
111Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 2 / ALSS1
112(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos Make : Legrand /Indoasian/ABB
113Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 3,11 / ALSS1
114(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos (b) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
115Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 4,7 / ALSS1
116(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos (b) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
117Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 5,15 / ALSS1
118(a) MCCB 4 Pole 415 Volts 36 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
119Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 2000x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 15 / ALSS4
120(a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -12 Nos
121Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 6, 8, 16,17/ ALSS1
122(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos Make : Legrand /Indoasian/ABB
123Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 9,12 / ALSS1
124(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -01 Nos (b) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic release type(Icu=Ics=100%) -04 No Make : Legrand /Indoasian/ABB
125Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 10,13 / ALSS1
126(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -03 Nos Make : Legrand /Indoasian/ABB
127Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 14 / ALSS1
128(a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos (b) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
129Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 1 / ALSS2
130(a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (c) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
131Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1100x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 2,4A,14 / ALSS2
132(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type (Icu=Ics=100%) -01 NoMake : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos
133Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following- Panel No. 3 / ALSS2
134(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 225 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -08 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
135Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 4 / ALSS2
136(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos Make : Legrand /Indoasian/ABB
137Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 2000x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 5 / ALSS2
138(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -09 Nos (b) MCCB 4 Pole 415 Volts 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -01 Nos (c) MCCB 4 Pole 415 Volts 16 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No
139Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 6 / ALSS2
140(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos (b) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
141Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 7,9A,13 / ALSS2
142(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos Make : Legrand /Indoasian/ABB
143Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 8 / ALSS2
144(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 225 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -01 Nos (b) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos Make : Legrand /Indoasian/ABB
145Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 9 / ALSS2
146(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos Make : Legrand /Indoasian/ABB
147Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 10 / ALSS2
148(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -08 Nos (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -01 Nos Make : Legrand /Indoasian/ABB
149Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 11 / ALSS2
150(a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos Make : Legrand /Indoasian/ABB
151Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 2000x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 12 / ALSS2
152(a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -09 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (c) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
153Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 1 / ALSS3
154(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens.(B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -01 Nos (b) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -01 Nos (c) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic release type(Icu=Ics=100%) -07 No Make : Legrand /Indoasian/ABB (d) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
155Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 2 / ALSS3
156(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos Make : Legrand /Indoasian/ABB
157Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 3 / ALSS3
158(a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
159Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 4,6,8 / ALSS3
160(a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -03 Nos Make : Legrand /Indoasian/ABB
161Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 5 / ALSS3
162(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (c) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos
163Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1300x1000x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following- Panel No. 7 / ALSS3
164(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -03 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
165Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 9 / ALSS3
166(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos Make : Legrand /Indoasian/ABB
167Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 10 / ALSS3
168(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos Make : Legrand /Indoasian/ABB
169Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 2000x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 11,14 / ALSS3
170(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -10 Nos (b) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
171Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 12,19 / ALSS3
172(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos (b) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
173Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 13,20 / ALSS3
174(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -08 Nos Make : Legrand /Indoasian/ABB
175Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 15 / ALSS3
176(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 NoMake : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -08 Nos (b) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No
177Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 16 / ALSS3
178(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos
179Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 17 / ALSS3
180(a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
181Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 18 / ALSS3
182(a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos Make : Legrand /Indoasian/ABB
183Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 1 / ALSS4
184(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 125 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos Make : Legrand /Indoasian/ABB
185Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 2,9 / ALSS4
186(a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -08 Nos Make : Legrand /Indoasian/ABB (b) Street light timer switch using digital timer switch for switching of street lights based on timing set manually on digital timer - 01Nos
187Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following- Panel No. 3,7 / ALSS4
188(a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos Make : Legrand /Indoasian/ABB
189Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 4 / ALSS4
190(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos
191Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 5 / ALSS4
192(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 225 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -05 Nos Make : Legrand /Indoasian/ABB (b) MCCB 4 Pole 415 Volts 16 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (c) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
193Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 6 / ALSS4
194(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -06 Nos Make : Legrand /Indoasian/ABB
195Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 8 / ALSS4
196(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -07 Nos Make : Legrand /Indoasian/ABB
197Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following- Panel No. 10 / ALSS4
198(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 400 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -3 Nos (b) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -02 No (c) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
199Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the followin:- Panel No. 11 / ALSS4
200(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -08 Nos Make : Legrand /Indoasian/ABB
201Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1500x1200x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the followin:- Panel No. 12 / ALSS4
202(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -04 Nos (b) MCCB 4 Pole 415 Volts 16 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB
203Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 1800x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 13 / ALSS4
204(A) IN COMING (a) MCCB 4 Pole 415 Volts 16 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No Make : Legrand /Indoasian/ABB (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -12 Nos Make : Legrand /Indoasian/ABB
205Supply, install, testing and commissioning CPRI approved of outdoor cubical type LT Panel board, gable roof, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars of suitable rating duly insulated by insulation of RYB colour on SMC insulators with short circuit withstand capacity 35 MVA. The panels shall be factory made, double door made outer side of 3.15 mm thick and inner shall be of 2.00 mm thick MS Sheet totally enclosed of size not less than 2000x1500x450 mm and dust, weather, vermin and rust proof front operated, front and rear opening with locking arrangement. The bootom base chanal of MS angle section not less than 100x50x5mm. Entire panal shall have common aluminimum earth bar of size 25x5 mm at the rear with two nos earth stad, solid connection from main bas bar to switch gears with required size of bus bar and controlling wiring with minimum 1.5 sqmm pvc insulated copper conductor cable. The ground clearanc should be minimum 600 mm. MS angle section 50x 50x6 mm frame with front & back openable double door system lockable / opnable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement and should be of IP 54 and complete all as directed by Engr-in-charge and comprising of the following:- Panel No. 14 / ALSS4
206(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -10 Nos Make : Legrand /Indoasian/ABB Please Enable Macros to View BoQ information
207(A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 320 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy PF,KWH, KVAH, CL-1.0 rating - 01 NoL&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (a) MCCB 4 Pole 415 Volts 40 Amp rating thermal magnetic adjustable release type(Icu=Ics=100%) rating -10 Nos Make : Legrand /Indoasian/ABB Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56812670
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6.50 Crore
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition/ Alteration/ Conversion Of Lt Overhead Conductor To Ug Cable And Connected Works At Jodhpur Military Station
Basic Detail
Tender No 800647/JODH/E8
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 03 Aug 2026
Submission Date 31 Aug 2026
Open Date 07 Sep 2026
Finance
Tender Value 6.50 Crore
Tender Fee 3000
EMD 6.50 Lakhs
Exemption Available
Document List
bf96e819-6290-4d78-8631-d6559e0ea4ea.html
BOQ_876679.xls
TENDERDOCUMENTS.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

bf96e819-6290-4d78-8631-d6559e0ea4ea.html

xls

BOQ_876679.xls

pdf

TENDERDOCUMENTS.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders