Tender For Special Repair Works To Drivers Rest Room Including Washrooms (T-9, T-9A) At Mt Pool And Provision Of Shed At Main Gate (Churulan Gate) (P-02) At Nsry (K) At Naval Base Under Ge(Nw) Kochi
Tender Value
43 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
0 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair Works To Drivers Rest Room Including Washrooms (T-9, T-9A) At Mt Pool And Provision Of Shed At Main Gate (Churulan Gate) (P-02) At Nsry (K) At Naval Base Under Ge(Nw) Kochi
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed. |
| 2 | Dismantling plain or corrugated steel sheeting any gauge, thickness complete in roofing complete all as specified and as directed. |
| 3 | Dismantling battens for tiles, shingles, etc of any size exceeding 15cm spacing including tilting fillets complete all as specified and as directed. |
| 4 | Dismantling timber boarding any description fixed in any position with nails complete all as specified and as directed. |
| 5 | Dismantling timber scantiling 40 Sqcm and over in section unframed work in any position complete all as specified and as directed. |
| 6 | Dismantling timber scantlings under 40 Sq cm in section for unframed work in fillets, rails, posts, rafters, purlins etc, in unframed works complete all as specified and as directed. |
| 7 | M&L for lInd class hard wood plain fillets square, rectangular or triangular in section clean sawn secured with nails etc of sectional area exc 3 Sqcm and n.exc 6 Sqcmcomplete all as specified and directed. |
| 8 | M&L for 2nd class hard wood in scantling clean sawn fixed as in purlins, rafters, etc in roof complete all as specified and directed. |
| 9 | M&L for IInd class hard wood boarding clean sawn with butt joints, 20mm thick as in soffits of gutter, eves board fixed with nails, etc. complete all as specified and directed. |
| 10 | M&L for 2nd class hard wood clean sawn battern for tile at 30cm centres of sectional area exc 10Sqcm and n.exc 25Sqcm complete all as specified and directed. |
| 11 | S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with L-hook or cranked bolts complete all as specified and as directed. |
| 12 | S&F Plain Aluminium sheeting 0.71mm thick, Alloy 31000H4 in ridge, hips, valley gutter, drip and straight flashings complete all as specified and directed. |
| 13 | M&L for preparing and treating tiles battens any size and spacing with one coat of creosote (Measured overall on one side only spaces not deducted) complete all as specified and directed. |
| 14 | M&L for mangalore pattern roof tiles, interlocking at side joints, laid dry complete all as specified and as directed. |
| 15 | M&L for ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed. |
| 16 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 17 | S&F joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. confirming to Fe-290 (Gde E-165) (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed. |
| 18 | S&F roof trusses trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, tubular pipes or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 19 | M&L for preparation of new steel Surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of anti corrosive Epoxy paint over a coat of Epoxy primer, complete all as specified and directed. |
| 20 | Dismantling wall/floor tiling/ terrazo tile/ mosaic tiles/ pcc tiles incl. cement mortar bedding removing rubbish off the premises complete all as specified and directed. |
| 21 | M&L for light shade Virified Ceramic tiles light shade 8-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. over and including 15mm thick screed bed of CM 1:6 set and jointed in neat cement slurry and pointed in Epoxy joint filling and 3mm thick spacer width complete all as specified and directed. (Note: The epoxy joint filling shall be measured and paid seprately) |
| 22 | M&L for light shade vitrified ceramic tiles 8-10mm thick (square/rectangular) area of each tiles exceeding 0.42 Sqmbut not exceeding 1.00 Sqm as in vertical surfaces like skirtings, set and jointed in neat cement slurry and pointed in epoxy joint filling and 3mm thick spacer width to match over and including 10mm thick backing coat in cement mortar 1:3 complete all as specified and directed. (Note: The epoxy joint filling shall be measured and paid seprately) |
| 23 | M&L for preparation and complete removal of existing treatment and applying two coats of Oil bound distemper over a coat of 1.5 mm thick wall care putty and one coat of alkali resistant primer complete all as specified and directed.Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction. |
| 24 | M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two top coats of exterior anti fungal acrylic emulsion paint (Apex ultima protek (Asian paint) or its equivalentmake from the list of approved makes having FIVE years of performance warranty) over a coat of exterior water base coat all as specified and prescribed by manufacture of point and as directed at site by Engineer-in-Charge.Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of materials (like base coat/topcoat of exterior paint), labour & T&P wherever required for preparation of surface are demand to be included in the rates quoted. (ii)The work must be got executed through authorised applicator of manufacture. Guarantee certificate should provide from the authorised applicator of manufacturer and shall be got approved from GE. (iii)After carrying out preparation of surface the same shall be got approved before application of exterior emulsion for each building.(iv) The cost of Scaffolding and safety measures wherever required are deemed to be included in the rates quoted by the contractor |
| 25 | M&L for complete removal of old steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of anti corrosive Epoxy paint over a coat of Epoxy primer, over a coat of red oxide on steel surfaces complete all as specified and directed. |
| 26 | M&L for non - skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.38 sqm, in floors over and including cement screed 15 mm thick in CM 1:4 set and jointed in neat cement slurry and pointed in epoxy joint filling and 3mm thick spacer width complete all as specified and directed. (Note: The epoxy joint filling shall be measured and paid seprately) |
| 27 | M&L for glazed ceramic tiles in vertical surfaces, each tiles exceeding 0.18 sqm but not exceeding 1.00 sqm set and jointed in neat cement slurry and pointed in epoxy joint filling and 3mm thick spacer width to match including rendering 10 mm thick in CM 1:4 on fair face of brick work or concrte surfaces set and jointed complete all as specified and directed. (Note: The epoxy joint filling shall be measured and paid seprately) |
| 28 | M&L for epoxy tile joint filling using approved manufacturer on floor and walls complete as per the manufactures instructions complete all as specified and directed. |
| 29 | S&F in repair vitreous china WHB white with flat back of size 550x400mm with bracket including waste coupling and 32mm PVC waste pipe and 15mm bore Pillar taps,cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 30 | S&F in repair PVC flushing cistern low level 8 to 10 Ltr capacity of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as specified and directed. |
| 31 | S&F in repair vitreous china wash down water closet pan pedestal pattern white including fixing with trap including PVC matching seat cover complete all as specified and directed. |
| 32 | S&F in repair 600x450mm looking mirror of selected quality glass mounted on 6mm thick of commercial plywood and PVC moulding frame fancy type complete all as specified and directed. |
| 33 | S&F in repair stainless steel soap dish fixed to wall with screw complete all as specified and directed. |
| 34 | S&F in repair brass CP towel Rail 600mm long \\"D\\" type complete all as specified and directed. |
| 35 | S & F in repair vitreous china urinals, half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with PTMT Urinal spreader, grating and Union for discharge pipe complete all as specified and directed. |
| 36 | S&F in repair vitreous china urinal partition white of size 310x700 mm with Urinal partitions slabs terminating about 40cm above floor line, complete all as specified and directed. |
| 37 | Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 38 | M&L for 10mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 39 | M&L for two coats of oil bound distemper over a coat of 1.5mm thick wall care putty and one coat of alkali resistant primer to newly plastered surface including preparation of surfaces complete all as specified and directed. |
| 40 | M&L for cement Plaser in two coats, 8mm thick in CM 1:4 using liquid WPC over 12mm thick in CM (1:6) on external surfaces is to be finished even smooth with out using extra cement with using Approved WPC complete all as specified and as directed. (Note : WPC shall be meassured and paid seperately) |
| 41 | M&L for preparation of newly plastered surfaces of external wall and applying two coats of antifungal weather proof exterior paint over a coat of suitable primer, complete all as specified and as directed by the Engineer-In-Charge. Note:- Application of paint and primer shall be as per manufacturer's instruction. |
| 42 | Supply only Liquid water proofing compound complete all as specifoed and directed. |
| 43 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm and removing from site complete all as specified and directed. |
| 44 | All as item No.43 above but exc 1.50 Sqm and n.exc 4.00 Sqm each. |
| 45 | S&F IInd class hardwood plain solid straight chowkhat and frame wrought framed, rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 46 | S&F for MS work as in hold fast and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed. |
| 47 | M&L for PCC (1:3:6) type C-1 (Using 20mm graded stone aggregate) as in cills, copings, bed blocks for hold fasts and the like complete all as specified and directed. |
| 48 | S&F 35mm thick IInd Class hard wood rail and style, Plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003(Part I), kiln seasoned and chemically pressure treated as completed as specified. |
| 49 | S&F 35mm thick IInd Class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats as completed as specified. |
| 50 | M&L 35mm thick IInd class hardwood glazed and skeleton shutters , open rebated and prepared to receive glass gauge etc, edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of members of shutter as specified in SSR (Part-I)- 2009 complete all as specified and directed. |
| 51 | M&L for preparation of new surfaces of wood and wood based materials of any descriptions not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 52 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 53 | Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge. |
| 54 | S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 55 | S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed. |
| 56 | S&F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 57 | S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm each pane complete all as specified and directed. |
| 58 | S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 Sqm each pane complete all as specified and directed. |
| 59 | S&F for anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement. |
| 60 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 61 | S&F 100 mm long mild steel butt hinges medium weight complete all as specified and directed. |
| 62 | S&F 100 mm long SS butt hinges medium weight complete all as specified and directed. |
| 63 | S&F aluminum anodized barrel tower bolt 200mm long of extruded section complete all as specified and directed. |
| 64 | S&F aluminum anodized sliding door bolt 300mm long with hasp and staples (bolt type) and fixing clips of sheet cast of extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and directed. |
| 65 | S&F aluminum bow handle \\"D\\" type anodized 150mm long complete all as specified and directed. |
| 66 | S&F in repair MS helical door spring 300mm long including roller and roller plate complete all as specified and directed. |
| 67 | S&F 20mm dia stainless steel curtain rod including brackets complete all as specified and directed. |
| 68 | Dismantling wall and ceiling boards or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 69 | S&F aluminum snap grid false ceiling with grid 605x605mm size including hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40 x 3 mm size 60 mm long & expansion hold fastners 12.5 mm dia 40 mm long includng 4mm thick Non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with stainless steel screws complete all as specified and directed. |
| 70 | Demolition of cement concrete (unreinforced) above ground floors and paving exc. 15cm thickness (above ground level) complete all as specified and directed. |
| 71 | M&L for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed. |
| 72 | Demolition of brick work in cement mortar complete all as specified and directed. |
| 73 | M&L for precast cement concrete block masonry in type C1, 1:3:6 (20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in cement mortar 1:6 in wall complete all as specified and directed. |
| 74 | M&L for post constructional antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 75 | M&L for post constructional antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 76 | Providing and injecting chemical emulsion for post constructional antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed. |
| 77 | Excavating in post holes in soft/loose soil (or similar holes) each n.exc 0.5 cum, getting out ramming , filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm complete all as specified and directed. |
| 78 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed. |
| 79 | M&L for plain cement concrete 1:2:4, type B2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed. |
| 80 | M&L for rolled sections as in main pillars and cross beams, hip and jack rafters, purlins where connected to common rafters and fixed with angle cleats or other connecting plates of Fe 410-W Gde E-250 quality A complete all as specified and directed. |
| 81 | S&F prepainted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 82 | S&F suspended false ceiling consisiting of 12mm thick Gypsum seamless board suspended on GI frame work with staggered joints, GI frame work to consist GI perimeter channel 25mm x20mm of 22 gauge along perimeter of false ceiling. Channel section of 50x25mm of 22 gauge and at 300mm C/C throughout one way fixed with Serew/nut bolt and other direction 40 x 15mm x 22 gauge channel provided for interlocking with GI cleat and expansion fasteners including hangers 6mm dia G.I. fixed to roof truss, Boards are to be joined and finished so as to have a flush look which includes finishing the tapered and square edges of the gypsum board with joining compound paper tape and two coat plastic emulsion paint over one coats of primer & one layer putty 1.5mm thick suitable for gypsum board (As per the recommendation s/ practice) including necessary scaf folding and shuttering complete as directed as specified and directed by Engr-in-Charge. |
| 83 | S&F 150 mm dia of half round or 180 mm width rectangular PVC SWR ready made eaves gutter of pressure rating 6 Kg/cm2 of approved make including necessary fitting like bend WC/MS clips etc complete all as specified and directed. |
| 84 | S&F 150MM dia of PVC (SWR) pipe single socketed in any length with rubber joints including necessary fitting like bend WC/MS clips etc fixed on walls complete all as specified and directed. |
| 85 | S&F in repair CPVC pipes 25 mm outter dia high pressure SDR 13.5 & Plain CPVC SDR 11 fittings in trenches/ on wall complete including all necessary fittings, solvents, complete all as specified and directed. |
| 86 | S&F in repair CPVC pipes 20 mm outter dia high pressure SDR 13.5 & Plain CPVC SDR 11 fittings in trenches/ on wall complete including all necessary fittings, solvents, complete all as specified and directed. |
| 87 | S&F in repair 2000 litres capacity Rotational Moulded Polyethylene Water Storage Tanks, 4 layered white (Cylindrical, vertical with closed top), hoisted & fixed in position, complete all as specified and as directed. |
| 88 | Supply and fix in repair of 25mm dia. CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed. |
| 89 | S&F 15 mm angle valve, half turn with flange, chromium plated for fixing with CPVC pipe and taking down old one, complete specified and as directed. |
| 90 | S&F in repair concealed stop cock regular body,Quarter turn with adjustable wall flange chromium plated with CP cup fancy type of size 20mm complete all as specified and as directed by the Engineer-in-charge.Make : CERA Model NO: F2006351, F4050102 or its equivalent make as per the approved list of manufactures |
| 91 | S&F in repair of 15mm size Swivel Overhead Shower (minimum weight 40 grams) of PTMT, any colour with shower arm (minimum weight 40 grams) 195mm long with bend of 45 degree with flange, fixing with CPVC Pipe, complete all as specified and as directed .Make : CERA Model No. F 7020104 or its equivalent make as per the approved list of manufactures |
| 92 | S&F in repair of 450mm long, 15mm dia. PVC Connection with brass union on both sides to suit 15mm GI pipe, complete all as specified and directed. |
| 93 | S&F in repair of health faucet, ABS body with wall hook and one metre SS braided rubber hose pipe, complete all as per specified and directed.Make : CERA Model No. F 8030102 or its equivalent make as per the approved list of manufactures |
| 94 | S&F in repair pillar taps, swan neck spout with aerator, cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed for 15mm bore pipe complete all as specified and as directed. |
| 95 | S&F in repair 15mm size Chromium Plated fancy type Bib Cock, quarter turn with flange and aerator, short body, cast copper alloy with crutch or butterfly handle, screwed for GI/ CPVC pipe, complete all as specified and as directed by the Engineer in Charge.Make : Cera Cat. Part No. F2014151 or its equivalent make as per the approved list of manufactures |
| 96 | S&F in repair chromium plated cast copper alloy Kitchen Sink Cock, quarter turn, wall mounted with swivel spout not less than 150 mm and wall flange complete all as specified and as directed.Make : Model No.F1018251 of CERA or its equivalent make as per the approved list of manufactures |
| 97 | M&L for cutting chases on walls, floors etc. not exceeding 10 cm girth and making good the disturbed surface to match with the existing surface after removing the existing concealed pipe/ laying new pipe, complete all as specified and directed by the Engineer in Charge. |
| 98 | Taking down carefully existig copper / aluminium point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed. |
| 99 | Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity all as specified and directed. |
| 100 | Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified |
| 101 | Material and Labour of point wiring with 1.5 Sqmm PVC insulated sheathed FRLS multistranded single core copper conductor cable in PVC concealed conduit rigid non metalic (ISI marked) fixed concealed on wall/ roof except beam, column and RCC roof including cutting chases incl suitable size/ cap of sunken box for modular switch and socket and modular white cover plate, flush metal box etc including 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. |
| 102 | All as per item No 101 here in before but One fan point controlled by one push button on independent board. |
| 103 | All as per item No 101 here in before but One 3 pin 5 Amp socket outlet point controlled by one switch on same board. |
| 104 | All as per item No 101 here in before but One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board. |
| 105 | All as per item No.101 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable. |
| 106 | S&F switch modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed.Make Legrand Cat ref. 5734 00 or its equivalent make as per the approved list of manufactures |
| 107 | S&F socket outlet modular type 6A - 2 in 1,without shutter, 2 module, duly ISI marked, complete all as specified and directed. Make : Legrand Cat ref. 5734 02 or its equivalent make as per the approved list of manufactures |
| 108 | S&F switch modular type 16 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make : Legrand Cat ref. 5734 10 or its equivalent make as per the approved list of manufactures |
| 109 | S&F socket outlet modular type 16A, 3/5 pin combined, 2 module, duly ISI marked, complete all as specified and directed. Make Legrand Cat ref. 5734 71 or its equivalent make as per the approved list of manufactures |
| 110 | S&F in repair ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed. |
| 111 | S&F ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed. |
| 112 | S&F in replacement for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 113 | S&F in replacement rotary Stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 2 module, 120W, white in colour, duly ISI marked complete all as specified and directed. Make : Legrand Cat ref. 5734 16 or its equivalent make as per the approved list of manufactures |
| 114 | S&F rotary Stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 2 module, 120W, white in colour, duly ISI marked complete all as specified and directed. Make : Legrand Cat ref. 5734 16 or its equivalent make as per the approved list of manufactures |
| 115 | S&F in replacement TV socket 1 module, RJ11 including taking down.complete all as specified and directed. Make : Legrand Cat ref. 5734 26 or its equivalent make as per the approved list of manufactures |
| 116 | S&F in replacement Internet socket, RJ45, 2 module including taking down.complete all as specified and directed. Make : Legrand Cat ref. 6794 65 or its equivalent make as per the approved list of manufactures |
| 117 | S&F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Philips Cat Part No. BN100C LED20S-6500 PSU L120 GR S4 or its equivalent make as per the approved list of manufactures |
| 118 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified. Make: Philips Cat part no - RC780X LED12S-6500 PSU W5L56 OD WH or its equivalent make as per the approved list of manufactures |
| 119 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, min 120 lum/watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. all as specified and directed. Make: Philips Cat Part no - RC370B LED36S-6500 G6 L60W60 PSU OD V3 or its equivalent make as per the approved list of manufactures |
| 120 | S&F in replacement bed side Lamp 7 watt , min 120 lum/watt, 50 hz,230 volts,3000k with all accessories and connection to the electric circuit complete all as specified.Make Philips Cat Part no - 48042 or its equivalent make as per the approved list of manufactures |
| 121 | S&F in replacement LED building security light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete. Make: Crompton Cat Part No. LSTS-45-CDL-M or its equivalent make as per the approved list of manufactures |
| 122 | S&F in replacement of LED building security light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete. Make: Crompton Cat Part No. LSTS-45-CDL-M or its equivalent make as per the approved list of manufactures |
| 123 | S&F in replacement LED ‘T’ type retrofit fitting 14 Watt, 6500-7500K, Min 120 Lumen/Watt maximum output 1400 lumen, with polycarbonate material complete all as specified and as directed. Make : Philips Cat Part No.TLL-14W-6500K-B22 or its equivalent make as per the approved list of manufactures |
| 124 | S&F in replacement down rod, suitably threaded and holed, made out of 15 mm dia GI tube heavy grade, duly painted, 2' long, suitable for ceiling fan any type, any make, any size including taking down old unserviceable down rod complete all as specified and directed. |
| 125 | Material and Labour for replacement of hanging hook for ceiling fan, made out of mild steel round bar not less than 15 mm thick, fixed to ceiling with suitable MS base plate, nuts, bolts, and washers. The assembly shall be securely anchored to the structural member to safely bear the load of the fan. The work includes fabrication, drilling, fixing in position, and painting of all exposed metal surfaces with one coat of red oxide primer and two coats of synthetic enamel paint, complete all as specified and directed. |
| 126 | S&F in replacement ceiling fan, complete with blades, down rods, accessories 230V, 1200mm sweep, with min air delivery 235 CFM with service value 6.7 BEE,35 Watt, five star rated with brushless direct current (BLDC) including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to ceilng fan of required length giving connection complete all as specified. Make: Orient Model. I-falcon Deco BLDC ceiling fan/ Polar Model.Efisavy Anti-Dust ceiling fan/ Khaitan Model.Passion high-speed ceiling fan Note : Old ceiling fans shall be deposited at AGE E/M (NW) store yard. |
| 127 | S&F in replacement of exhaust fan plastic body heavy duty with louvers complete of sweep size 250mm, 1200 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including suitable size of cutting/opening the wall for fixing and provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan of required length giving connection complete all as specified.Note : Old fans shall be deposited at AGE E/M (NW) store yard.Make : Orient Cat ref.Ventilator DX or its equivalent make as per the approved list of manufactures |
| 128 | S&F in replacement exhaust fan steel body heavy duty with louvers complete of sweep size 300 mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including suitable size of cutting/opening the wall for fixing and provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan of required length for giving connection complete all as specified. Note : Old fans to be deposit at AGE E/M (NW) store yard.Make : Orient Cat ref.Air Flow or its equivalent makes from the approved list of makes) |
| 129 | S&F in replacement factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door TPN distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 415V, 50Hz supply, TPN DB, IP-43 protection, partly immersed in wall, and without MCB's including making good distrubbed surfaces with matching colour, complete all as specified and directed by Engineer-in-Charge. Make Legrand Cat Part No. 5076 70 or its equivalent make as per the approved list of manufactures |
| 130 | S&F in replacement RCCB SPN, 32A - 40 Amps, 240 volts, \\"C\\" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified.Make: Legrand Cat Part No.4113 26 or its equivalent make as per the approved list of manufactures |
| 131 | S&F in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.Make: Legrand Cat Part No.4085 95 or its equivalent make as per the approved list of manufactures |
| 132 | S&F in replacement meter box enclosure suitable for 6-32 amp three phase 415 volt complete all as specified and directed.Make :L&T Cat part No. CM91003OOOO or its equivalent make as per the approved list of manufactures |
| 133 | S&F in replacement SS enclosure suitable for MCCB 100-200 amp complete all as specified and directed.Make Legrand Cat ref. 5078 06 or its equivalent make as per the approved list of manufactures |
| 134 | S&F in replacement MCCB FP, 63 Amps, 415 volts,rated service short circuit breaking capacity Ics= Icu at 415V ,36 KA duly ISI marked, in DB, complete with connection testing and commissioning all as specified.Make:L&T Cat Part No.4200 90 or its equivalent make as per the approved list of manufactures |
| 135 | S&F in replacement sub main wiring with 2 runs of 2.5 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC conduits and all accessories, with 1 run of 2.5 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc all as specified.Note:- Three run of cable and one run of PVC conduits shall be measured as one unit. |
| 136 | Supply and laying in replacement XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 35 sq.mm 4 core complete all as specified. |
| 137 | Material and Labour for earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. Provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. Excavation in soft/ loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009) complete all as specified. |
| 138 | S&F in replacement DX3 timer switch for building security light 230V, 50 Hz supply complete all as specified and directed.Make :Legrand Cat Part No.0037 10 or its equivalent make as per the approved list of manufactures |
| 139 | M&L for air termination, single pointed aluminium rod 12mm dia and 300mm long including taking down old unserviceable one complete all as specified and directed. |
| 140 | M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down old unserviceable one complete all as specified and directed. |
| 141 | M&L for GI strip 32x6mm buried directly in ground or fixed to walls including taking down old unserviceable one complete all as specified and directed. |
| 142 | M&L for test point terminal block made of gun metal or phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head screw for fixing the same on wall, including suitable size of coverd MS box of 1.5mm thick including taking down old unserviceable one complete all as specified and directed. |
| 143 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers all around top and bottom and electrode connection by using galvanised iron earth lead strip of size 32 x 6mm flat iron by means of bolts, nuts, check nut and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe 40mm bore protection pipe light grade for protection strip upto 3m above ground level (Up to the test points) PCC chambeer in cement concrete (1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion:-(a) The unit rate shall include for protection pipe, GI water pipe, funnel, wire mesh excavation, RCC pit cover, test point, 32x6mm galvanised strip from top of earth plate upto 5mtr above GL anf if GI protection is less than 5m, no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc. shall be deemed to be included in the unit rate. (c) If the testing result of earth Wk is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on the account. (d) Earthing work will be carried out in presence of MES representative. |
| 144 | S&F SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, complete all as specified and as directed |
| 145 | S&F round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as per specified and directed. Make Philips Cat Part No. SM251/261 LED16S 6500 PSU WH or its equivalent make as per the approved list of manufactures |
| 146 | S&F recessed mounted LED high bay light flood type, water proof, 100 Watt, IP-65 protection 120 Lumen/Watt, 240 Volt all as per specified and directed. Make Philips Cat Part No. BY515P LED 150S 5700 PSU GR or its equivalent make as per the approved list of manufactures |
| 147 | S&F recessed mounted LED high bay light flood type, water proof, 10 Watt, IP-65 protection 120 Lumen/Watt, 240 Volt all as per specified and directed. |
| 148 | S&F ceiling fans, complete with blades, down rods, accessories 230V, 1200mm sweep, with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current (BLDC) including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to ceiling fan of required length f for giving connection complete all as specified and directed. Note: Orient Model. I-falcon Deco BLDC Ceiling Fan/ Polar Model.Efisavy Anti-Dust Ceiling fan/ Khaitan Model.Passion high-speed Ceiling fan |
| 149 | S&F pedestal Fans, metallic body 450 mm sweep Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. Make: Orient Cat ref. Tornado II or its equivalent makes from the approved list of manufactures |
| 150 | S&F wall Mounted fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting.Make: Orient Cat ref. Thunderstorm Pro or its equivalent makes from the approved list of manufactures |
| 151 | S&F sheet metal enclosure Vertical TPN for DB's when MCCB's to be used 6 way with 250 amps bus bar double door IP 43 metal door complete all as specified and as directed. Make L&T cat No DBVTL006DD or its equivalent makes from the approved list of manufactures |
| 152 | S&F MCCB four pole 160 Amps, 415 Volts, with breaking capacity 36 KA complete all as specified and directed. |
| 153 | S&F MCB SP, 6A-40 Amps, 240 volts, \\"C\\" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning all as specified. |
| 154 | S&F PVC Junction box, with 2 x Aluminium busbar and one MCB SP 6 Amps for controlling street/ security lights water tight complete all as specified and as directed. |
| 155 | S&F street light control panel, three phase 6 KW load with 24 hour Digital timer, Contactor rating 32 Amps TP, MCB rating 40 Amps TPN complete all as specified and as directed. Make : Havells Cat Part No. IHXTS03060 or its equivalent makes from the approved list of manufactures |
| 156 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender