Tender For Installation Of 25 Kwp Off Grid Solar Power Plant At 15 Bops Of 199 Bn And 179 Bn (Now 124 Bn Bsf) Of Shq Panisagar Under Ftr Hq Tripura. (Sh : Provision Of Separate Distribution Of Power Load Of Solar Power Plant And Repair/Maint Of Exist
Tender Overview
Project Description
Tender for Installation Of 25 Kwp Off Grid Solar Power Plant At 15 Bops Of 199 Bn And 179 Bn (Now 124 Bn Bsf) Of Shq Panisagar Under Ftr Hq Tripura. (Sh : Provision Of Separate Distribution Of Power Load Of Solar Power Plant And Repair/Maint Of Existing Gen Room For Use As Control Room Of Solar Power Plant At Various Bops Of 199 Bn Bsf Under Shq Bsf Panisagar)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/ HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (iii) 2 X 4 sq mm + 1 X 4 sq mm earth wire |
| 2 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connection, painting etc. as required. |
| 3 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connection, testing and commissioning etc. as required. |
| 4 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 5 | Supplying and fixing of PVC insulated and PVC sheathed Aluminium conductor power cable of 1.1 KV grade of 2 X 16 sqmm size on existing wall surface with saddle/clamp. Make-Havells/Polycab/Finolex/KEI |
| 6 | Supplying and laying of PVC insulated and PVC sheathed Aluminium conductor power cable of 1.1 KV grade of 2 X 16 sqmm size in the existing RCC/ HUME/ METAL pipe/DWC pipe as required.Make-Havells/Polycab/Finolex/KEI |
| 7 | Supplying and laying of PVC insulated and PVC sheathed Aluminium conductor power cable of 1.1 KV grade of 2 X 16 sqmm size as loop .Make-Havells/Polycab/Finolex/KEI |
| 8 | Providing and fixing of 63 Amp TPN busbar chamber with SS enclosure on existing wall surface including connection etc requried Make Indoaisan or equivalent to Havells/Schneider/Legrand etc. |
| 9 | Supplying & laying of one number PVC insulated and PVC sheathed Armoured / XLPE power aluminium conductor cable of 1.1 KV grade of size 3.5 x 25 sqmm, direct in ground in the trench in one tier horizontal formation including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering Conf. to IS:7098 part - I (make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T) |
| 10 | Supplying & laying of one number XLPE insulated and PVC sheathed Armoured power cable of 1.1 KV grade of size 3.5 x 25 sq mm in the existing RCC/ HUME/ METAL pipe/surface as required Conf. to IS:7098 part - I of ( make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T) |
| 11 | S/I/T/C of outdoor type joint box, made out of 16 SWG CRCA sheet duly primed & painted with synthetic enamel black paint of size 450 mm (height) x 450 mm (width) x 300 mm deep having 200 amps, 04 nos insulated aluminium bus bars and suitable size insulator, & angle iron frame of base size 450 mm x 300 mm with 600 mm long legs made out of 45 mm x 45 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, etc. as required As per direction of Engineer Incharge. |
| 12 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group B) |
| 13 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed m,edium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 14 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 15 | Supplying and fixing 5/6 amps switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 16 | Supplying and fixing of 3 pin 5/6 Amp. Socket outlet Piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 18 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. |
| 19 | Earthing with GI earth pipe 4.5 metre long x 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required |
| 20 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 21 | Providing installation testing and commissioning of ISI marked ceiling fans of 1200 mm sweep, single phase, AC 230 Volt, 50Hz supply. ., capacitor type with double ball bearing complete with capacitor, 300 mm down rod, canopies,with 1.5 sqmm FR PVC indulsted, copper conductor, single core cable etc. as required. (Make- Usha/Bajaj/Crompton/Havells) |
| 22 | Supplying,installation,testing & commissioning of 20 watt LED batten tube light fitting suitable for single phase AC complete with connection etc as required. (Make - Havells/Bajaj/Crompton) |
| 23 | Supplying and fixing of 300 mm sweep, metalic exhaust fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing opening including making hole to suit the size & S/F of louver / shutter including connections etc. as required. (Make- Havells/Standard/Usha/Bajaj/ Crompton). |
| 24 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) |
| 26 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 27 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 28 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 29 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 30 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) |
| 31 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 32 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 33 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : : 3 mm thick |
| 34 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 35 | correction Factor on DSR 2023 item Srl No 24 to 34 on account of GST @ 0.973 (w.r.t CPWD OM No. 158/SE(TAS) /GST/ 2024/ 02-E dated 08/08/2024 |
| 36 | Add @ 56 % Cost Index on DSR 2023 item Srl No 24 to 34 Rs. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender